Permit Application Status

PRRES20244650


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20244650
Building Permit - Residential
Certificate of Occupancy
NLV PERGOLA PARK LLC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - COVERED PORCH STOP WORK ORDER generated on 01/23/2025 12:00 AM by username 'Shawn Hoffman'. STOP WORK ORDER removed on 01/28/2025 12:00 AM by username 'Shawn Hoffman'.
08/30/2024
09/18/2024
03/04/2025
08/22/2025
Locations
Contacts
BELLAH HOMES LLC, Address:P O BOX 346, Phone:(816) 697-2870  
NLV PERGOLA PARK LLC, Address:3152 SW GRANDSTAND CIR  
Paul Miller, Address:P.O. Box 346, Phone:(816) 786-5050  
TROY@BELLAHHOMES.COM  
AFC HEATING AND COOLING, Address:824 NW MAIN ST , Phone:(816) 347-8388  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Sanitary Sewer Development Fee $2,285.00 $2,285.00 Paid 09/18/2024
Right of Way Permit Fee $85.00 $85.00 Paid 09/18/2024
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 09/18/2024
Water Tap Fee $3,973.00 $3,973.00 Paid 09/18/2024
Water Meter Fee $748.03 $748.03 Paid 09/18/2024
Valuation Fee New Single Family $1,626.93 $1,626.93 Paid 09/18/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Failed 10/2/2024 10/02/2024
Misc
Corrective Action Required
10/02/2024
- TRIM ALL TALL VEGETATION ON LOT
Footing Inspection - Residential Passed 10/2/2024 10/02/2024
Misc
Corrective Action Required
10/02/2024
INSPECTION PERFORMED BY THIRD PARTY
Underslab Plumbing Inspection - Residential Failed 10/10/2024 10/10/2024 10/10/2024
R506.2 Site preparation
Corrective Action Required
10/10/2024
CONCRETE FLOORS (ON GROUND). The area within the foundation walls shall have all vegetation, top soil and foreign material removed.
Resolved
10/10/2024
Erosion Control Inspection Residential Failed 10/10/2024 10/10/2024
Misc
Resolved
10/10/2024
- TRIM ALL TALL VEGETATION ON LOT
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
10/10/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - REPAIR SILT FENCE AT FRONT OF LOT - REMOVE TRASH AND DEBRIS FROM LOT.
Underslab Plumbing Inspection - Residential Passed 10/14/2024 10/14/2024 10/14/2024
R506.2 Site preparation
Resolved
10/14/2024
CONCRETE FLOORS (ON GROUND). The area within the foundation walls shall have all vegetation, top soil and foreign material removed.
Erosion Control Inspection Residential Partial 10/14/2024 10/14/2024
DCM2 ESC DEFICIENT INSTALLATION
Resolved
10/14/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - REPAIR SILT FENCE AT FRONT OF LOT - REMOVE TRASH AND DEBRIS FROM LOT.
Misc
Corrective Action Required
10/14/2024
- Erosion control in place at time f inspection.
Sewer Service Inspection - R Passed 10/24/2024 10/24/2024 10/24/2024
Water Service Inspection - R Partial 10/25/2024 10/25/2024 10/25/2024
Misc
Corrective Action Required
10/25/2024
Partial, poly out of foundation 30’
Water Service Inspection - R Passed 10/28/2024 10/28/2024 10/28/2024
Misc
Resolved
10/28/2024
Partial, poly out of foundation 30’
All Rough Inspection - Residential Failed - Stop Work 1/23/2025 1/23/2025 01/23/2025
Misc
Corrective Action Required
01/23/2025
INSPECTION DENIDE EROSION CONTROL NOT IN COMPLIANCE
Misc
Resolved
01/23/2025
Erosion Control Inspection Residential Failed 1/23/2025 01/23/2025
Misc
Resolved
01/23/2025
- Erosion control in place at time f inspection.
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
01/23/2025
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Erosion Control Inspection Residential Failed 1/28/2025 01/28/2025
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
01/28/2025
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Misc
Corrective Action Required
01/28/2025
- Provide gravel filter at driveway - protect stock pile
All Rough Inspection - Residential Failed 1/28/2025 1/28/2025 01/28/2025
Misc
Resolved
01/28/2025
INSPECTION DENIDE EROSION CONTROL NOT IN COMPLIANCE
Misc
Corrective Action Required
01/28/2025
- Protect wiring under windows in bedroom 2 - Fire block top plate above refrigerator ( double wall) - Provide second stud under double 2x10” above refrigerator - Fire block top of chase in basement shower - Fire block basement fur out walls every 10’ vertically with approved material ( pressure treated)
Electrical Service Inspection Passed 1/28/2025 1/28/2025 01/28/2025
Gas Service Inspection - Residential Passed 1/28/2025 1/28/2025 01/28/2025
All Rough Inspection - Residential Passed 1/31/2025 1/31/2025 01/31/2025
Misc
Resolved
01/31/2025
- Protect wiring under windows in bedroom 2 - Fire block top plate above refrigerator ( double wall) - Provide second stud under double 2x10” above refrigerator - Fire block top of chase in basement shower - Fire block basement fur out walls every 10’ vertically with approved material ( pressure treated)
Sidewalk Inspection Failed 5/28/2025 5/28/2025 05/28/2025
Misc
Informational
05/28/2025
05-28-25 Jamie S, SW does not have the required 3 inches of aggregate in spots and has standing water on the south side.
