Planning Application Status

PL2022371




 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PL2022371
Fire Station #4 - Public Sanitary Sewer
Engineering Plan Review
Engineering Plan Review
Approved
10/21/2022
CITY OF LEES SUMMIT
Extend the public sanitary beyond the new plat boundary.
Locations
Contacts
CITY OF LEES SUMMIT, Address:220 SE GREEN ST  
GLMV ARCHITECTURE , Address:9229 WARD PKWY SUITE #210, Phone:(816) 444-4200  
Reviews
Review Type Outcome Est. Completion Date Completed
Record Drawings Review No Comments 11/27/2024 11/27/2024
Mike Weisenborn
Record Drawings Review Corrections 07/23/2024 07/24/2024
Sue Pyles, P.E.
Corrective Action Required
07/24/2024

See email.
Engineering Review No Comments 12/19/2022 12/16/2022
Gene Williams, P.E.
Engineering Review Corrections 12/05/2022 12/02/2022
Gene Williams, P.E.
Corrective Action Required
12/02/2022

A cover sheet is required. Please use the title "Lee's Summit Fire Station #4 - Public Sanitary Sewer Modifications" or equivalent language.
Corrective Action Required
12/02/2022

The short extension is nearly flat, and does not meet our dead-end sanitary sewer slope requirement of 1.00%. Please adjust to 1.00% or greater if possible.
Corrective Action Required
12/02/2022

A trenching and backfill detail was missing. Please provide a trenching and backfill detail, and ensure it includes the July 2020 revision of 12 inch minimum aggregate over the top of pipe. Please be aware the City does not have a standard drawing for a trenching and backfill detail, so it will need to be prepared by your firm.
Engineering Review Corrections 11/03/2022 11/03/2022
Gene Williams, P.E.
Hearings

There are no hearings for this planning application.

Documents & Images
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New license, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide: