Permit Application Status

PRRES20233616


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20233616
Building Permit - Residential
Certificate of Occupancy
NEW DUPLEX
NEW DUPLEX. UNFINISHED BASEMENT. COVERED DECK AND COVERED PATIO. ROOF TRUSSES.
07/26/2023
08/04/2023
06/11/2024
06/17/2024
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
CARUTHERS ELECTRICAL LLC, Address:30905 E TRUMAN RD, Phone:(816) 508-9050  
BILL'S PLUMBING SERVICE LLC, Address:308 E PARK STREET, Phone:(913) 829-8213  
JASONH@CLOVERANDHIVE.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee for New Duplex $2,479.23 $2,479.23 Paid 08/04/2023
Water Tap Fee $7,520.00 $7,520.00 Paid 08/04/2023
Water Meter Fee $1,360.92 $1,360.92 Paid 08/04/2023
Sanitary Sewer Development Fee $4,318.00 $4,318.00 Paid 08/04/2023
Right of Way Permit Fee $85.00 $85.00 Paid 08/04/2023
Residential Excise Tax Fee $1,240.32 $1,240.32 Paid 08/04/2023
Not Ready Inspection Fee $75.00 $75.00 Paid 10/23/2023
Not Ready Inspection Fee $75.00 $75.00 Paid 10/23/2023
Not Ready Inspection Fee $75.00 $75.00 Paid 10/23/2023
Not Ready Inspection Fee $75.00 $75.00 Paid 01/02/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 02/05/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 03/07/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 06/11/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 06/11/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 8/16/2023 08/16/2023
Miscellaneous Correction
Informational
08/16/2023
Footing inspection was completed by a third party. Piers were not completed at the time of the footing inspection
Erosion Control Inspection Residential Failed 8/16/2023 08/16/2023
Miscellaneous Correction
Corrective Action Required
08/16/2023
Full erosion control is not installed. Full erosion control is required until occupancy of the building 08/16/2023. KBEARD
Sewer Service Inspection - R Passed 8/24/2023 (11:30) 8/24/2023 08/24/2023
Underslab Plumbing Inspection - Residential Passed 8/25/2023 8/25/2023 08/25/2023
Water Service Inspection - R Passed 8/25/2023 08/25/2023
Erosion Control Inspection Residential Failed 8/29/2023 08/29/2023
Miscellaneous Correction
Corrective Action Required
08/16/2023
Full erosion control is not installed. Full erosion control is required until occupancy of the building 08/16/2023. KBEARD
Miscellaneous Correction
Corrective Action Required
08/29/2023
Erosion control is missing, torn down or not installed. Full property erosion control must be maintained until full CO. Install erosion control, remove dirt and gravel in street. No inspections will be completed until proper erosion control is in place. 08/29/2023 KBEARD
All Rough Inspection - Residential Failed 9/28/2023 9/28/2023 09/28/2023
Miscellaneous Correction
Corrective Action Required
09/28/2023
This is a portal frame inspection only. 2204 Exterior NW corner single CS-PF portal frame is not nailed off. 2202 Passed
Erosion Control Inspection Residential Partial 10/3/2023 10/03/2023
Miscellaneous Correction
Corrective Action Required
08/29/2023
Full erosion control is not installed. Full erosion control is required until occupancy of the building 08/16/2023. KBEARD
Miscellaneous Correction
Resolved
10/03/2023
Erosion control is missing, torn down or not installed. Full property erosion control must be maintained until full CO. Install erosion control, remove dirt and gravel in street. No inspections will be completed until proper erosion control is in place. 08/29/2023 KBEARD
Miscellaneous Correction
Informational
10/03/2023
Erosion control is in place and needs to be maintained until full occupancy
All Rough Inspection - Residential Not Ready 10/13/2023 10/13/2023 10/13/2023
Miscellaneous Correction
Corrective Action Required
09/28/2023
This is a portal frame inspection only. 2204 Exterior NW corner single CS-PF portal frame is not nailed off. 2202 Passed
Miscellaneous Correction
Corrective Action Required
10/13/2023
Electrician was still working in both units in the basement. Insulation crew was working in 2202. 10/13/2023 KBEARD 9:30am
Erosion Control Inspection Residential Failed 10/16/2023 10/16/2023
Miscellaneous Correction
Resolved
10/16/2023
Full erosion control is not installed. Full erosion control is required until occupancy of the building 08/16/2023. KBEARD
Miscellaneous Correction
Informational
10/03/2023
Erosion control is in place and needs to be maintained until full occupancy
Miscellaneous Correction
Corrective Action Required
10/16/2023
Erosion control at the street has been damaged or is missing and needs to be replaced. Full erosion control must be maintained until C of O
All Rough Inspection - Residential Not Ready 10/16/2023 10/16/2023 10/16/2023
Miscellaneous Correction
Corrective Action Required
10/13/2023
This is a portal frame inspection only. 2204 Exterior NW corner single CS-PF portal frame is not nailed off. 2202 Passed
Miscellaneous Correction
Corrective Action Required
10/13/2023
Electrician was still working in both units in the basement. Insulation crew was working in 2202. 10/13/2023 KBEARD 9:30am
Miscellaneous Correction
Corrective Action Required
10/16/2023
-Plumbing is not completed in unit 2202 (missing bath tub up stairs and it’s drain hook up) -garage insulation needs to be removed in unit 2202 for inspection -Property needs to be walked before calling in for inspections Not ready for inspection 10/16/2023 KBEARD
All Rough Inspection - Residential Failed 10/17/2023 10/17/2023 10/17/2023
Miscellaneous Correction
Resolved
10/17/2023
This is a portal frame inspection only. 2204 Exterior NW corner single CS-PF portal frame is not nailed off. 2202 Passed
Miscellaneous Correction
Resolved
10/17/2023
Electrician was still working in both units in the basement. Insulation crew was working in 2202. 10/13/2023 KBEARD 9:30am
Miscellaneous Correction
Corrective Action Required
10/16/2023
-Plumbing is not completed in unit 2202 (missing bath tub up stairs and it’s drain hook up) -garage insulation needs to be removed in unit 2202 for inspection -Property needs to be walked before calling in for inspections Not ready for inspection 10/16/2023 KBEARD
Miscellaneous Correction
Corrective Action Required
10/17/2023
2204 Electrical wires can not obstruct access to attic access in garage Anchor bolts in garage need to be in the middle 1/3 sole plate Provide load bearing point for truss in garage and provide tie downs afterwards Nail double truss in great room 16 inches on center Address broken truss above bedroom 1 Entry west wall has two holes in the sole plate that needs to be sealed Entry west wall has electrical wire going through the plywood to the second story that needs to be sealed Seal 2 inch hole in kitchen floor All plumbing lines within 1 1/4 of wall edge needs to have a BOCA plate installed to extend not less than 2 inches up or down past the sole or top plate for protection (P2603.2.1) Seal HVAC chase in bathroom 2 at ceiling better after installation of 3/4 inch plywood Provide electrical within 6 feet of attic access Two joist hangers are missing in bedroom 3 HVAC in bedroom 3 needs to be hung from the top to allow proper installation according to approved plans Through penetrations in basement party wall needs to be sealed Provide documentation for sealant used in party wall for electrical service line 2 inch round hole in kitchen area floor needs to be sealed for fire blocking Provide engineers recommendation and replacement or repair for over bored and split ceiling joist 8-9 over from the HVAC Rated assembly decking has a large square hole cut in it for a roof vent Garage attic is not vented Electrical disconnect panel inside needs to have paint removed at the grounding point for proper grounding current 2202 LIB’s in garage are missing Hole in chase behind pantry needs to be fire blocked Fire blocking in garage around plumbing needs to be sealed better (2 areas) Rated assembly decking above utility room has a large square hole cut in it for venting Fire blocking in top plate located in the utility room is missing Kitchen floor has a hole in it LIB in bathroom of bedroom 1 is missing nails LIB in bedroom 1 is missing nails Joist hangers are not installed in great room and bedroom 1 like unit 2204 HVAC above bedroom 3 needs to be hung from above to allow proper installation according to plans Bathroom 2 HVAC chase can not be fire blocked using 1/2 inch plywood and new to be sealed better Drain holes under tub in bathroom 2 has a large gap and needs to be fire blocked Electrical around attic access hatch up stairs needs to be protected within 6 feet of opening Bathroom 2 vent above to roof needs to be supported every 4 feet on center Provide manufacturer recommendations for repairs for multiple gang plates that are damaged above kitchen and dining room Provide manufacturer recommendations for broken top cords above