Summary
PRRES20250046
Building Permit - Residential
Temporary Occupancy
NEW SINGLE FAMILY
NEW SINGLE FAMILY HOME - SLAB ON GRADE, COVERED PORCH
01/02/2025
06/25/2025
Locations
Contacts
Avital Homes, LLC, Address:7500 W 151st Street, #23100, Phone:(816) 914-7128  
Doug Jenson, Address:11010 Nora Dodge Dr, Phone:(816) 266-0685  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
RED DOG ELECTRIC SERVICES, Address:PO BOX 1, Phone:(913) 208-4816  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,204.79 $1,204.79 Paid 04/03/2025
Right of Way Permit Fee $85.00 $85.00 Paid 04/03/2025
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 04/03/2025
Water Tap Fee $3,973.00 $3,973.00 Paid 04/03/2025
Water Meter Fee $748.03 $748.03 Paid 04/03/2025
Sanitary Sewer Development Fee $2,285.00 $2,285.00 Paid 04/03/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Piers/Caissons Inspection - Residential Pending
Plot Plan Inspection Pending
Gas Service Inspection - Residential Pending
Footing Inspection - Residential Pending
Misc
Corrective Action Required
07/24/2025
provide engineered report for undermined footing.
Erosion Control Inspection Residential Pending
Misc
Corrective Action Required
02/09/2026
Maintain overgrown vegetation being addressed under sub permit.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
02/09/2026
2-5-26 Dustin A, Silt fence needs to be repaired EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. 2-9-26 Dustin A, Corrections made
Occupancy Inspection - Codes Residential Pending
Misc
Corrective Action Required
02/19/2026
Final grade Ensure 6” clearance from siding to grade -Sod -Splash blocks
Erosion Control Inspection Residential Partial 5/13/2025 5/13/2025 05/13/2025
Misc
Corrective Action Required
05/13/2025
Maintain overgrown vegetation being addressed under sub permit.
Footing Inspection - Residential Failed 5/16/2025 5/16/2025 05/16/2025
Misc
Corrective Action Required
05/16/2025
-Plans call for #4 C shaped ties 24” OC -#3 ties 24” OC INSTALLED completely wrapping footing. “O Shaped”
Footing Inspection - Residential Passed 5/21/2025 5/21/2025 05/21/2025
Misc
Resolved
05/21/2025
-Plans call for #4 C shaped ties 24” OC -#3 ties 24” OC INSTALLED completely wrapping footing. “O Shaped”
Underslab Plumbing Inspection - Residential Passed 5/28/2025 5/28/2025 05/28/2025
All Rough Inspection - Residential Failed 7/11/2025 7/11/2025 07/11/2025
Misc
Corrective Action Required
07/11/2025
PORTAL FRAME ONLY - EXTIERIOR SHEETING OK TO COVER ON PFH
Sewer Service Inspection - R Passed 7/16/2025 7/16/2025 07/16/2025
Water Service Inspection - R Passed 7/24/2025 7/24/2025 07/24/2025
Footing Inspection - Residential Failed 7/24/2025 7/24/2025 07/24/2025
Misc
Corrective Action Required
07/24/2025
provide engineered report for undermined footing.
All Rough Inspection - Residential Failed 9/12/2025 9/12/2025 09/12/2025
Misc
Resolved
09/12/2025
PORTAL FRAME ONLY - EXTIERIOR SHEETING OK TO COVER ON PFH
Misc
Corrective Action Required
09/12/2025
Truss plans must be city approved. -fireblock garage walls into furr down -bonding screw missing at metallic box’s - CS-Pf nailing at rear dining room spacing incorrectly nailed -seal penetrations and gaps in draft stopping -T04 trusses have no bearing -protect all wiring within 6’ of attic access -bed 1 outlet missing and spacing incorrect -provide hold downs both sides of double truss above bed 1 closet -protect dryer vent through stud penetrations -missing hold downs for trusses above dead space at laundry -land all ground and neutrals in panel -missing ufer ground connection -bond meter can -se cable not ran
All Rough Inspection - Residential Failed 9/18/2025 9/18/2025 09/18/2025
Misc
Corrective Action Required
09/12/2025
Truss plans must be city approved. -fireblock garage walls into furr down seal penetrations and gaps in draft stopping -provide hold downs both sides of double truss above bed 1 closet ( not catching both plates)
Electrical Service Inspection Passed 9/18/2025 9/18/2025 09/18/2025
All Rough Inspection - Residential Failed 11/3/2025 11/3/2025 11/03/2025
Misc
Corrective Action Required
09/18/2025
Truss plans do not match trusses on site. -fireblock garage walls into furr down
All Rough Inspection - Residential Passed 11/17/2025 11/17/2025 11/17/2025
Misc
Resolved
11/17/2025
Truss plans do not match trusses on site. -fireblock garage walls into furr down
All Rough Inspection - Residential Passed 12/3/2025 12/3/2025 12/03/2025
Driveway Inspection Partial 12/30/2025 12/30/2025 12/30/2025
Misc
Corrective Action Required
12/30/2025
12-30-25 Dustin A, Dw has been formed and compacted. Good to pour as long as ground temp is above 32 degrees . Please call to have ground temp checked before pouring.
Driveway Inspection Partial 1/5/2026 1/5/2026 01/05/2026
Misc
Corrective Action Required
12/30/2025
12-30-25 Dustin A, Dw has been formed and compacted. Good to pour as long as ground temp is above 32 degrees . Please call to have ground temp checked before pouring. 1-5-26 Dustin A, 12-30-25 Dustin A, Dw has been formed and compacted. Good to pour as long as ground temp is above 32 degrees .
