PRRES20253945
Building Permit - Residential
Temporary Occupancy
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSSES - UNFINISHED BASEMENT - STOP WORK ORDER generated on 10/30/2025 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER removed on 11/17/2025 12:00 AM by username 'Mitchell Schwarz'.
09/15/2025
09/23/2025
03/17/2026
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
BRUCER@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
BILL'S PLUMBING SERVICE LLC, Address:308 E PARK STREET, Phone:(913) 829-8213  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Sanitary Sewer Development Fee $2,398.00 $2,398.00 Paid 09/23/2025
Right of Way Permit Fee $85.00 $85.00 Paid 09/23/2025
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 09/23/2025
Water Tap Fee $4,080.00 $4,080.00 Paid 09/23/2025
Water Meter Fee $791.53 $791.53 Paid 09/23/2025
Valuation Fee New Single Family $1,758.64 $1,758.64 Paid 09/23/2025
Parks Impact Fee Residential Zone 2 $1,000.00 $1,000.00 Paid 09/23/2025
Not Ready Inspection Fee $75.00 $75.00 Paid 03/17/2026
Not Ready Inspection Fee $75.00 $75.00 Paid 03/17/2026
Not Ready Inspection Fee $75.00 $75.00 Paid 03/17/2026
Not Ready Inspection Fee $75.00 $75.00 Paid 03/17/2026
Temporary Occupancy Fee $50.00 $50.00 Paid 03/17/2026
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Pending
Occupancy Inspection - Codes Residential Pending
Misc
Corrective Action Required
03/17/2026
Final grade sod and splash blocks needed, sump must discharge 36” from foundation
Footing Inspection - Residential Failed 10/28/2025 10/28/2025
Misc
Corrective Action Required
10/28/2025
Inspection denied erosion control not in compliance
Erosion Control Inspection Residential Failed 10/28/2025 10/28/2025 10/28/2025
DCM5 ESC INSP DENIED
Corrective Action Required
10/28/2025
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. NO GRAVEL ENTRANCE Ensure protection around lot
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
10/28/2025
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Erosion Control Inspection Residential Failed - Stop Work 10/30/2025 10/30/2025 10/30/2025
DCM5 ESC INSP DENIED
Corrective Action Required
10/28/2025
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. NO GRAVEL ENTRANCE Ensure protection around lot
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
10/28/2025
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Erosion Control Inspection Residential Failed 11/7/2025 11/7/2025 11/07/2025
DCM5 ESC INSP DENIED
Corrective Action Required
10/30/2025
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. NO GRAVEL ENTRANCE Ensure protection around lot
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
10/30/2025
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Erosion Control Inspection Residential Not Ready 11/12/2025 11/12/2025 11/12/2025
DCM5 ESC INSP DENIED
Corrective Action Required
11/07/2025
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. NO GRAVEL ENTRANCE Ensure protection around lot
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
11/07/2025
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
11/12/2025
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
Erosion Control Inspection Residential Partial 11/17/2025 11/17/2025 11/17/2025
DCM5 ESC INSP DENIED
Resolved
11/17/2025
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. NO GRAVEL ENTRANCE Ensure protection around lot
DCM3 ESC REQUIRED 2 DAY
Resolved
11/17/2025
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM6 ESC INSP DENIED STREET CLEAN UP
Resolved
11/17/2025
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
Underslab Plumbing Inspection - Residential Passed 11/18/2025 11/18/2025 11/18/2025
Sewer Service Inspection - R Passed 11/24/2025 11/24/2025 11/24/2025
Water Service Inspection - R Passed 12/5/2025 12/5/2025 12/05/2025
All Rough Inspection - Residential Failed 12/23/2025 12/23/2025 12/23/2025
Misc
Corrective Action Required
12/23/2025
Inspection denied, no premises identification No re-inspection until full all rough
All Rough Inspection - Residential Not Ready 12/24/2025 12/24/2025 12/24/2025
Misc
Corrective Action Required
12/23/2025
Inspection denied, no premises identification No re-inspection until full all rough
Misc
Corrective Action Required
12/24/2025
-No Blue Prints on site
Electrical Service Inspection Not Ready 1/20/2026 1/20/2026 01/20/2026
Misc
Corrective Action Required
01/20/2026
-Ufer ground connections not listed for rebar And not installed to manufacture specifications
Gas Service Inspection - Residential Failed 1/20/2026 1/20/2026 01/20/2026
G2417.4 Test pressure measurement
Corrective Action Required
01/20/2026
INSPECTION, TESTING AND PURGING. Test pressure shall be measured with a manometer or with a pressure-measuring device designed and calibrated to read, record, or indicate a pressure loss caused by leakage during the pressure test period. The source of pressure shall be isolated before the pressure tests are made. Mechanical gauges used to measure test pressures shall have a range such that the highest end of the scale is not greater than five times the test pressure.