bed/bath 1 Fire block electrical service line through party wall Fire block ground wire through party wall Gas line needs to be supported to the wall in basement Double joist hanger is missing in basement by HVAC unit Provide engineers recommend repair or replacement for basement ceiling joist that have been over bored two over from the HVAC system and bathroom drain line about 10 feet from the HVAC system Garage attic space is not vented Provide load bearing point for truss in garage and proper tie downs for trusses afterwards Electrical disconnect inside panel needs paint to be removed at grounding points THIS IS NOT A COMPLETE LIST, Sheetrock in garage along west wall needs to be removed for inspection behind it Plans are left in garage of unit 2204
Gas Service Inspection - Residential Passed 10/17/2023 10/17/2023 10/17/2023
All Rough Inspection - Residential Not Ready 10/20/2023 10/20/2023 10/20/2023
Miscellaneous Correction
Corrective Action Required
10/17/2023
-Plumbing is not completed in unit 2202 (missing bath tub up stairs and it’s drain hook up) -garage insulation needs to be removed in unit 2202 for inspection -Property needs to be walked before calling in for inspections Not ready for inspection 10/16/2023 KBEARD
Miscellaneous Correction
Corrective Action Required
10/17/2023
2204 Electrical wires can not obstruct access to attic access in garage Anchor bolts in garage need to be in the middle 1/3 sole plate Provide load bearing point for truss in garage and provide tie downs afterwards Nail double truss in great room 16 inches on center Address broken truss above bedroom 1 Entry west wall has two holes in the sole plate that needs to be sealed Entry west wall has electrical wire going through the plywood to the second story that needs to be sealed Seal 2 inch hole in kitchen floor All plumbing lines within 1 1/4 of wall edge needs to have a BOCA plate installed to extend not less than 2 inches up or down past the sole or top plate for protection (P2603.2.1) Seal HVAC chase in bathroom 2 at ceiling better after installation of 3/4 inch plywood Provide electrical within 6 feet of attic access Two joist hangers are missing in bedroom 3 HVAC in bedroom 3 needs to be hung from the top to allow proper installation according to approved plans Through penetrations in basement party wall needs to be sealed Provide documentation for sealant used in party wall for electrical service line 2 inch round hole in kitchen area floor needs to be sealed for fire blocking Provide engineers recommendation and replacement or repair for over bored and split ceiling joist 8-9 over from the HVAC Rated assembly decking has a large square hole cut in it for a roof vent Garage attic is not vented Electrical disconnect panel inside needs to have paint removed at the grounding point for proper grounding current 2202 LIB’s in garage are missing Hole in chase behind pantry needs to be fire blocked Fire blocking in garage around plumbing needs to be sealed better (2 areas) Rated assembly decking above utility room has a large square hole cut in it for venting Fire blocking in top plate located in the utility room is missing Kitchen floor has a hole in it LIB in bathroom of bedroom 1 is missing nails LIB in bedroom 1 is missing nails Joist hangers are not installed in great room and bedroom 1 like unit 2204 HVAC above bedroom 3 needs to be hung from above to allow proper installation according to plans Bathroom 2 HVAC chase can not be fire blocked using 1/2 inch plywood and new to be sealed better Drain holes under tub in bathroom 2 has a large gap and needs to be fire blocked Electrical around attic access hatch up stairs needs to be protected within 6 feet of opening Bathroom 2 vent above to roof needs to be supported every 4 feet on center Provide manufacturer recommendations for repairs for multiple gang plates that are damaged above kitchen and dining room Provide manufacturer recommendations for broken top cords above bed/bath 1 Fire block electrical service line through party wall Fire block ground wire through party wall Gas line needs to be supported to the wall in basement Double joist hanger is missing in basement by HVAC unit Provide engineers recommend repair or replacement for basement ceiling joist that have been over bored two over from the HVAC system and bathroom drain line about 10 feet from the HVAC system Garage attic space is not vented Provide load bearing point for truss in garage and proper tie downs for trusses afterwards Electrical disconnect inside panel needs paint to be removed at grounding points THIS IS NOT A COMPLETE LIST, Sheetrock in garage along west wall needs to be removed for inspection behind it Plans are left in garage of unit 2204