Sidewalk Inspection Failed 5/30/2025 5/30/2025 05/30/2025
Misc
Informational
05/28/2025
05-28-25 Jamie S, SW does not have the required 3 inches of aggregate in spots and has standing water on the south side. 5-30-25 DP. SW does not have required depth. Talked to contractor and he is going to fix.
Sidewalk Inspection Partial 6/2/2025 6/2/2025 06/02/2025
Misc
Informational
05/30/2025
05-28-25 Jamie S, SW does not have the required 3 inches of aggregate in spots and has standing water on the south side. 5-30-25 DP. SW does not have required depth. Talked to contractor and he is going to fix. 6-2-25 DP. Contractor has SW correct now. Approved to pour
Erosion Control Inspection Residential Passed 7/14/2025 07/14/2025
Misc
Resolved
07/14/2025
- Provide gravel filter at driveway - protect stock pile
Plot Plan Inspection Passed 7/14/2025 07/14/2025
Occupancy Inspection - Codes Residential Failed 7/14/2025 7/14/2025 07/14/2025
Miscellaneous Correction
Corrective Action Required
07/14/2025
INSPECTION DENIDE NO POSTED ADDRESS
Occupancy Inspection - Codes Residential Failed 8/6/2025 8/6/2025 08/06/2025
Miscellaneous Correction
Resolved
08/06/2025
INSPECTION DENIDE NO POSTED ADDRESS
Misc
Corrective Action Required
08/06/2025
- Seal penetration exterior at cat5 by electrical meter - Land sewer trace wire to grade - provide splash pads at down spout - Change receptacle at water heater to single and mark non GFCI - Provide security screws at all exterior doors per city ordinance - Seal exterior rim board at A/C intake/ exhaust
Sidewalk Inspection Passed 6/9/2025 8/22/2025 08/22/2025
Misc
Informational
06/02/2025
05-28-25 Jamie S, SW does not have the required 3 inches of aggregate in spots and has standing water on the south side. 5-30-25 DP. SW does not have required depth. Talked to contractor and he is going to fix. 6-2-25 DP. Contractor has SW correct now. Approved to pour 08/22/25 Jamie S, SW is compliant with city standards.
Occupancy Inspection - Codes Residential Full C of O 8/22/2025 8/22/2025 08/22/2025
Misc
Resolved
08/22/2025
- Pending sidewalk inspection.
Documents & Images
Date Uploaded File Type Document Name
08/30/2024 Lot 95 Permit Application
08/30/2024 Lot 95 Tax Application
09/05/2024 Permit Codes Residential Plan Review
09/09/2024 Plot Plan APPROVED PLOT PLAN
09/09/2024 Approved Plans APPROVED PLANS
09/09/2024 Permit Codes Residential Plan Review
09/18/2024 Permit DS Building Permit
09/18/2024 Receipt Receipt for transaction: 2024-007761
10/01/2024 1021 SW Redbuck Cir LSMO Footing Inspection Report 9-30-24
10/02/2024 Letter INSPECTION SUMMARY
10/02/2024 Letter INSPECTION SUMMARY
10/10/2024 Letter INSPECTION SUMMARY
10/10/2024 Letter INSPECTION SUMMARY
10/14/2024 Letter INSPECTION SUMMARY
10/14/2024 Letter INSPECTION SUMMARY
10/24/2024 Letter INSPECTION SUMMARY
10/25/2024 Letter INSPECTION SUMMARY
10/28/2024 Letter INSPECTION SUMMARY
01/23/2025 Letter INSPECTION SUMMARY
01/23/2025 Letter Stop Work Order
01/28/2025 Letter INSPECTION SUMMARY
01/28/2025 Letter INSPECTION SUMMARY
01/28/2025 Letter INSPECTION SUMMARY
01/28/2025 Letter INSPECTION SUMMARY
01/31/2025 Letter INSPECTION SUMMARY
05/28/2025 Letter INSPECTION SUMMARY
05/30/2025 Letter INSPECTION SUMMARY
06/02/2025 Letter INSPECTION SUMMARY
07/14/2025 Letter INSPECTION SUMMARY
07/14/2025 Letter INSPECTION SUMMARY
07/14/2025 Letter INSPECTION SUMMARY
08/06/2025 Letter INSPECTION SUMMARY
08/22/2025 Letter Field Certificate of Occupancy
08/22/2025 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home