Summary
PRRES20242856
Building Permit - Residential
Issued
NEW DUPLEX
NEW DUPLEX. FINISHED/UNFINISHED BASEMENT. SUSPENDED SLAB. COVERED PATIO.
06/04/2024
07/11/2024
12/08/2024
Locations
Contacts
ROCK CREEK HOMES, Address:6126 METCALF LANE, Phone:(913) 522-1945  
Kevin Guinan, Address:6126 Metcalf Lane  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
PRIDE SERVICES INC, Address:3842 GEORGIA TERR, Phone:(785) 242-9700  
BILL'S PLUMBING SERVICE LLC, Address:308 E PARK STREET, Phone:(913) 829-8213  
KEVIN@ROCKCREEKHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New Duplex $2,586.73 $2,586.73 Paid 07/11/2024
8331401-Water Tap Fee $7,946.00 $7,946.00 Paid 07/11/2024
8350015-Water Meter Fee $1,496.06 $1,496.06 Paid 07/11/2024
8331507-Sanitary Sewer Development Fee $4,570.00 $4,570.00 Paid 07/11/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 07/11/2024
7232302-Residential License Tax Fee $1,240.32 $1,240.32 Paid 07/11/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Plot Plan Inspection Pending
Foundation Inspection - Commercial Pending
Occupancy Inspection - Codes Residential Pending
Erosion Control Inspection Residential Pending
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
10/04/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Remove loose trash from the lot and trash that has blown to the lots to the north
Driveway Inspection Pending
Misc
Informational
03/03/2025
3-3-25 BR Driveway is formed with aggregate is place and compacted ready for concrete.
Footing Inspection - Residential Passed 8/1/2024 08/01/2024
Erosion Control Inspection Residential Partial 8/1/2024 08/01/2024
Misc
Informational
08/01/2024
-Erosion control was in compliance at the time of the inspection
Water Service Inspection - R Partial 8/20/2024 08/20/2024
Misc
Corrective Action Required
08/20/2024
- poly out of foundation 20' on 1412
Sewer Service Inspection - R Partial 8/20/2024 8/20/2024 08/20/2024
Misc
Informational
08/20/2024
- 1412 Appoved only
Sewer Service Inspection - R Passed 8/21/2024 08/21/2024
Misc
Informational
08/20/2024
- 1412 and 1414 Appoved
Underslab Electrical Inspection - Residential Passed 8/21/2024 8/21/2024 08/21/2024
ELECTRICAL
Informational
08/21/2024
- Conduit for service from nrth side of 1414 to 1412 Approved
Water Service Inspection - R Passed 8/22/2024 08/22/2024
Misc
Informational
08/22/2024
1412 and 1414 Approved
Underslab Plumbing Inspection - Residential Passed 9/3/2024 9/3/2024 09/03/2024
Misc
Corrective Action Required
09/03/2024
1412 and 1414
Rated Assembly Inspection Failed 9/30/2024 9/30/2024 09/30/2024
Miscellaneous Correction
Corrective Action Required
09/30/2024
Both sides - Spots in the field are missing fasteners and fasteners are not installed on the edges along the rafters Slid plywood in the attic back for a proper screw inspection
Suspended Slab Inspection Failed 9/30/2024 09/30/2024
Miscellaneous Correction
Corrective Action Required
09/30/2024
Suspended slab was covered without a city inspection. Have an engineers letter uploaded addressing missing inspection I tried calling twice today to talk to Kevin about this missing report
Rated Assembly Inspection Partial 10/2/2024 10/2/2024 10/02/2024
Miscellaneous Correction
Corrective Action Required
09/30/2024
Attic fire separation wall: -Screw pattern OK; however, extend the fire separation wall through roof soffit
Suspended Slab Inspection Passed 10/4/2024 10/04/2024
Miscellaneous Correction
Resolved
10/04/2024
Suspended slab was covered without a city inspection. Have an engineers letter uploaded addressing missing inspection I tried calling twice today to talk to Kevin about this missing report
Miscellaneous Correction
Informational
10/04/2024
Suspended slab passed by a third party
Erosion Control Inspection Residential Failed 10/4/2024 10/04/2024
Misc
Resolved
10/04/2024
-Erosion control was in compliance at the time of the inspection
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
10/04/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Remove loose trash from the lot and trash that has blown to the lots to the north