Miscellaneous Correction
Corrective Action Required
10/20/2023
2202 and 2204 2204 Electrical wires can not obstruct access to attic access in garage Anchor bolts in garage need to be in the middle 1/3 sole plate Provide load bearing point for truss in garage and provide tie downs afterwards Nail double truss in great room 16 inches on center Address broken truss above bedroom 1 Entry west wall has two holes in the sole plate that needs to be sealed Entry west wall has electrical wire going through the plywood to the second story that needs to be sealed Seal 2 inch hole in kitchen floor All plumbing lines within 1 1/4 of wall edge needs to have a BOCA plate installed to extend not less than 2 inches up or down past the sole or top plate for protection (P2603.2.1) Seal HVAC chase in bathroom 2 at ceiling better after installation of 3/4 inch plywood Provide electrical protection within 6 feet of attic access Two joist hangers are missing in bedroom 3 HVAC in bedroom 3 needs to be hung from the top to allow proper installation according to approved plans Through penetrations in basement party wall needs to be sealed Provide documentation for sealant used in party wall for electrical service line 2 inch round hole in kitchen area floor needs to be sealed for fire blocking Provide engineers recommendation and replacement or repair for over bored and split ceiling joist 8-9 over from the HVAC Rated assembly decking has a large square hole cut in it for a roof vent Garage attic is not vented Electrical disconnect panel inside needs to have paint removed at the grounding point for proper grounding current THIS IS NOT A COMPLETE LIST 2202 LIB’s in garage are missing Hole in chase behind pantry needs to be fire blocked Fire blocking in garage around plumbing needs to be sealed better (2 areas) Rated assembly decking above utility room has a large square hole cut in it for venting Fire blocking in top plate located in the utility room is missing Kitchen floor has a hole in it LIB in bathroom of bedroom 1 is missing nails LIB in bedroom 1 is missing nails Joist hangers are not installed in great room and bedroom 1 like unit 2204 HVAC above bedroom 3 needs to be hung from above to allow proper installation according to plans Bathroom 2 HVAC chase can not be fire blocked using 1/2 inch plywood and new to be sealed better Drain holes under tub in bathroom 2 has a large gap and needs to be fire blocked Electrical around attic access hatch up stairs needs to be protected within 6 feet of opening Bathroom 2 vent above to roof needs to be supported every 4 feet on center Provide manufacturer recommendations for repairs for multiple gang plates that are damaged above kitchen and dining room Provide manufacturer recommendations for broken top cords above bed/bath 1 Fire block electrical service line through party wall Fire block ground wire through party wall Gas line needs to be supported to the wall in basement Double joist hanger is missing in basement by HVAC unit Provide engineers recommend repair or replacement for basement ceiling joist that have been over bored two over from the HVAC system and bathroom drain line about 10 feet from the HVAC system Garage attic space is not vented Provide load bearing point for truss in garage and proper tie downs for trusses afterwards Electrical disconnect inside panel needs paint to be removed at grounding points THIS IS NOT A COMPLETE LIST Most of this list has not been completed. Duplex has been insulated and some inspections can not be completed. Engineer letters have not been uploaded to the cities portal. Electrician is working in both sides of duplex. Duplex is NOT READY for re inspection 10/20/2023 KBEARD 9:55AM
Rated Assembly Inspection Partial 10/23/2023 10/23/2023 10/23/2023
Miscellaneous Correction
Corrective Action Required
10/23/2023
Party wall rated assembly passed. Both units need to have the garage fire rated sheet rock and screw pattern inspected before covering. This is a partial pass only
All Rough Inspection - Residential Passed 10/25/2023 10/25/2023 10/25/2023
Miscellaneous Correction
Resolved
10/25/2023
