Planning Application Status

PL2022169




 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PL2022169
Lumberman's Row - Public Water
Engineering Plan Review
Engineering Plan Review
Approved
04/29/2022
Locations
Address
1205 SW CORINTHIAN LN, LEES SUMMIT, MO 64081

Address
1209 SW CORINTHIAN LN, LEES SUMMIT, MO 64081

Address
1213 SW CORINTHIAN LN, LEES SUMMIT, MO 64081

Address
1221 SW CORINTHIAN LN, LEES SUMMIT, MO 64081

Address
1225 SW CORINTHIAN LN, LEES SUMMIT, MO 64081

Address
1229 SW CORINTHIAN LN, LEES SUMMIT, MO 64081

Address
1241 SW CORINTHIAN LN, LEES SUMMIT, MO 64081

Address
1240 SW CORINTHIAN LN, LEES SUMMIT, MO 64081

Address
1232 SW CORINTHIAN LN, LEES SUMMIT, MO 64081

Address
1228 SW CORINTHIAN LN, LEES SUMMIT, MO 64081

Address
1224 SW CORINTHIAN LN, LEES SUMMIT, MO 64081

Address
1220 SW CORINTHIAN LN, LEES SUMMIT, MO 64081

Address
1216 SW CORINTHIAN LN, LEES SUMMIT, MO 64081

Address
1212 SW CORINTHIAN LN, LEES SUMMIT, MO 64081

Address
1208 SW CORINTHIAN LN, LEES SUMMIT, MO 64081

Address
1204 SW CORINTHIAN LN, LEES SUMMIT, MO 64081

Address
1200 SW CORINTHIAN LN, LEES SUMMIT, MO 64081

Address
1237 SW CORINTHIAN LN, LEES SUMMIT, MO 64081

Address
1245 SW CORINTHIAN LN, LEES SUMMIT, MO 64081

Address
1236 SW CORINTHIAN LN, LEES SUMMIT, MO 64081

Property
62430997700000000

Property
62430997800000000

Property
62430997500000000

Property
62430997400000000

Property
62430997300000000

Property
62430997200000000

Property
62430997100000000

Property
62430997000000000

Property
62430996900000000

Property
62430998000000000

Property
62430998100000000

Property
62430998200000000

Property
62430998300000000

Property
62430998400000000

Property
62430998500000000

Property
62430998600000000

Property
62430998700000000

Property
62430998800000000

Property
62430997600000000

Property
63600041600000000

Address
1201 SW CORINTHIAN LN, LEES SUMMIT, MO 64081

Contacts
RUSSELL PEARSON, Address:3152 GRANDSTAND CIR, Phone:(913) 735-9861  
DAVID RINNE, Address:SCHLAGEL ASSOCIATES  
Scott Ready, Phone: 8169691225  
Reviews
Review Type Outcome Est. Completion Date Completed
Record Drawings Review No Comments 06/03/2023 06/01/2023
Sue Pyles, P.E.
Engineering Review No Comments 11/29/2022 11/21/2022
Sue Pyles, P.E.
Engineering Review Corrections 11/04/2022 11/03/2022
Sue Pyles, P.E.
Corrective Action Required
11/03/2022

Please revise the FH layout: • Relocate the FH shown at the Lot 9 – Tract B lot line to the Lot 7 – Tract A lot line. • Add a FH at the Lot 2 – Lot 3 lot line.
Corrective Action Required
11/03/2022

With the removal of the FH at the end of the main, a blowoff assembly will be required. The City no longer uses the current standard detail. I’ve attached the new detail. If you would like to have the detail in AutoCAD format, please let me know.
Corrective Action Required
11/03/2022

Please update the estimate accordingly.
Engineering Review Corrections 08/31/2022 08/31/2022
Sue Pyles, P.E.
Corrective Action Required
08/31/2022

Please revise Line 2 to go from the bend at Sta. 10+16.81 directly to the FH. The FH should be called out as a “straight” or “in-line” hydrant.
Corrective Action Required
08/31/2022

Label the gate valve on Line 4 near Line 2 in Plan view.
Corrective Action Required
08/31/2022

How will having a restrained pipe on the south side of the 90 degree bend and an unrestrained pipe east of the bend effect the main?
Corrective Action Required
08/31/2022

I have asked for a fire review of the proposed FH locations. That will not be available until next week, so I’ll forward under separate cover.
Hearings

There are no hearings for this planning application.

Documents & Images
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New license, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home