Permit Application Status

PRRESRES20204862


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRESRES20204862
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - COVERED DECK
12/21/2020
01/04/2021
06/21/2021
02/04/2022
Locations
Contacts
TRUMARK HOMES, LLC, Address:PO BOX 728, Phone:(816) 564-5613  
C.M. MOSE & SON, Address:6603 ROYAL ST BLDG E, Phone:(816) 781-4707  
IMPACT ELECTRICAL SOLUTIONS LLC, Address:14 ANCHOR DRIVE, Phone:(816) 674-9345  
A BRIGHT PLUMBING LLC, Address:18107 E 18TH TER N, Phone:(816) 215-0730  
TRUMARKHOMES.MARK@GMAIL.COM  
  
  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 12/29/2020 12/23/2020
Brandon Kalwei
Residential Plan Review Approved 12/29/2020 12/23/2020
Brandon Kalwei
12 Detail required separation between garage and living area including door
Corrective Action Required
12/23/2020

Detail required separation between garage and living area including door, door closer and gypsum board. (IRC R302.5) Cannot locate gypsum board details.
Plot Plan Review Approved 12/28/2020 12/22/2020
Brandon Kalwei
Residential Plan Review Rejected 12/28/2020 12/22/2020
Brandon Kalwei
12 Detail required separation between garage and living area including door
Corrective Action Required
12/22/2020