-Plumbing is not completed in unit 2202 (missing bath tub up stairs and it’s drain hook up) -garage insulation needs to be removed in unit 2202 for inspection -Property needs to be walked before calling in for inspections Not ready for inspection 10/16/2023 KBEARD
Miscellaneous Correction
Resolved
10/25/2023
2204 Electrical wires can not obstruct access to attic access in garage Anchor bolts in garage need to be in the middle 1/3 sole plate Provide load bearing point for truss in garage and provide tie downs afterwards Nail double truss in great room 16 inches on center Address broken truss above bedroom 1 Entry west wall has two holes in the sole plate that needs to be sealed Entry west wall has electrical wire going through the plywood to the second story that needs to be sealed Seal 2 inch hole in kitchen floor All plumbing lines within 1 1/4 of wall edge needs to have a BOCA plate installed to extend not less than 2 inches up or down past the sole or top plate for protection (P2603.2.1) Seal HVAC chase in bathroom 2 at ceiling better after installation of 3/4 inch plywood Provide electrical within 6 feet of attic access Two joist hangers are missing in bedroom 3 HVAC in bedroom 3 needs to be hung from the top to allow proper installation according to approved plans Through penetrations in basement party wall needs to be sealed Provide documentation for sealant used in party wall for electrical service line 2 inch round hole in kitchen area floor needs to be sealed for fire blocking Provide engineers recommendation and replacement or repair for over bored and split ceiling joist 8-9 over from the HVAC Rated assembly decking has a large square hole cut in it for a roof vent Garage attic is not vented Electrical disconnect panel inside needs to have paint removed at the grounding point for proper grounding current 2202 LIB’s in garage are missing Hole in chase behind pantry needs to be fire blocked Fire blocking in garage around plumbing needs to be sealed better (2 areas) Rated assembly decking above utility room has a large square hole cut in it for venting Fire blocking in top plate located in the utility room is missing Kitchen floor has a hole in it LIB in bathroom of bedroom 1 is missing nails LIB in bedroom 1 is missing nails Joist hangers are not installed in great room and bedroom 1 like unit 2204 HVAC above bedroom 3 needs to be hung from above to allow proper installation according to plans Bathroom 2 HVAC chase can not be fire blocked using 1/2 inch plywood and new to be sealed better Drain holes under tub in bathroom 2 has a large gap and needs to be fire blocked Electrical around attic access hatch up stairs needs to be protected within 6 feet of opening Bathroom 2 vent above to roof needs to be supported every 4 feet on center Provide manufacturer recommendations for repairs for multiple gang plates that are damaged above kitchen and dining room Provide manufacturer recommendations for broken top cords above bed/bath 1 Fire block electrical service line through party wall Fire block ground wire through party wall Gas line needs to be supported to the wall in basement Double joist hanger is missing in basement by HVAC unit Provide engineers recommend repair or replacement for basement ceiling joist that have been over bored two over from the HVAC system and bathroom drain line about 10 feet from the HVAC system Garage attic space is not vented Provide load bearing point for truss in garage and proper tie downs for trusses afterwards Electrical disconnect inside panel needs paint to be removed at grounding points THIS IS NOT A COMPLETE LIST, Sheetrock in garage along west wall needs to be removed for inspection behind it Plans are left in garage of unit 2204
Miscellaneous Correction
Resolved
10/25/2023
2202 and 2204 2204 Electrical wires can not obstruct access to attic access in garage Anchor bolts in garage need to be in the middle 1/3 sole plate Provide load bearing point for truss in garage and provide tie downs afterwards Nail double truss in great room 16 inches on center Address broken truss above bedroom 1 Entry west wall has two holes in the sole plate that needs to be sealed Entry west wall has electrical wire going through the plywood to the second story that needs to be sealed Seal 2 inch hole in kitchen floor All plumbing lines within 1 1/4 of wall edge needs to have a BOCA plate installed to extend not less than 2 inches up or down past the sole or