G2417.4.1 Test Pressure
Corrective Action Required
01/20/2026
INSPECTION, TESTING AND PURGING. AMENDED 7-945. The test pressure to be used shall be not less than one and one-half times the proposed maximum working pressure, but not less than 10 psig (68.9kPa) irrespective of design pressure. For welded piping, and for piping carrying gas at pressures in excess of fourteen (14) inches water column pressure, the test pressure shall not be less than 60 psig. Where the test pressure exceeds 125 psig (862 kPa gauge), the test pressure shall not exceed a value that produces a hoop stress in the piping greater than 50 percent of the specified minimum yield strength of the pipe.
Misc
Corrective Action Required
01/27/2026
Gas pressure at 5psi,
All Rough Inspection - Residential Failed 1/20/2026 1/20/2026 01/20/2026
Misc
Resolved
01/20/2026
Inspection denied, no premises identification No re-inspection until full all rough
Misc
Resolved
01/20/2026
-No Blue Prints on site
Misc
Corrective Action Required
01/20/2026
-missing anchor bolts SW garage wall -anchor bolt to be in the middle 1/3 of sill plate see N / N/E wall garage -missing hangers for trusses in garage -7.71 detail missing from plans -fire block wall space into furr down at pwdr room -fire block and all space into furr down at pantry back wall -missing stud at pantry entry -fire block to under floor landing area -fireblock top of hvac chases in flex room -land electrical at front porch -un cover covered from porch walls -missing truss hold down N primary bedroom wall -missing truss hold down S primary bed truss D2 -fireblock top of dead space into furr down primary bathroom -missing truss bracing throughout -nail trusses together to plans -provide blocking under kitchen island -ufer ground rod connections no listed for rebar connection and installed incorrectly -gas pipe ground clamp not installed correctly and does not appear to be correct size. (Check listing)
Footing Inspection - Residential Passed 01/27/2026
Misc
Resolved
01/27/2026
Inspection denied erosion control not in compliance
Gas Service Inspection - Residential Failed 1/27/2026 1/27/2026 01/27/2026
G2417.4 Test pressure measurement
Corrective Action Required
01/20/2026
INSPECTION, TESTING AND PURGING. Test pressure shall be measured with a manometer or with a pressure-measuring device designed and calibrated to read, record, or indicate a pressure loss caused by leakage during the pressure test period. The source of pressure shall be isolated before the pressure tests are made. Mechanical gauges used to measure test pressures shall have a range such that the highest end of the scale is not greater than five times the test pressure.
G2417.4.1 Test Pressure
Corrective Action Required
01/20/2026
INSPECTION, TESTING AND PURGING. AMENDED 7-945. The test pressure to be used shall be not less than one and one-half times the proposed maximum working pressure, but not less than 10 psig (68.9kPa) irrespective of design pressure. For welded piping, and for piping carrying gas at pressures in excess of fourteen (14) inches water column pressure, the test pressure shall not be less than 60 psig. Where the test pressure exceeds 125 psig (862 kPa gauge), the test pressure shall not exceed a value that produces a hoop stress in the piping greater than 50 percent of the specified minimum yield strength of the pipe.
Electrical Service Inspection Not Ready 1/27/2026 1/27/2026 01/27/2026
Misc
Corrective Action Required
01/20/2026
-Ufer ground connections not listed for rebar And not installed to manufacture specifications
All Rough Inspection - Residential Failed 1/27/2026 1/27/2026 01/27/2026
Misc
Corrective Action Required
01/20/2026
-missing truss hangers in garage -fire block to under floor landing area -fireblock top of hvac chases in flex room(seal gaps and penetrations) -un cover covered from porch walls -fireblock top of dead space into furr down primary bathroom (seal gaps and penetrations) -ufer ground rod connections no listed for rebar connection and installed incorrectly
All Rough Inspection - Residential Passed 1/29/2026 1/29/2026 01/29/2026
Misc
Resolved
01/29/2026
-missing truss hangers in garage -fire block to under floor landing area -ufer ground rod connections no listed for rebar connection and installed incorrectly
Electrical Service Inspection Passed 1/29/2026 1/29/2026 01/29/2026
Misc
Resolved
01/29/2026
-Ufer ground connections not listed for rebar And not installed to manufacture specifications
Gas Service Inspection - Residential Passed 1/29/2026 1/29/2026 01/29/2026
G2417.4 Test pressure measurement
Resolved
01/29/2026
INSPECTION, TESTING AND PURGING. Test pressure shall be measured with a manometer or with a pressure-measuring device designed and calibrated to read, record, or indicate a pressure loss caused by leakage during the pressure test period. The source of pressure shall be isolated before the pressure tests are made. Mechanical gauges used to measure test pressures shall have a range such that the highest end of the scale is not greater than five times the test pressure.
