Summary
PRCOM20132504
Building Permit - Commercial
Certificate of Occupancy
LE GRAND APARTMENTS LLC
CHANGE OF TENANT
TENANT FINISH
11/14/2013
12/17/2013
06/08/2014
01/07/2014
Locations
Contacts
DOUGLAS LANDSCAPE & DESIGN LLC, Address:1713 NE WHITESTONE DR, Phone:(816) 927-5906  
MD REPAIR, Address:7901 S PARRENT RD, Phone:(816) 690-7985  
CROSS ELECTRIC INC, Address:18705 E HIGHLAND DR, Phone:(816) 540-2452  
AGMP ARCHITECTS, Address:1119 NE CLUBHOUSE CIR, Phone:(816) 525-8918  
LE GRAND APARTMENTS LLC, Address:25706 E SHADYBROOK LN  
LRW PLUMBING LLC, Address:20631 W 319TH ST, Phone:(913) 568-7737  
Reviews
Review Type Outcome Est. Completion Date Completed
Licensed Contractors Approved 06/08/2014 12/17/2013
Codes Admin
License contractors
Corrective Action Required
11/25/2013

No person, other than a licensed contractor or employees of a licensed contractor, shall engage in electrical, plumbing or mechanical business, construction, installation or maintenance unless duly licensed in accordance with this section. Expert from Sec. 7-130, Lees Summit Code of Ordinances. Action required - Provide the names of the licensed electrical and mechanical contractors. This information is required for permit approval.
Fire Plan Review Approved with Conditions 12/19/2013 12/17/2013
Brian Austerman
Misc
Corrective Action Required
12/12/2013

Show ratings of separation walls between adjoining occupancies. There is a 2 hour fire separation requirement for this occupancy, or show the occupant load for the entire FIRE AREA without separations. 12/5/2013 Rating of the south wall is shown as a 2 hour existing wall. The north wall is shown as a 1 hour wall. Condition is approved with the condition that a 2 hour wall may be required after review for a new tenant in the vacant spaces north of this occupancy. See letter from Mark Dunning dated 12/5/2013.
Misc
Corrective Action Required
12/12/2013

Provide clarification on calculated occupancy. Under "Interior Finish Ratings" it shows the occupancy as 142 but under "Occupancy Tables" it is listed as 98. Approved
Misc
Corrective Action Required
12/17/2013

No additional FD comments
Building Plan Review Approved with Conditions 12/19/2013 12/16/2013
Mike Weisenborn
Plumb - Minimum number of fixtures
Resolved
12/16/2013

2006 IPC 403.1 - Minimum number of fixtures. Plumbing fixtures shall be provided for the type of occupancy and in the minimum number shown in Table 403.1. Types of occupancies not shown in Table 403.1 shall be considered individually by the code official. The number of occupants shall be determined by the International Building Code. Occupancy classification shall be determined in accordance with the International Building Code. Action required - Show compliance with this requirement based on the calculated occupant load. Mike Weisenborn 12/09/2013 3:50 PM - As a drinking fountain is not shown on the plans, I assume that a bottled water system will be provided. Indicate this on the plans. Mike Weisenborn 12/16/2013 11:11 AM - Bottled water has been added.
Bldg - Means of egress illumination - Emergency power
Informational
12/16/2013

2006 IBC 1006.3 - Illumination emergency power. The power supply for means of egress illumination shall normally be provided by the premises electrical supply. In the event of power supply failure, an emergency electrical system shall automatically illuminate the following areas. 1. Aisles and unenclosed egress stairways in rooms and spaces that require two or more means of egress. 2. Corridors, exit enclosures and exit passageways in building required to have two or more exits. 3. Exterior egress components at other than the level of exit discharge until exit discharge is accomplished for buildings required to have two or more exits. 4. Interior exit discharge elements, as permitted in Section 1024.1, in buildings required to have two or more exits. 5. Exterior landings, as required by Section 1008.1.5, for exit discharge doorways in building required to have two or more exits. The emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or an on-site generator. The installation of the emergency power system shall be in accordance with Section 2702. Action required - Compliance to be verified on inspection.
Accessibility - Water closet - Clearance around
Resolved
12/16/2013