Rated Assembly Inspection Partial 10/17/2024 10/17/2024 10/17/2024
Miscellaneous Correction
Resolved
10/17/2024
Attic fire separation wall: -Screw pattern OK; however, extend the fire separation wall through roof soffit
MISC
Corrective Action Required
10/17/2024
INSPECTION OF ATTIC SPACE AND RIM BOARD 1412 - Fire caulk gap in mechanical room at rim board 1414 - Seal gap above basement bathroom at rim board
Electrical Service Inspection Passed 11/8/2024 11/8/2024 11/08/2024
Misc
Informational
11/08/2024
1412, 1414
Rated Assembly Inspection Partial 11/8/2024 11/8/2024 11/08/2024
MISC
Corrective Action Required
10/17/2024
INSPECTION OF ATTIC SPACE AND RIM BOARD 1412, 1414 approved
Gas Service Inspection - Residential Passed 11/8/2024 11/8/2024 11/08/2024
Misc
Informational
11/08/2024
1412, 1414
All Rough Inspection - Residential Failed 11/8/2024 11/8/2024 11/08/2024
Misc
Corrective Action Required
11/08/2024
1412 - tighten anchor bolts garage 1214 - top plat not tie in at entry / bedroom 2 (strap) - Nail 2x6 stud pack together at kitchen refrigerator under double LVL - Fire block return air space wire penetrations at basement bathroom
All Rough Inspection - Residential Passed 11/12/2024 11/12/2024 11/12/2024
Misc
Resolved
11/12/2024
1412 - tighten anchor bolts garage 1214 - top plat not tie in at entry / bedroom 2 (strap) - Nail 2x6 stud pack together at kitchen refrigerator under double LVL - Fire block return air space wire penetrations at basement bathroom
Rated Assembly Inspection Passed 12/2/2024 12/2/2024 12/02/2024
MISC
Informational
12/02/2024
Both 1412, 1414 approved
Driveway Inspection Passed 3/3/2025 3/3/2025 03/11/2025
Misc
Informational
03/03/2025
3-3-25 BR Driveway is formed with aggregate is place and compacted ready for concrete. 3-11-25 BR Driveway is constructed to LS specifications.
Sidewalk Inspection Partial 4/29/2025 4/29/2025 04/29/2025
Misc
Informational
04/29/2025
4/29/25 RH. South Sidewalk is formed up and approved to pour, contractor was told to replace straw waddles and clean up street. North Sidewalk had oversaturated soil and was holding water, not approved to pour.
Sidewalk Inspection Passed 5/6/2025 5/6/2025 05/06/2025
Misc
Informational
04/29/2025
4/29/25 RH. South Sidewalk is formed up and approved to pour, contractor was told to replace straw waddles and clean up street. North Sidewalk had oversaturated soil and was holding water, not approved to pour. 5-6-25 RH. Sidewalk was poured and passed inspecition.
Documents & Images
Date Uploaded File Type Document Name
06/04/2024 Application - Lot 48
06/04/2024 Tax Form - Lot 48
06/11/2024 Permit Codes Residential Plan Review
06/26/2024 Plot Plan APPROVED PLOT PLAN
06/27/2024 Approved Plans APPROVED PLANS
06/27/2024 Permit Codes Residential Plan Review
07/11/2024 Permit DS Building Permit
07/11/2024 Receipt Receipt for transaction: 2024-005738
08/01/2024 Letter INSPECTION SUMMARY
08/01/2024 Letter INSPECTION SUMMARY
08/20/2024 Letter INSPECTION SUMMARY
08/20/2024 Letter INSPECTION SUMMARY
08/21/2024 Letter INSPECTION SUMMARY
08/21/2024 Letter INSPECTION SUMMARY
08/22/2024 Letter INSPECTION SUMMARY
09/03/2024 Letter INSPECTION SUMMARY
09/26/2024 3RD Party Insp Report THIRD PARTY SUSPENDED GARAGE INSPECTION
09/26/2024 Approved Plans 9-26-24 APPROVED PLAN
09/30/2024 Letter INSPECTION SUMMARY
09/30/2024 Letter INSPECTION SUMMARY
10/02/2024 Letter INSPECTION SUMMARY
10/04/2024 CORRECTED THIRD PARTY SUSPENDED GARAGE INSPECTION
10/04/2024 Letter INSPECTION SUMMARY
10/04/2024 Letter INSPECTION SUMMARY
11/08/2024 Letter INSPECTION SUMMARY
11/08/2024 Letter INSPECTION SUMMARY
11/08/2024 Letter INSPECTION SUMMARY
11/08/2024 Letter INSPECTION SUMMARY
11/08/2024 Letter INSPECTION SUMMARY
11/12/2024 Letter INSPECTION SUMMARY
12/02/2024 Letter INSPECTION SUMMARY
03/03/2025 Letter INSPECTION SUMMARY
03/11/2025 Letter INSPECTION SUMMARY
03/11/2025 Letter INSPECTION SUMMARY
04/29/2025 Letter INSPECTION SUMMARY
05/06/2025 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home