top plate for protection (P2603.2.1) Seal HVAC chase in bathroom 2 at ceiling better after installation of 3/4 inch plywood Provide electrical protection within 6 feet of attic access Two joist hangers are missing in bedroom 3 HVAC in bedroom 3 needs to be hung from the top to allow proper installation according to approved plans Through penetrations in basement party wall needs to be sealed Provide documentation for sealant used in party wall for electrical service line 2 inch round hole in kitchen area floor needs to be sealed for fire blocking Provide engineers recommendation and replacement or repair for over bored and split ceiling joist 8-9 over from the HVAC Rated assembly decking has a large square hole cut in it for a roof vent Garage attic is not vented Electrical disconnect panel inside needs to have paint removed at the grounding point for proper grounding current THIS IS NOT A COMPLETE LIST 2202 LIB’s in garage are missing Hole in chase behind pantry needs to be fire blocked Fire blocking in garage around plumbing needs to be sealed better (2 areas) Rated assembly decking above utility room has a large square hole cut in it for venting Fire blocking in top plate located in the utility room is missing Kitchen floor has a hole in it LIB in bathroom of bedroom 1 is missing nails LIB in bedroom 1 is missing nails Joist hangers are not installed in great room and bedroom 1 like unit 2204 HVAC above bedroom 3 needs to be hung from above to allow proper installation according to plans Bathroom 2 HVAC chase can not be fire blocked using 1/2 inch plywood and new to be sealed better Drain holes under tub in bathroom 2 has a large gap and needs to be fire blocked Electrical around attic access hatch up stairs needs to be protected within 6 feet of opening Bathroom 2 vent above to roof needs to be supported every 4 feet on center Provide manufacturer recommendations for repairs for multiple gang plates that are damaged above kitchen and dining room Provide manufacturer recommendations for broken top cords above bed/bath 1 Fire block electrical service line through party wall Fire block ground wire through party wall Gas line needs to be supported to the wall in basement Double joist hanger is missing in basement by HVAC unit Provide engineers recommend repair or replacement for basement ceiling joist that have been over bored two over from the HVAC system and bathroom drain line about 10 feet from the HVAC system Garage attic space is not vented Provide load bearing point for truss in garage and proper tie downs for trusses afterwards Electrical disconnect inside panel needs paint to be removed at grounding points THIS IS NOT A COMPLETE LIST Most of this list has not been completed. Duplex has been insulated and some inspections can not be completed. Engineer letters have not been uploaded to the cities portal. Electrician is working in both sides of duplex. Duplex is NOT READY for re inspection 10/20/2023 KBEARD 9:55AM
Electrical Service Inspection Passed 10/25/2023 10/25/2023 10/25/2023
Rated Assembly Inspection Passed 10/25/2023 10/25/2023 10/25/2023
Miscellaneous Correction
Resolved
10/25/2023
Party wall rated assembly passed. Both units need to have the garage fire rated sheet rock and screw pattern inspected before covering. This is a partial pass only
Driveway Inspection Partial 11/27/2023 11/27/2023 11/27/2023
Misc
Informational
11/27/2023
11-27-23 Dustin A, DW is formed and aggregate is compacted. Will need to maintain ada compliance through approach. Approved to pour
Sidewalk Inspection Partial 11/27/2023 11/27/2023 11/27/2023
Misc
Informational
11/27/2023
11-27-23 Dustin A, SW is formed. Aggregate is compacted . Slopes are in compliance. Approved to pour.
Piers/Caissons Inspection - Residential Passed 11/30/2023 11/30/2023
Miscellaneous Correction
Informational
11/30/2023
Two deck piers were inspected at 2202 SW Osage for a rear deck without stairs
Piers/Caissons Inspection - Residential Passed 11/30/2023 (1:00) 11/30/2023 11/30/2023
Miscellaneous Correction
Informational
11/30/2023
Two deck piers at 2202 passed. There are no stairs on the back deck
Driveway Inspection Passed 12/4/2023 12/4/2023 12/04/2023
Misc
Informational
11/27/2023
11-27-23 Dustin A, DW is formed and aggregate is compacted. Will need to maintain ada compliance through approach. Approved to pour 12-4-23 Dustin A, Dw Is poured, Slopes are in compliance forms are pulled. Passed.