ICC/ANSI A117.1 2003 604.3.1 - Size. A clearance around a water closet 60 inches minimum, measured perpendicular from the sidewall, and 56 inches minimum, measured perpendicular from the rear wall, shall be provided. Action required - This requirement is not being met in the added womens restroom. Make needed corrections. Mike Weisenborn 12/16/2013 11:11 AM - Corrections have been made.
Misc
Resolved
12/16/2013

Plumbing specifications have not been provided. Action required - Provide additional information. Mike Weisenborn 12/16/2013 11:12 AM - Additional information has been added to the plans.
Misc
Resolved
12/16/2013

2006 IPC - Section 303.3 - Prohibited locations. Fuel-fired appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces: 1. Sleeping rooms. 2. Bathrooms. 3. Toilet rooms. 4. Storage closets. 5. Surgical rooms. Action required - Verify that FCU 1 and 2 are not pulling combustion air from the restroom. Mike Weisenborn 12/16/2013 11:12 AM - Compliance to be verified on inspection.
Misc
Resolved
12/16/2013

Sheet TF-1 indicates that the south restroom off of the multi-purpose room is existing and Sheet MP-1 indicates that the fixtures in this room are to be added. Action required - I believe your arrows are going to the wrong fixtures. Make needed corrections. Mike Weisenborn 12/16/2013 11:13 AM - Corrections have been made.
Building Plan Review Rejected 12/11/2013 12/10/2013
Mike Weisenborn
Bldg - Occupant load calculations - Areas without fixed seats
Resolved
12/09/2013

2006 IBC 1004.1.1 - Areas without fixed seating. The number of occupants shall be computed at the rate of one occupant per unit of area as prescribed in Table 1004.1.1. For areas with out fixed seating, the occupant load shall not be less than that number determined by dividing the floor area under consideration by the occupant per unit of area factor assigned to the occupancy as set forth in Table 1004.1.1. Where an intended use is not listed in Table 1004.1.1, the building official shall establish a use based on a listed use that most nearly resembles the intended use. Action required - The plans provide multiple occupant loads but no calculations to substantiate any of them. Provide calculations and an occupant load for the space. Mike Weisenborn 12/09/2013 12:28 PM - Corrections have been made.
Plumb - Minimum number of fixtures
Corrective Action Required
12/04/2013

2006 IPC 403.1 - Minimum number of fixtures. Plumbing fixtures shall be provided for the type of occupancy and in the minimum number shown in Table 403.1. Types of occupancies not shown in Table 403.1 shall be considered individually by the code official. The number of occupants shall be determined by the International Building Code. Occupancy classification shall be determined in accordance with the International Building Code. Action required - Show compliance with this requirement based on the calculated occupant load. Mike Weisenborn 12/09/2013 3:50 PM - As a drinking fountain is not shown on the plans, I assume that a bottled water system will be provided. Indicate this on the plans.
Mech - Outdoor air required
Resolved
12/09/2013

2006 IMC 403.2 - Outdoor air required. The minimum ventilation of outdoor air shall be determined in accordance with Section 403.3. Exception: Where the registered design professional demonstrates that an engineered ventilation system design will prevent the maximum concentration of contaminants from exceeding the obtainable by the rate of outdoor air ventilation determined in accordance with Section 403.3, the minimum required rate of outdoor air shall be reduced in accordance with such engineered system design. Action required - The table provided is not calculated per this section and does not include the entire space. Make needed corrections. Mike Weisenborn 12/09/2013 3:52 PM - The table has been altered.
Misc
Resolved
12/09/2013

The hardware type for doors 10 and 13 is not shown on the door schedule. Action required - Provide hardware information for thiese doors. It appears that the door identifiers have been changed. Make corrections to the table as needed. Mike Weisenborn 12/09/2013 3:51 PM - Corrections have been made.
Bldg - Means of egress illumination - Emergency power
Corrective Action Required
12/04/2013