Detail required separation between garage and living area including door, door closer and gypsum board. (IRC R302.5) Cannot locate gypsum board details.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,058.72 $1,058.72 Paid 01/04/2021
8331507-Sewer Connection Fee $540.00 $540.00 Paid 01/04/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 01/04/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 01/04/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 01/04/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 01/04/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 2/2/2021 (10:45) 2/2/2021 02/02/2021
Misc
Informational
02/02/2021
- POST ADDRESS - - UFER FOUNDATION WALL NEAR STAIRWAY -
Underslab Plumbing Inspection - Residential Failed 3/5/2021 03/05/2021
Misc
Corrective Action Required
03/05/2021
- CONNECT UNDERSLAB INTERIOR DRAIN TILE TO SUMP -
Underslab Plumbing Inspection - Residential Passed 3/19/2021 3/19/2021 03/19/2021
Misc
Resolved
03/19/2021
Sewer Service Inspection - R Passed 3/29/2021 (8:30) 3/29/2021 03/29/2021
Water Service Inspection - R Passed 3/30/2021 03/30/2021
Miscellaneous Inspection Partial 4/6/2021 4/6/2021 04/06/2021
Misc
Informational
04/06/2021
- GARAGE PFH PORTAL FRAMING ONLY - - NAILING PATTERN HEADER & HOLDDOWNS EXTERIOR OK TO COVER -
Erosion Control Inspection Residential Failed 5/14/2021 05/14/2021
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
05/14/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE -
Electrical Service Inspection Passed 5/14/2021 5/14/2021 05/14/2021
All Rough Inspection - Residential Failed 5/14/2021 5/14/2021 05/14/2021
Miscellaneous Correction
Corrective Action Required
05/14/2021
POST ADDRESS Tighten anchor bolts garage Seal upward penetration overhead doors Provide joist hangers garage landing Seal upward penetration top plate stairway & above doorbell box Nail joist hanger rafter above entry stairs Seal fire block top furr out basement Secure box oven/microwave Provide roof boots Throughout Address rafter to ceiling joist connection master bath & closet Seal fire block top plate dbl wall dining room / master Complete gas lines, hook up fireplace Fire block fireplace at ridge Provide joist hanger 2 x 10 above stairs to basement Tighten anchor bolts basement ( anchor bolts shall be in middle 1/3 the width of plate ) Vertical fire block basement furr out every 10' min Column pad no SCH 40 column under dbl 2 x 10 near service panel Seal upward penetration near service panel Install missing egress windows Fireblock beam at stud pack basement bed near garage Seal fire block columns in bed #3 closet Seal DWV & upward penetration near tub jack n Jill bath Fireblock closet bed #2 Nail sheathing per plan 6" edge 12" field Fire block chase outside basement bath
Gas Service Inspection - Residential Passed 5/18/2021 05/18/2021
All Rough Inspection - Residential Failed 5/18/2021 05/18/2021
Miscellaneous Correction
Corrective Action Required
05/17/2021
***OK TO INSULATE Install missing egress windows ( BACKORDERED)
All Rough Inspection - Commercial Failed 5/19/2021 5/19/2021 05/19/2021
Miscellaneous Correction
Corrective Action Required
05/19/2021
INSTALL BACKORDERED EGGRESS WINDOWS BASEMENT OK TO INSULATE
Piers/Caissons Inspection - Residential Passed 6/18/2021 6/18/2021 06/18/2021
Driveway Inspection Partial 7/6/2021 7/6/2021 07/06/2021
Misc
Informational
07/06/2021
7-6-21 1:07pm The forms are set and the aggregate is compacted. The contractor knows to stay ADA compliant through the driveway. The driveway is 30’ wide.
Sidewalk Inspection Partial 7/6/2021 7/6/2021 07/06/2021
Misc
Informational
07/06/2021
7-6-21 1:09pm Full sun 87 degrees. The forms are set and are ADA compliant at this time. I informed the contractor to use a broom finish and white cure.
Driveway Inspection Passed 7/9/2021 7/9/2021 07/09/2021
Misc
Informational
07/06/2021
7-6-21 1:07pm The forms are set and the aggregate is compacted. The contractor knows to stay ADA compliant through the driveway. The driveway is 30’ wide.
Misc
Informational
07/09/2021
Finished driveway meets LS and ADA specs. RP 7-9-21
Sidewalk Inspection Passed 7/9/2021 7/9/2021 07/09/2021
Misc
Informational
07/06/2021
7-6-21 1:09pm Full sun 87 degrees. The forms are set and are ADA compliant at this time. I informed the contractor to use a broom finish and white cure.
Misc
Informational
07/09/2021
Finished sidewalk meets LS and ADA specs. RP 7-9-21
Plot Plan Inspection Passed 01/25/2022
Miscellaneous Inspection Passed 01/25/2022
Misc
Informational
04/06/2021
- GARAGE PFH PORTAL FRAMING ONLY - - NAILING PATTERN HEADER & HOLDDOWNS EXTERIOR OK TO COVER -
Piers/Caissons Inspection - Residential Passed 01/25/2022
Occupancy Inspection - Codes Residential Failed 1/25/2022 01/25/2022
Misc
Resolved
01/25/2022
- HAMMER ARRESTORS IN WALL AT LAUNDRY -
Miscellaneous Correction
Corrective Action Required
01/25/2022
- Label non GFCI outlet in garage - Provide spark rings outlets kitchen counter - Gfci outlet over bar counter will not reset - Outlets at bar need spark rings - Label non GFCI outlets in basement - Smoke detector by furnace covered and beeping - Provide 6” clearance grade to siding garage by front door sidewalk - Provide 2 x 1/2'" through bolts on all post to beam connections - complete irrigation permit and submit backflow cert.
Deck Final Inspection - Residential Passed 02/04/2022
Occupancy Inspection - Codes Residential Full C of O 2/4/2022 2/4/2022 02/04/2022
Miscellaneous Correction
Resolved
02/04/2022
submit backflow cert.
Documents & Images
Date Uploaded File Type Document Name
12/21/2020 Approved Plans APPLICATION
12/22/2020 Plot Plan APPROVED PLOT PLAN
12/22/2020 Letter Codes Residential Plan Review
12/23/2020 Approved Plans APPROVED PLANS
01/04/2021 Receipt Receipt for transaction:2021-000024
01/04/2021 Letter DS Building Permit
01/04/2021 83 woodside signed conditions sheet
02/02/2021 Letter INSPECTION SUMMARY
03/05/2021 Letter INSPECTION SUMMARY
03/19/2021 Letter INSPECTION SUMMARY
03/29/2021 Letter INSPECTION SUMMARY
03/30/2021 Letter INSPECTION SUMMARY
04/06/2021 Letter INSPECTION SUMMARY
06/18/2021 Letter INSPECTION SUMMARY
06/18/2021 Letter INSPECTION SUMMARY
06/18/2021 Letter INSPECTION SUMMARY
07/06/2021 Letter INSPECTION SUMMARY
07/06/2021 Letter INSPECTION SUMMARY
07/06/2021 Letter INSPECTION SUMMARY
07/06/2021 Letter INSPECTION SUMMARY
07/06/2021 Letter INSPECTION SUMMARY
07/09/2021 Letter INSPECTION SUMMARY
07/09/2021 Letter INSPECTION SUMMARY
07/09/2021 Letter INSPECTION SUMMARY
07/09/2021 Letter INSPECTION SUMMARY
07/09/2021 Letter INSPECTION SUMMARY
07/09/2021 Letter INSPECTION SUMMARY
07/09/2021 Letter INSPECTION SUMMARY
07/09/2021 Letter INSPECTION SUMMARY
07/09/2021 Letter INSPECTION SUMMARY
01/25/2022 Letter INSPECTION SUMMARY
01/25/2022 Letter INSPECTION SUMMARY
01/25/2022 Letter INSPECTION SUMMARY
01/25/2022 Letter INSPECTION SUMMARY
01/25/2022 Letter INSPECTION SUMMARY
01/25/2022 Letter INSPECTION SUMMARY
01/25/2022 Letter INSPECTION SUMMARY
01/25/2022 Letter INSPECTION SUMMARY
01/25/2022 Letter INSPECTION SUMMARY
01/31/2022 Scan_0031
02/04/2022 Letter INSPECTION SUMMARY
02/04/2022 Letter Field Certificate of Occupancy
02/04/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home