Permit Application Status

PRRES20251909


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20251909
Building Permit - Residential
Temporary Occupancy
NEW SINGLE FAMILY
NEW HOUSE. UNFINISHED BASEMENT. UNCOVERED PATIO. ROOF TRUSSES.
05/09/2025
05/19/2025
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ZACHARY W MOFFETT, Address:2113 SPARROW CIRCLE   
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
taylor@summithomeskc.com  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Water Tap Fee $3,973.00 $3,973.00 Paid 05/19/2025
Water Meter Fee $748.03 $748.03 Paid 05/19/2025
Sanitary Sewer Development Fee $2,285.00 $2,285.00 Paid 05/19/2025
Right of Way Permit Fee $85.00 $85.00 Paid 05/19/2025
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 05/19/2025
Valuation Fee New Single Family $1,970.26 $1,970.26 Paid 05/19/2025
Not Ready Inspection Fee $75.00 $75.00 Paid 10/15/2025
Temporary Occupancy Fee $50.00 $50.00 Paid 10/15/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Plot Plan Inspection Pending
Erosion Control Inspection Residential Pending
DCM5 ESC INSP DENIED
Corrective Action Required
06/06/2025
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. -INSTALL GRAVEL ENTRANCE
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
06/06/2025
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Occupancy Inspection - Codes Residential Pending
Misc
Corrective Action Required
10/15/2025
-final grade and sod -Address pending driveway inspection -splash blocks and sump pump discharge to extend 36” from foundation -seal all exterior penetrations top of meter
Footing Inspection - Residential Passed 5/29/2025 05/29/2025
Erosion Control Inspection Residential Partial 5/29/2025 05/29/2025
Underslab Plumbing Inspection - Residential Not Ready 6/6/2025 6/6/2025 06/06/2025
Misc
Corrective Action Required
06/06/2025
Erosion control not in compliance inspection denied -Provide gravel entrance -provide backfill for viewing to inspect
Erosion Control Inspection Residential Failed 6/6/2025 6/6/2025 06/06/2025
DCM5 ESC INSP DENIED
Corrective Action Required
06/06/2025
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. -INSTALL GRAVEL ENTRANCE
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
06/06/2025
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Sewer Service Inspection - R Passed 6/9/2025 6/9/2025 06/09/2025
Water Service Inspection - R Passed 6/10/2025 6/10/2025 06/10/2025
Underslab Plumbing Inspection - Residential Passed 6/11/2025 6/11/2025 06/11/2025
Misc
Resolved
06/11/2025
Erosion control not in compliance inspection denied -Provide gravel entrance -provide backfill for viewing to inspect
Electrical Service Inspection Passed 7/31/2025 7/31/2025 07/31/2025
Gas Service Inspection - Residential Passed 7/31/2025 7/31/2025 07/31/2025
All Rough Inspection - Residential Failed 7/31/2025 7/31/2025 07/31/2025
Misc
Corrective Action Required
07/31/2025
-provide attic access above double car garage -provide anchor bolts with in 12” of plate breaks but not closer than 7x the diameter of the bolt -seal penetrations into furr down at garage back wall -complete electrical at garage entry -fireblock wall space to stair landing floor space -seal top of dead space at bed 3 -complete plumbing for primary bath vanities -nail E3 truss together to plans -missing truss hold-downs on H4 trusses -nail H3 truss together to plans -address holes drilled closer than 2” to one another at double 2x at bottom of stairs -address holes drilled in floor joist above electrical panel where drilled closer than 2” from one another -stud pack at stairs to be of 3 full height studs -provide bracing under kitchen island
All Rough Inspection - Residential Passed 8/5/2025 8/5/2025 08/05/2025
Misc
Resolved
08/05/2025
-provide attic access above double car garage -provide anchor bolts with in 12” of plate breaks but not closer than 7x the diameter of the bolt -seal penetrations into furr down at garage back wall -complete electrical at garage entry -fireblock wall space to stair landing floor space -seal top of dead space at bed 3 -complete plumbing for primary bath vanities -nail E3 truss together to plans -missing truss hold-downs on H4 trusses -nail H3 truss together to plans -address holes drilled closer than 2” to one another at double 2x at bottom of stairs -address holes drilled in floor joist above electrical panel where drilled closer than 2” from one another -stud pack at stairs to be of 3 full height studs -provide bracing under kitchen island
Driveway Inspection Partial 8/28/2025 8/28/2025 08/28/2025
Misc
Informational
08/28/2025
8-28-25 Dustin A, dw is formed and compacted. Approved to pour
Driveway Inspection Passed 9/5/2025 9/5/2025 09/05/2025
Misc
Informational
08/28/2025
8-28-25 Dustin A, dw is formed and compacted. Approved to pour 9/5/25 Tyler S. DW is in compliance with city specs. Pass.
Occupancy Inspection - Codes Residential Failed 10/13/2025 10/13/2025 10/13/2025
Misc
Corrective Action Required
10/13/2025
No access, inspection denied
Occupancy Inspection - Codes Residential Ready for Temp CO 10/15/2025 10/15/2025 10/15/2025
Misc
Corrective Action Required
10/13/2025
-final grade and sod -Address pending driveway inspection -splash blocks and sump pump discharge to extend 36” from foundation -seal all exterior penetrations top of meter
Documents & Images
Date Uploaded File Type Document Name
05/09/2025 BY #180 - PERMIT APP
05/19/2025 Approved Plans APPROVED PLANS
05/19/2025 Plot Plan APPROVED PLOT PLAN
05/19/2025 Approved Plans APPROVED TRUSS PACKAGE
05/19/2025 Approved Plans APPROVED TRUSS LAYOUT
05/19/2025 Permit Codes Residential Plan Review
05/19/2025 Permit DS Building Permit
05/19/2025 Receipt Receipt for transaction:2025-003513
05/28/2025 3RD Party Insp Report THIRD PARTY FOOTING INSPECTION
05/29/2025 Letter INSPECTION SUMMARY
05/29/2025 Letter INSPECTION SUMMARY
06/06/2025 Letter INSPECTION SUMMARY
06/06/2025 Letter INSPECTION SUMMARY
06/09/2025 Letter INSPECTION SUMMARY
06/10/2025 Letter INSPECTION SUMMARY
06/11/2025 Letter INSPECTION SUMMARY
07/31/2025 Letter INSPECTION SUMMARY
07/31/2025 Letter INSPECTION SUMMARY
07/31/2025 Letter INSPECTION SUMMARY
08/05/2025 180 Bailey Farms- Field Issue 250804
08/05/2025 Letter INSPECTION SUMMARY
08/28/2025 Letter INSPECTION SUMMARY
09/05/2025 Letter INSPECTION SUMMARY
10/13/2025 Letter INSPECTION SUMMARY
10/15/2025 Letter INSPECTION SUMMARY
10/15/2025 Certificate/License Codes Temporary Certificate of Occupancy
10/15/2025 Receipt Receipt for transaction:2025-007791
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home