2006 IBC 1006.3 - Illumination emergency power. The power supply for means of egress illumination shall normally be provided by the premises electrical supply. In the event of power supply failure, an emergency electrical system shall automatically illuminate the following areas. 1. Aisles and unenclosed egress stairways in rooms and spaces that require two or more means of egress. 2. Corridors, exit enclosures and exit passageways in building required to have two or more exits. 3. Exterior egress components at other than the level of exit discharge until exit discharge is accomplished for buildings required to have two or more exits. 4. Interior exit discharge elements, as permitted in Section 1024.1, in buildings required to have two or more exits. 5. Exterior landings, as required by Section 1008.1.5, for exit discharge doorways in building required to have two or more exits. The emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or an on-site generator. The installation of the emergency power system shall be in accordance with Section 2702. Action required - Compliance to be verified on inspection.
Accessibility - Water closet - Clearance around
Corrective Action Required
12/09/2013

ICC/ANSI A117.1 2003 604.3.1 - Size. A clearance around a water closet 60 inches minimum, measured perpendicular from the sidewall, and 56 inches minimum, measured perpendicular from the rear wall, shall be provided. Action required - This requirement is not being met in the added womens restroom. Make needed corrections.
Misc
Corrective Action Required
12/09/2013

Plumbing specifications have not been provided. Action required - Provide additional information.
Misc
Corrective Action Required
12/09/2013

2006 IPC - Section 303.3 - Prohibited locations. Fuel-fired appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces: 1. Sleeping rooms. 2. Bathrooms. 3. Toilet rooms. 4. Storage closets. 5. Surgical rooms. Action required - Verify that FCU 1 and 2 are not pulling combustion air from the restroom.
Misc
Corrective Action Required
12/10/2013

Sheet TF-1 indicates that the south restroom off of the multi-purpose room is existing and Sheet MP-1 indicates that the fixtures in this room are to be added. Action required - I believe your arrows are going to the wrong fixtures. Make needed corrections.
Fire Plan Review Approved with Conditions 12/11/2013 12/05/2013
Brian Austerman
Misc
Corrective Action Required
12/04/2013

Show ratings of separation walls between adjoining occupancies. There is a 2 hour fire separation requirement for this occupancy, or show the occupant load for the entire FIRE AREA without separations. 12/5/2013 Rating of the south wall is shown as a 2 hour existing wall. The north wall is shown as a 1 hour wall. Condition is approved with the condition that a 2 hour wall may be required after review for a new tenant in the vacant spaces north of this occupancy. See letter from Mark Dunning dated 12/5/2013.
Misc
Corrective Action Required
12/04/2013

Provide clarification on calculated occupancy. Under "Interior Finish Ratings" it shows the occupancy as 142 but under "Occupancy Tables" it is listed as 98. Approved
Building Plan Review Rejected 11/26/2013 11/26/2013
Mike Weisenborn
Bldg - Occupant load calculations - Areas without fixed seats
Corrective Action Required
11/25/2013

2006 IBC 1004.1.1 - Areas without fixed seating. The number of occupants shall be computed at the rate of one occupant per unit of area as prescribed in Table 1004.1.1. For areas with out fixed seating, the occupant load shall not be less than that number determined by dividing the floor area under consideration by the occupant per unit of area factor assigned to the occupancy as set forth in Table 1004.1.1. Where an intended use is not listed in Table 1004.1.1, the building official shall establish a use based on a listed use that most nearly resembles the intended use. Action required - The plans provide multiple occupant loads but no calculations to substantiate any of them. Provide calculations and an occupant load for the space.
Plumb - Minimum number of fixtures
Corrective Action Required
11/25/2013

2006 IPC 403.1 - Minimum number of fixtures. Plumbing fixtures shall be provided for the type of occupancy and in the minimum number shown in Table 403.1. Types of occupancies not shown in Table 403.1 shall be considered individually by the code official. The number of occupants shall be determined by the International Building Code. Occupancy classification shall be determined in accordance with the International Building Code. Action required - Show compliance with this requirement based on the calculated occupant load.
Mech - Outdoor air required
Corrective Action Required
11/25/2013

2006 IMC 403.2 - Outdoor air required. The minimum ventilation of outdoor air shall be determined in accordance with Section 403.3. Exception: Where the registered design professional demonstrates that an engineered ventilation system design will prevent the maximum concentration of contaminants from exceeding the obtainable by the rate of outdoor air ventilation determined in accordance with Section 403.3, the minimum required rate of outdoor air shall be reduced in accordance with such engineered system design. Action required - The table provided is not calculated per this section and does not include the entire space. Make needed corrections.
Misc
Corrective Action Required
11/25/2013