Driveway Inspection Passed 1/22/2026 1/22/2026 01/22/2026
Misc
Corrective Action Required
01/05/2026
12-30-25 Dustin A, Dw has been formed and compacted. Good to pour as long as ground temp is above 32 degrees . Please call to have ground temp checked before pouring. 1-5-26 Dustin A, 12-30-25 Dustin A, Dw has been formed and compacted. Good to pour as long as ground temp is above 32 degrees . 1-22-26 Dustin A, DW has been poured to city specs
Sidewalk Inspection Partial 01/22/2026
Misc
Corrective Action Required
01/22/2026
1-22-26 Dustin A, SW has been formed and compacted approved to pour
Sidewalk Inspection Passed 2/5/2026 2/5/2026 02/05/2026
Misc
Corrective Action Required
01/22/2026
1-22-26 Dustin A, SW has been formed and compacted approved to pour 2-5-26 Dustin A, Sw has been poured to city specs. Slopes were in compliance.
Erosion Control Inspection Residential Failed 2/5/2026 2/5/2026 02/05/2026
Misc
Corrective Action Required
05/13/2025
Maintain overgrown vegetation being addressed under sub permit.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
02/05/2026
2-5-26 Dustin A, Silt fence needs to be repaired EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Erosion Control Inspection Residential Partial 2/9/2026 2/9/2026 02/09/2026
Misc
Corrective Action Required
02/05/2026
Maintain overgrown vegetation being addressed under sub permit.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
02/05/2026
2-5-26 Dustin A, Silt fence needs to be repaired EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. 2-9-26 Dustin A, Corrections made
Occupancy Inspection - Codes Residential Failed 2/18/2026 2/18/2026 02/18/2026
Misc
Corrective Action Required
02/18/2026
Final grade Ensure 6” clearance from siding to grade -Sod -Splash blocks -all garage doors to be self closing and Latching -missing gaskets at garage door
Occupancy Inspection - Codes Residential Temporary C of O 2/19/2026 2/19/2026 02/19/2026
Misc
Corrective Action Required
02/18/2026
Final grade Ensure 6” clearance from siding to grade -Sod -Splash blocks
Documents & Images
Date Uploaded File Type Document Name
01/02/2025 Application Form J Permit Application Signed
01/02/2025 Application Form J Tax application
02/21/2025 Approved Plans Approved Final Grading Plan Lots 1 -12 Reserve at Blackwell
03/31/2025 Plans 21075_Blackwell Reserve_Bldg J CDs_250312
04/03/2025 Receipt Receipt for transaction:2025-002030
04/03/2025 Letter DS Building Permit
04/03/2025 Approved Plans APPROVED J PLANS
05/13/2025 Letter INSPECTION SUMMARY
05/16/2025 Letter INSPECTION SUMMARY
05/20/2025 25-0227_23090 Blackwell_Struct_Rev#3 (Footing Changes)
05/20/2025 25-0227_Reunion at Blackwell_Struct_Rev#3 Narrative (Footing Change)
05/21/2025 Letter INSPECTION SUMMARY
05/28/2025 Letter INSPECTION SUMMARY
07/11/2025 Letter INSPECTION SUMMARY
07/16/2025 Letter INSPECTION SUMMARY
07/24/2025 Letter INSPECTION SUMMARY
07/24/2025 Letter INSPECTION SUMMARY
08/04/2025 (SI inspections on footing back fill) 23-1200-dr-07_29_2025_Reserve at Blackwell
09/12/2025 Building J Truss seals
09/12/2025 Building J Roof Truss
09/12/2025 Building J Floor Truss
09/12/2025 Letter INSPECTION SUMMARY
09/18/2025 QLT QU02705_RESERVE BLDG J_REFRESHED_11272024 MO 1 (3)
09/18/2025 Letter INSPECTION SUMMARY
09/18/2025 Letter INSPECTION SUMMARY
10/29/2025 Approved Plans Approved Trusses J
10/31/2025 QLT QU02705 - PRODUCTION SET_04162025 MO mod 1 (3) (2)
11/03/2025 Letter INSPECTION SUMMARY
11/13/2025 Approved Plans Approved Trusses J - Lot 8
11/17/2025 Letter INSPECTION SUMMARY
11/17/2025 Approved Plans Truss repair doc
12/02/2025 Gyp Board at Stair Stringer Struct Response_Reserves at Blackwell
12/03/2025 Approved Plans Approved - Gyp Board at Stair Stringer Struct Response_Reserves at Blackwell
12/30/2025 Letter INSPECTION SUMMARY
01/05/2026 Letter INSPECTION SUMMARY
01/22/2026 Letter INSPECTION SUMMARY
01/22/2026 Letter INSPECTION SUMMARY
02/05/2026 Letter INSPECTION SUMMARY
02/05/2026 Letter INSPECTION SUMMARY
02/05/2026 Letter INSPECTION SUMMARY
02/06/2026 Engineer Report/Study Stand engineering Structural letter for Reserve buildings
02/09/2026 Letter INSPECTION SUMMARY
02/18/2026 Letter INSPECTION SUMMARY
02/18/2026 Letter INSPECTION SUMMARY
02/19/2026 Certificate/License Codes Temporary Certificate of Occupancy
03/16/2026 Approved Plans Approved truss revisions
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home