Planning Application Status

PL2025118




 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PL2025118
Telecommunications Monopole SUP – Joint Operations Facility
Special Use Permit
Special Use Permit
In Plan Review
05/21/2025
CITY OF LEES SUMMIT
160 foot monopole tower between the Joint Operations Facility and Police/Court building.
Locations
Contacts
CITY OF LEES SUMMIT, Address:207 SW MARKET ST  
Sharon Bloom  
Dean Hart - Tusa Consulting   
Lovelace & Associates LLC, Address:929 SE 3rd St, Phone:(816) 347-9997  
Reviews
Review Type Outcome Est. Completion Date Completed
Planning Review Corrections 06/06/2025 06/06/2025
Hector Soto Jr.
Corrective Action Required
06/06/2025

SETBACKS. The UDO requires new towers to maintain a minimum setback from all property lines a distance equal to the height of the tower as measured from the base of the structure to its highest point. The proposed monopole is 150' plus an additional 10' for a lightning rod, for a total height of 160'. The proposed tower location satisfies the minimum setback requirement from the north, east and west property lines, but does not meet the minimum setback from the south property line that is located approximately 60' away. Approval of a modification request to the minimum setback requirement shall be required of the City Council as part of this application. Please provide additional detail about what other locations within the boundaries of the existing Police and Courts/future JOF property were considered that would satisfy the minimum setback requirements and why those locations were not chosen. For example, the existing tower location on the south side of the Police/Courts building is located approximately 180' from the south property line, which would meet the 160' setback requirement. Why could the existing tower site or similar site more interior to the property not accommodate the proposed tower? Could existing parking spaces behind the Police/Courts building not be removed and relocated to create a site for the tower? We need more background information regarding what considerations were made for alternate sites within the property boundaries leading to the selection of the proposed tower site along the NE Tudor Rd frontage as the optimal choice for inclusion in the staff report and in preparation for the public hearings before the Planning Commission and City Council.
Corrective Action Required
06/06/2025

SEPARATION DISTANCES. The UDO requires new towers over 90' in height to be separated from any other telecommunications tower over 90' in height by a distance of at least one (1) mile. The proposed tower location is separated from a 200'-tall tower located at 1351 NW Ward Rd by a distance of approximately 0.93 miles (~4,926') and thus does not meet the minimum separation requirement. Approval of a modification request to the minimum separation requirement shall be required of the City Council as part of this application. This comment is for informational and documentation purposes. No further response is required.
Corrective Action Required
06/06/2025

LANDSCAPING. The UDO requires that a telecommunication tower be landscaped to provide a buffer of plant materials that effectively screens the view of the tower base and accessory structures from adjacent property. The landscape plan shows a single row of evergreens consisting of a total of 7 trees along the southwest and southeast perimeter of the tower enclosure. Given the fact that the tower is located approximately 60' from the south property line; the fence enclosure being located approximately 20' from the south property line; and the tower facility being located along an arterial road, staff recommends that a double staggered row of evergreen trees be provided along the southwest and southeast perimeter of the tower enclosure to provide an immediate opaque living screen of the tower base and accessory structure.
Corrective Action Required
06/06/2025

SECURITY FENCING. The UDO requires that a telecommunication tower be enclosed by fencing not less than 6' in height and equipped with an appropriate anti-climbing device. Provide a detail of the proposed fencing with anti-climbing device for review.
Corrective Action Required
06/06/2025

TOWER DESIGN. The UDO requires that a telecommunication tower be painted a neutral color approved by the City Council so as to reduce visual obtrusiveness. Provide a tower detail/elevation that calls out the proposed tower finish and color. The tower rendering shows the tower as white, but no information is provided indicating if that is the proposed tower's actual color or what type of finish it will have. For your information, some past telecommunication tower applications have proposed towers with just an unpainted galvanized finish, rather than a painted finished, to avoid the need for on-going maintenance of chipped or peeling paint on the tower exterior. City Council has approved towers with unpainted galvanized finishes in the past.
Corrective Action Required
06/06/2025

SITE PLAN. The architectural site plan does not show property lines. Add and identify the property lines on the site plan.
Engineering Review No Comments 06/06/2025 05/29/2025
Gene Williams, P.E.
Traffic Review No Comments 06/06/2025 05/27/2025
Erin Ralovo
Fire Review No Comments 06/06/2025 05/27/2025
Jim Eden
Fees
Paid Fees Amount Paid Owing Date Paid
9110077-Special Use Permit fee $1,075.00 $1,075.00 Paid 06/10/2025
9110076-Legal Notice Publishing Charge $165.00 $165.00 Paid 06/10/2025
9110076-Legal Notice Publishing Charge $165.00 $165.00 Paid 06/10/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Hearings
Title Location Date Time
Planning Commission Meeting 07/24/2025 5:00 PM Council Chambers 07/24/2025 05:00 PM
Agenda Item
Pending
07/24/2025
City Council Public Hearing 09/02/2025 6:00 PM Council Chambers 09/02/2025 06:00 PM
Agenda Item
Pending
09/02/2025
City Council Ordinance 2nd Reading 09/09/2025 6:00 PM Council Chambers 09/09/2025 06:00 PM
Agenda Item
Pending
Documents & Images
Date Uploaded File Type Document Name
05/21/2025 Plans Landscape Plan_Rev 0_PL2025118
05/21/2025 Plans Renderings_PL2025118
05/21/2025 Plans Site Plan_Rev 0_PL2025118
05/21/2025 Application Form Application Form with narrative_PL2025118
05/21/2025 Application Form Application Form_PL2025118
05/29/2025 Public Notice Document Notification list_PL2025118
06/06/2025 Letter Applicant Letter_Rev 0_PL2025118
06/09/2025 Public Notice Document Notice to property owners_NH_PC_CC_PL2025118
06/10/2025 Receipt Receipt for transaction: 2025-004352
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New license, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home