The hardware type for doors 10 and 13 is not shown on the door schedule. Action required - Provide hardware information for thiese doors. It appears that the door identifiers have been changed. Make corrections to the table as needed.
Bldg - Means of egress illumination - Emergency power
Corrective Action Required
11/25/2013

2006 IBC 1006.3 - Illumination emergency power. The power supply for means of egress illumination shall normally be provided by the premises electrical supply. In the event of power supply failure, an emergency electrical system shall automatically illuminate the following areas. 1. Aisles and unenclosed egress stairways in rooms and spaces that require two or more means of egress. 2. Corridors, exit enclosures and exit passageways in building required to have two or more exits. 3. Exterior egress components at other than the level of exit discharge until exit discharge is accomplished for buildings required to have two or more exits. 4. Interior exit discharge elements, as permitted in Section 1024.1, in buildings required to have two or more exits. 5. Exterior landings, as required by Section 1008.1.5, for exit discharge doorways in building required to have two or more exits. The emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or an on-site generator. The installation of the emergency power system shall be in accordance with Section 2702. Action required - Compliance to be verified on inspection.
Fire Plan Review Rejected 11/26/2013 11/21/2013
Brian Austerman
Misc
Corrective Action Required
11/21/2013

Show ratings of separation walls between adjoining occupancies. There is a 2 hour fire separation requirement for this occupancy, or show the occupant load for the entire FIRE AREA without separations.
Misc
Corrective Action Required
11/21/2013

Provide clarification on calculated occupancy. Under "Interior Finish Ratings" it shows the occupancy as 142 but under "Occupancy Tables" it is listed as 98.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for Change of Tenant $30.00 $30.00 Paid 12/17/2013
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
All Rough Inspection - Commercial Failed 12/18/2013 12/18/2013 at 12:00 AM 12/18/2013
Misc
Corrective Action Required
12/18/2013
-MAKE UP JUNCTION BOXES -SECURE MC WITHIN 6 INCHES OF THE BOX
All Rough Inspection - Commercial Passed 12/20/2013 (8:00 to 5:00) 12/20/2013 at 12:00 AM 12/20/2013
Misc
Corrective Action Required
12/18/2013
-MAKE UP JUNCTION BOXES -SECURE MC WITHIN 6 INCHES OF THE BOX
Occupancy Inspection - Codes Commercial Failed 1/6/2014 1/6/2014 at 12:00 AM 01/06/2014
Misc
Corrective Action Required
01/06/2014
-INSTALL COMBUSTION AIR OPENINGS FOR MECHANICAL ROOM 24x6 WITHIN 12 INCHES FROM THE BOTTOM OF THE ROOM AND 12" INCHES FROM THE TOP -REPAIR LIGHT NORTH SIDE OF MULTI PURPOSE ROOM -POST OCCUPANT LOAD AT ENTRANCE TO MULTI PURPOSE ASSEMBLY AREA
Occupancy Inspection - Fire Passed 1/6/2014 at 12:00 AM 01/07/2014
Occupancy Inspection - Codes Commercial Full C of O 1/7/2014 1/7/2014 at 12:00 AM 01/07/2014
Misc
Resolved
01/07/2014
-INSTALL COMBUSTION AIR OPENINGS FOR MECHANICAL ROOM 24x6 WITHIN 12 INCHES FROM THE BOTTOM OF THE ROOM AND 12" INCHES FROM THE TOP -REPAIR LIGHT NORTH SIDE OF MULTI PURPOSE ROOM -POST OCCUPANT LOAD AT ENTRANCE TO MULTI PURPOSE ASSEMBLY AREA
Documents & Images
Date Uploaded File Type Document Name
11/21/2013 Letter Fire Building Plan Review
11/26/2013 Letter Codes Plan Review Conditions
12/05/2013 Letter Fire Building Plan Review
12/10/2013 Letter Codes Plan Review Conditions
12/17/2013 Letter Fire Building Plan Review
12/17/2013 Letter Codes Building Permit
12/17/2013 Letter Codes Plan Review Conditions
12/18/2013 Letter Inspection Summary
12/20/2013 Letter Inspection Summary
01/06/2014 Letter Inspection Summary
01/07/2014 Letter Field Certificate of Occupancy
01/08/2014 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home