Permit Application Status

PRSUBD20235226


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary


PRSUBD20235226
Public Infrastructure
Withdrawn
TOWNSEND SUMMIT LLC
DEVELOPMENT COMPLETE
PUBLIC SANITARY SEWER EXTENSION TO SERVE 1010 NW WARD RD WOODSPRING SUITES
10/10/2023
06/23/2025
06/23/2025
Locations
Contacts
TOM WOOTEN, Address:OWN, INC, Phone:(573) 489-2092  
Marcus Gutierrez - Genesis Construction, Phone:(716) 492-8291  
TOWNSEND SUMMIT LLC, Address:230 SCHILLNG CIR STE 120  
OWN INC, Address:4240 PHILIPS FARM RD, SUITE 101  
Genesis Construction Management CO, Address:4420 Madison Ave. Suite 100  
Reviews
Review Type Outcome Est. Completion Date Completed
Engineering Review - Sanitary Approved with Conditions 01/04/2024 12/18/2023
Susan Nelson, P.E.
Miscellaneous Correction
Corrective Action Required
12/18/2023

Contact Development Services Inspections at (816) 969-1200 to schedule a pre-construction meeting.
Miscellaneous Correction
Corrective Action Required
12/18/2023

Please submit two (2) paper copies (one full size and one 11”x17”) with the red Bluebeam authentication stamp to Ryan Heckman, City Hall, 220 SE Green St., Lee’s Summit, MO 64063. No work described by the plans shall be allowed until these plans have been submitted to the City, and a pre-construction meeting has been held between Ryan Heckman and the contractor.
Miscellaneous Correction
Corrective Action Required
12/18/2023

Any public improvements will require a set of Record Drawings prior to acceptance.
Miscellaneous Correction
Corrective Action Required
12/18/2023

All permanent off-site easements, in a form acceptable to the City, shall be executed and recorded with the Jackson County Recorder of Deeds prior to issuance of a Certificate of Substantial Completion. A certified copy shall be submitted to the City for verification.
Miscellaneous Correction
Corrective Action Required
12/18/2023

Note that any improvements installed over City utilities or within City easements will not be repaired or replaced if future utility maintenance is required, including, but not limited to, pavement, curbing and guttering, landscaping, trees, shrubs, or other items.
Engineering Review - Sanitary Corrections 12/08/2023 12/01/2023
Susan Nelson, P.E.
Miscellaneous Correction
Corrective Action Required
11/22/2023

In the pipe profiles where compacted fill is required, please also show the hatching below the pipe. For reference, an example of how this could be shown will be sent by separate document. Add to the notes the following for clarity. Contractor shall fill and compact to 95% standard density to a point 18 inches minimum above the top of the pipe prior to excavation for the pipe.
Miscellaneous Correction
Corrective Action Required
11/22/2023

For informational purpose only. The additional easement for the public sanitary shall be dedicated prior to issuance of the substantial completion for the public sanitary and any type of occupancy for the private development.
Engineering Review - Sanitary Corrections 10/24/2023 10/27/2023
Susan Nelson, P.E.
Miscellaneous Correction
Corrective Action Required
10/27/2023

Please add the Manhole Wall Connections detail to the plans.
Miscellaneous Correction
Corrective Action Required
10/27/2023

Show the proposed easement for the public sanitarty as S/E instead of U/E.
Miscellaneous Correction
Corrective Action Required
10/27/2023

Please note: The additional easement for the public sanitary shall be dedicated prior to issuance of the substantial completion for the public sanitary and any type of occupancy for the private development.
Engineering is still coordinating with Water Utilities.
Inspections

There are no inspections for this permit application.

Documents & Images
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home