Review Type |
Outcome |
Est. Completion Date |
Completed |
Building Codes Review
|
No Comments
|
04/20/2022
|
04/20/2022
|
|
Joe Frogge
|
|
Miscellaneous Correction
Show accessible route from parking to building entry.
3/24/22 - not addressed. accessible parking looks hemmed in by curbs. are there stairs/ramp into building?
|
|
|
Fire Review
|
No Comments
|
04/20/2022
|
04/20/2022
|
|
Jim Eden
|
|
|
Engineering Review
|
Approved with Conditions
|
04/20/2022
|
04/15/2022
|
|
Loic Nguinguiri, E.I.
|
|
DE Future Repair Work
Corrective Action Required
Please be aware that any future repair work to public infrastructure (e.g., water main repair, sanitary sewer repair, storm sewer repair, etc.) within public easements will not necessarily include the repair of pavement, curbing, landscaping, or other private improvements which are located within the easement.
|
|
DE C&O #11 Pavement Thickness
Corrective Action Required
Private parking lots shall follow Article 8 of the Unified Development Ordinance for pavement thickness and base requirements.
|
|
DE Contact Field Eng. Inspector
Corrective Action Required
Prior to the commencement of any construction activities, the Contractor shall contact Field Engineering Inspections at (816) 969-1200 to coordinate a preconstruction meeting / conference with the assigned Field Engineering Inspector.
|
|
DE Engineers Estimate
Corrective Action Required
The Engineer’s Estimate of Probable Construction Costs has been accepted for this project, and the Engineering Plan Review and Inspection Fee (which is calculated as 3% of the total infrastructure cost plus a water test inspection fee(s)), and the water tap and meter setup fee have been included. These must be paid prior to the issuance of an infrastructure permit and/or the final processing of a building permit. $286.93
|
|
|
Traffic Review
|
No Comments
|
04/20/2022
|
04/14/2022
|
|
Brad Cooley, P.E., RSPI
|
|
|
Planning Review
|
No Comments
|
04/20/2022
|
04/14/2022
|
|
Shannon McGuire
|
|
|
Engineering Review
|
Corrections
|
03/31/2022
|
03/31/2022
|
|
Loic Nguinguiri, E.I.
|
|
Corrective Action Required
Sheet numbers shown, such as C.100 and C.101, don’t match with the index of sheets. Please revise.
|
|
Corrective Action Required
A construction detail of the proposed retaining wall needs to be included in the set of plans. A design also has to be provided if the wall is higher than 4 feet tall.
|
|
Corrective Action Required
Edges of proposed retaining walls must be at least 15 feet away from the existing 6” public water main.
|
|
Corrective Action Required
Show proposed finish spot elevations, such as bottom/top of curb and finish grade elevations, over the new asphalt parking and curb area. Include arrows showing the direction of (runoff) flow, as well.
|
|
Corrective Action Required
On sheet C.101, revise the concrete flume leader. A (shallow) curb cut at this location may be sufficient.
|
|
Corrective Action Required
Provide the clarification for, or remove the bubbled “added 4” aggregate” shown on sheet C.600.
|
|
|
Traffic Review
|
No Comments
|
03/31/2022
|
03/30/2022
|
|
Brad Cooley, P.E., RSPI
|
|
|
Fire Review
|
No Comments
|
03/31/2022
|
03/30/2022
|
|
Jim Eden
|
|
|
Planning Review
|
No Comments
|
03/31/2022
|
03/27/2022
|
|
Shannon McGuire
|
|
|
Building Codes Review
|
Corrections
|
03/31/2022
|
03/24/2022
|
|
Joe Frogge
|
|
Miscellaneous Correction
Corrective Action Required
Show accessible route from parking to building entry.
3/24/22 - not addressed. accessible parking looks hemmed in by curbs. are there stairs/ramp into building?
|
|
|
Planning Review
|
Corrections
|
02/22/2022
|
02/23/2022
|
|
Shannon McGuire
|
|
Corrective Action Required
The approved PDP landscaping plan required parking lot screening of 12 shrubs per 40 linear feet to a height of two and one-half (2.5’) feet, be provided along the edge of the parking lot area parallel to the western property line. Please update the plans to meet this requirement.
|
|
Corrective Action Required
All signs must comply with the sign requirements as outlined in the sign section of the ordinance.
|
|
Corrective Action Required
Please provide a brief narrative of the proposed work to be complete on the exterior of the existing building.
|
|
|
Traffic Review
|
No Comments
|
02/22/2022
|
02/17/2022
|
|
Susan Barry, P.E.
|
|
|
Engineering Review
|
Corrections
|
02/22/2022
|
02/15/2022
|
|
Loic Nguinguiri, E.I.
|
|
Corrective Action Required
Mention “Renourish”, with(in) the title on the cover sheet.
|
|
Corrective Action Required
Title block information (i.e. sheet title & sheet number), shown throughout the set of plans, must match the information shown in the index of sheets located on the cover sheet.
|
|
Corrective Action Required
Revise the bar scale(s), shown throughout the set of plans, as necessary. (i.e. 1” = 10’ appears to be the accurate one)
|
|
Corrective Action Required
Show proposed temporary construction entrance on sheet C.051 or revise the language. The language shown on sheet C.051 should discuss the ESC measures to be used only, as part of this scope of work.
|
|
Corrective Action Required
Include construction details for the two (2) proposed retaining walls.
|
|
Corrective Action Required
Show proposed finish spot elevations over the new parking and curb area.
|
|
Corrective Action Required
Specify the type(s) of curb and gutter to be used, on the site plan sheet. A curb cut (or a concrete flume) would also be needed between the rip-rap and the new asphalt pavement.
|
|
Corrective Action Required
Should not an ADA ramp be installed for this development?
|
|
Corrective Action Required
Show the proposed direction for the 1” PVC discharge pipe draining to daylight. Stormwater runoff from discharge pipe needs to drain towards the northwest corner of the lot.
|
|
Corrective Action Required
Include the GEN-1, GEN-2 and GEN-4 standard details. ESC details are accessible through the Design & Construction manual tab located on the City’s website.
|
|
Corrective Action Required
Please provide a stormwater management memorandum.
|
|
Corrective Action Required
Please provide an Engineer’s Opinion of Probable Construction Cost (EOOPCC) sheet
|
|
|
Building Codes Review
|
Corrections
|
02/22/2022
|
02/10/2022
|
|
Joe Frogge
|
|
Miscellaneous Correction
Corrective Action Required
Show accessible route from parking to building entry.
|
|
|
Fire Review
|
No Comments
|
02/22/2022
|
02/07/2022
|
|
Jim Eden
|
|
|