Permit Application Status

PRCOM20122641


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRCOM20122641
Building Permit - Commercial
Certificate of Occupancy
MMHK LLC
ALTERATION COMMERCIAL
KITCHEN EQUIPMENT, INSTALL A MECHANICAL HOOD OVER STOVE GRILL, INSTALL THREE COMPARTMENT SINK, REMOVE A COUPLE NON-BEARING WALLS, CONSTRUCT A COUPLE NON-BEARING WALLS (SEE DRAWING). NO NEW ELECTRICAL JUST SWITCHING OUT FIXTURES.
11/30/2012
05/24/2013
10/16/2013
09/12/2013
Locations
Contacts
MMHK LLC, Address:1511 NE COLBERN RD  
SALADINO PLUMBING & HEATING COMPANY, Address:2210 TELEVISION PL, Phone:(816) 833-9900  
SALADINO PLUMBING & HEATING COMPANY, Address:2210 TELEVISION PL, Phone:(816) 833-9900  
Tammy Tyner, Address:1715 NE LAKESHORE DRIVE, Phone:(816) 260-6092  
UPTOWN EATERY, Address:209 SE GREEN ST, Phone:(816) 260-6092  
Reviews
Review Type Outcome Est. Completion Date Completed
Fire Plan Review Approved with Conditions 04/26/2013 04/19/2013
Tracy Deister
Type I hood - Where required
Corrective Action Required
04/19/2013

2006 IFC 609.2- Where required. A Type I hood shall be installed at or above all commercial cooking appliances and domestic cooking appliances used for commercial purposes that produce grease vapors. Provide specs on hood system, if grease laden vapors will not be produced provide a letter stating this is to be a warming kitchen only.
Portable fire extinguishers - general
Corrective Action Required
04/19/2013

2006 IFC 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Pvovide a minimum of one 2A10B:C fire extinguisher, verified at inspection
Misc
Corrective Action Required
04/19/2013

1004.3 Posting of occupant load. Every room or space that is an assembly occupancy shall have the occupant load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or authorized agent. Post a maximum occupancy sign near the entrance, verified at inspection
Building Plan Review Approved with Conditions 04/26/2013 04/19/2013
Tracy Deister
Internal Plan Review (Res) Rejected 12/03/2012
Tracy Deister
Corrective Action Required
12/03/2012

Building Plan Review Rejected 12/12/2012 12/03/2012
Tracy Deister
Corrective Action Required
12/03/2012

All plumbing, mechanical and electrical work must be performed by a licensed contractor. Before a permit can be issued all contractors you have listed on your application must have a current business license in the City of Lee's Summit.
Corrective Action Required
12/03/2012

Verify what type of materials will be used to construct the new non-load bearing partitions. Make note on drawing stating what materials will be used.
Corrective Action Required
12/03/2012

IPC Section 802.1.1 Food handling. Equipment and fixtures utilized for the storage, preparation and handling of food shall discharge through an indirect waste pipe by means of an air gap. Make note on drawing stating this requirement will be met.
Corrective Action Required
12/03/2012

What type of hood will be installed a type I or type II? Is the hood used? More information needs to be submitted before comments can be made. Submit additional information on the proposed hood over the stove/grill.
Fire Plan Review Rejected 12/12/2012 12/03/2012
Brian Austerman
Type I hood - Where required
Corrective Action Required
12/03/2012

2006 IFC 609.2- Where required. A Type I hood shall be installed at or above all commercial cooking appliances and domestic cooking appliances used for commercial purposes that produce grease vapors. Provide specs on hood system, if grease laden vapors will not be produced provide a letter stating this is to be a warming kitchen only.
Portable fire extinguishers - general
Corrective Action Required
12/03/2012

2006 IFC 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Pvovide a minimum of one 2A10B:C fire extinguisher, verified at inspection
Misc
Corrective Action Required
12/03/2012