G2417.4.1 Test Pressure
Resolved
01/29/2026
INSPECTION, TESTING AND PURGING. AMENDED 7-945. The test pressure to be used shall be not less than one and one-half times the proposed maximum working pressure, but not less than 10 psig (68.9kPa) irrespective of design pressure. For welded piping, and for piping carrying gas at pressures in excess of fourteen (14) inches water column pressure, the test pressure shall not be less than 60 psig. Where the test pressure exceeds 125 psig (862 kPa gauge), the test pressure shall not exceed a value that produces a hoop stress in the piping greater than 50 percent of the specified minimum yield strength of the pipe.
Driveway Inspection Partial 2/13/2026 2/13/2026 02/13/2026
Misc
Informational
02/13/2026
2-13-26 Dustin A, dw has been formed and compacted. Approved to pour
Driveway Inspection Passed 2/20/2026 2/20/2026 02/20/2026
Misc
Informational
02/13/2026
2-13-26 Dustin A, dw has been formed and compacted. Approved to pour 2-20-26 Dustin A, dw was poured to city specs
Plot Plan Inspection Passed 3/17/2026 03/17/2026
Occupancy Inspection - Codes Residential Ready for Temp CO 3/17/2026 3/17/2026 03/17/2026
Misc
Corrective Action Required
03/17/2026
Final grade sod and splash blocks needed, sump must discharge 36” from foundation
Documents & Images
Date Uploaded File Type Document Name
09/15/2025 BY #2090 - PERMIT APP
09/18/2025 Permit Codes Residential Plan Review
09/18/2025 Approved Plans APPROVED PLANS
09/18/2025 Approved Plans APPROVED TRUSS LAYOUT
09/18/2025 Approved Plans APPROVED TRUSS PACKET
09/23/2025 Plot Plan APPROVED PLOT PLAN
09/23/2025 Permit Codes Residential Plan Review
09/23/2025 Permit DS Building Permit
09/23/2025 Receipt Receipt for transaction:2025-007302
10/27/2025 3RD Party Insp Report 2090 Bailey Farms - FTNG - Stamped
10/28/2025 Letter INSPECTION SUMMARY
10/28/2025 Letter INSPECTION SUMMARY
10/30/2025 Letter Stop Work Order
11/07/2025 Letter INSPECTION SUMMARY
11/12/2025 Letter INSPECTION SUMMARY
11/17/2025 Letter INSPECTION SUMMARY
11/18/2025 Letter INSPECTION SUMMARY
11/24/2025 Letter INSPECTION SUMMARY
12/05/2025 Letter INSPECTION SUMMARY
12/23/2025 Letter INSPECTION SUMMARY
01/19/2026 3RD Party Insp Report 2090 BAILEY FARMS - FIELD LETTER
01/20/2026 Letter INSPECTION SUMMARY
01/20/2026 Letter INSPECTION SUMMARY
01/20/2026 Letter INSPECTION SUMMARY
01/20/2026 Letter INSPECTION SUMMARY
01/27/2026 BY #2090 - HOUSE PLAN SET - MU 01_21_26
01/27/2026 Letter INSPECTION SUMMARY
01/27/2026 Letter INSPECTION SUMMARY
01/27/2026 Letter INSPECTION SUMMARY
01/27/2026 Letter INSPECTION SUMMARY
01/27/2026 Letter INSPECTION SUMMARY
01/29/2026 BY 2090 Truss Detail
01/29/2026 Letter INSPECTION SUMMARY
01/29/2026 Letter INSPECTION SUMMARY
01/29/2026 Letter INSPECTION SUMMARY
02/13/2026 Letter INSPECTION SUMMARY
02/20/2026 Letter INSPECTION SUMMARY
03/17/2026 Letter INSPECTION SUMMARY
03/17/2026 Letter INSPECTION SUMMARY
03/17/2026 Certificate/License Codes Temporary Certificate of Occupancy
03/17/2026 Receipt Receipt for transaction:2026-001586
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home