1004.3 Posting of occupant load. Every room or space that is an assembly occupancy shall have the occupant load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or authorized agent. Post a maximum occupancy sign near the entrance, verified at inspection
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for Alteration to Commercial $30.00 $30.00 Paid 05/24/2013
8331507-Sewer Connection Fee $90.00 $90.00 Paid 05/24/2013
$90.00
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Rough Plumbing Inspection - Commercial Passed 6/25/2013 at 12:00 AM 06/25/2013
Occupancy Inspection - Codes Commercial Failed 8/19/2013 8/19/2013 at 12:00 AM 08/19/2013
Misc
Corrective Action Required
08/19/2013
RESOLVE ANY WATER UTILITIES ISSUES
Misc
Corrective Action Required
08/19/2013
RESOLVE ANY FIRE DEPARTMENT ISSUES
Misc
Corrective Action Required
08/19/2013
RESOLVE ANY PLANNING AND DEVELOPMENT ISSUES
Misc
Corrective Action Required
08/19/2013
ISSUES WITH ELECTRICAL RECEPTACLES: A) SOME RECEPTACLES NOT SOLID TO BOX B) SOME RECEPTACE DISPLAY OPEN GROUND C) SOME RECEPTACLES DISPLAY HOT/NEUTRAL REVERSE D) ENSURE ALL RECEPTS HAVE COVER PLATES *******CHECK ALL*******
Misc
Corrective Action Required
08/19/2013
NEC 408.4: LABELING OF ELECTRICAL CIRCUIT POSITIONS AT PANEL(S): EACH BREAKER POSITION MUST BE LABELED. MUST BE LEGIBLE, SPECIFIC. IF PANEL SCHEDULE IS USED NUMBER POSITIONS ON PANEL FRONT PER SCHEDULE. NO DITTO MARKS OR CONTINUATION SYMBOLS EXCEPT @ MULTIPLE POLE BREAKERS. LABEL UNUSED BREAKERS "SPARE"
Misc
Corrective Action Required
08/19/2013
COFFEE MAKER IF TO BE WATER-FED MUST HAVE APPROVED LOCAL BACKFLOW PROTECTION.
Misc
Corrective Action Required
08/19/2013
SAFETY INSPECTION AT ROOF SUBJECT TO APPROVAL.
Occupancy Inspection - Fire Temporary C of O 8/19/2013 at 12:00 AM 08/19/2013
Misc
Corrective Action Required
08/19/2013
- mount the fire extinguisher in the kitchen area close to the exit with the top of the extinguisher no higher than 60' off of the floor - occupant needs to supply a letter stating that the stove will not be generating grease laden vapors, that it will be used for warming purposes only - install a cover plate on the electrical outlet in the kitchen located by the coolers
Occupancy Inspection - Codes Commercial Temporary C of O 9/4/2013 9/4/2013 at 12:00 AM 09/04/2013
Misc
Corrective Action Required
08/19/2013
RESOLVE WATER UTILITIES ISSUE ON TIMETABLE AGREED-UPON WITH LSWU
Misc
Resolved
09/04/2013
RESOLVE ANY FIRE DEPARTMENT ISSUES
Misc
Resolved
09/04/2013
RESOLVE ANY PLANNING AND DEVELOPMENT ISSUES
Misc
Corrective Action Required
08/19/2013
ISSUES WITH ELECTRICAL RECEPTACLES: - RECEPTACLE @ S PANEL NOT SOLID TO WALL - RECEPTACLE @ SERVING COUNTER SOUTH END DISPLAYS HOT/NEUTRAL REVERSE
Misc
Resolved
09/04/2013
NEC 408.4: LABELING OF ELECTRICAL CIRCUIT POSITIONS AT PANEL(S): EACH BREAKER POSITION MUST BE LABELED. MUST BE LEGIBLE, SPECIFIC. IF PANEL SCHEDULE IS USED NUMBER POSITIONS ON PANEL FRONT PER SCHEDULE. NO DITTO MARKS OR CONTINUATION SYMBOLS EXCEPT @ MULTIPLE POLE BREAKERS. LABEL UNUSED BREAKERS "SPARE"
Misc
Resolved
09/04/2013
COFFEE MAKER IF TO BE WATER-FED MUST HAVE APPROVED LOCAL BACKFLOW PROTECTION.
Misc
Corrective Action Required
08/19/2013
SAFETY INSPECTION AT ROOF SUBJECT TO APPROVAL.
Misc
Corrective Action Required
09/04/2013
COMPLETE SUPPORT OF PVC ELECT CONDUIT AT S EAVE OF BLDG
Misc
Corrective Action Required
09/04/2013
NEC 330.30: NON-METALLIC ELECTRICAL WHIP NOT SECURED TO STRUCTURE WITHIN 12" OF ENTRY TO A/C DISCONNECT ENCLOSURE.
Occupancy Inspection - Fire Passed 9/4/2013 at 12:00 AM 09/04/2013
Misc
Corrective Action Required
08/19/2013
- mount the fire extinguisher in the kitchen area close to the exit with the top of the extinguisher no higher than 60' off of the floor - occupant needs to supply a letter stating that the stove will not be generating grease laden vapors, that it will be used for warming purposes only - install a cover plate on the electrical outlet in the kitchen located by the coolers
Occupancy Inspection - Codes Commercial Full C of O 9/12/2013 9/12/2013 at 12:00 AM 09/12/2013
Misc
Resolved
09/12/2013
RESOLVE WATER UTILITIES ISSUE ON TIMETABLE AGREED-UPON WITH LSWU
Misc
Resolved
09/12/2013
ISSUES WITH ELECTRICAL RECEPTACLES: - RECEPTACLE @ S PANEL NOT SOLID TO WALL - RECEPTACLE @ SERVING COUNTER SOUTH END DISPLAYS HOT/NEUTRAL REVERSE
Misc
Resolved
09/12/2013
SAFETY INSPECTION AT ROOF SUBJECT TO APPROVAL.
Misc
Resolved
09/12/2013
COMPLETE SUPPORT OF PVC ELECT CONDUIT AT S EAVE OF BLDG
Misc
Resolved
09/12/2013
NEC 330.30: NON-METALLIC ELECTRICAL WHIP NOT SECURED TO STRUCTURE WITHIN 12" OF ENTRY TO A/C DISCONNECT ENCLOSURE.
Documents & Images
Date Uploaded File Type Document Name
12/03/2012 Letter Plan Review Conditions
05/24/2013 Letter Building Permit
06/21/2013 Letter Fire Building Plan Review
06/21/2013 Letter Fire Building Plan Review
06/25/2013 Letter Inspection Summary
06/25/2013 Letter Fire Building Plan Review
08/19/2013 Letter Inspection Summary
08/19/2013 Letter Fire Loss Reduction Form
09/04/2013 Letter Codes Temporary Certificate of Occupancy
09/12/2013 Letter Field Certificate of Occupancy
09/13/2013 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home