Sidewalk Inspection Passed 12/04/2023
Misc
Informational
11/27/2023
11-27-23 Dustin A, SW is formed. Aggregate is compacted . Slopes are in compliance. Approved to pour. 12-4-23 Dustin A, Sw is poured and forms are pulled. Slopes are in compliance . Passed
Occupancy Inspection - Codes Residential Failed 12/13/2023 12/13/2023 12/13/2023
Misc
Corrective Action Required
12/13/2023
-Missing handrail at garages stairs -Adjust self closing hinges at garage stairs -Missing center bracket at hand rail going upstairs -Break off tamper proof screw at anti siphon device in basement
Occupancy Inspection - Codes Residential Not Ready 12/18/2023 12/18/2023 12/18/2023
Misc
Corrective Action Required
12/13/2023
-Missing handrail at garages stairs -Adjust self closing hinges at garage stairs -Missing center bracket at hand rail going upstairs -Break off tamper proof screw at anti siphon device in basement
Occupancy Inspection - Codes Residential Failed 12/21/2023 12/21/2023 12/21/2023
Misc
Partial Correction
12/21/2023
-Missing handrail at garages stairs -Adjust self closing hinges at garage stairs -Missing center bracket at hand rail going upstairs -Break off tamper proof screw at anti siphon device in basement
Miscellaneous Correction
Corrective Action Required
12/21/2023
2204 -Missing handrail at garages stairs -Adjust self closing hinges at garage stairs -Missing center bracket at hand rail going upstairs -Break off tamper proof screw at anti siphon device in basement -exterior was not ready for inspection 2202 -Exterior of unit was not ready for inspection 2202 passed for TCO only
Occupancy Inspection - Codes Residential Failed 1/5/2024 1/5/2024 01/05/2024
Misc
Partial Correction
12/21/2023
-Missing handrail at garages stairs -Adjust self closing hinges at garage stairs -Missing center bracket at hand rail going upstairs -Break off tamper proof screw at anti siphon device in basement
Miscellaneous Correction
Corrective Action Required
12/21/2023
2204 -Missing handrail at garages stairs -Adjust self closing hinges at garage stairs -Missing center bracket at hand rail going upstairs -Break off tamper proof screw at anti siphon device in basement -exterior was not ready for inspection 2202 -Exterior of unit was not ready for inspection 2202 passed for TCO only
Misc
Corrective Action Required
01/05/2024
-No access
Occupancy Inspection - Codes Residential Ready for Temp CO 2/5/2024 2/5/2024 02/05/2024
Misc
Partial Correction
01/05/2024
-Missing handrail at garages stairs -Adjust self closing hinges at garage stairs -Missing center bracket at hand rail going upstairs -Break off tamper proof screw at anti siphon device in basement
Miscellaneous Correction
Resolved
02/05/2024
2204 -Missing handrail at garages stairs -Adjust self closing hinges at garage stairs -Missing center bracket at hand rail going upstairs -Break off tamper proof screw at anti siphon device in basement -exterior was not ready for inspection 2202 -Exterior of unit was not ready for inspection 2202 passed for TCO only
Misc
Resolved
02/05/2024
-No access
Miscellaneous Correction
Corrective Action Required
02/05/2024
- Sod and splash pads are not installed - Clean out debris from window well of unit 2204 Both properties passed for TCO only
Erosion Control Inspection Residential Partial 2/5/2024 02/05/2024
Miscellaneous Correction
Informational
10/16/2023
Erosion control is in place and needs to be maintained until full occupancy
Miscellaneous Correction
Resolved
02/05/2024
Erosion control at the street has been damaged or is missing and needs to be replaced. Full erosion control must be maintained until C of O
Miscellaneous Correction
Informational
02/05/2024
Erosion control is in place at the time of TCO Full erosion control must be maintained until CofO
Erosion Control Inspection Residential Partial 3/4/2024 03/04/2024
Miscellaneous Correction
Informational
02/05/2024
Erosion control is in place and needs to be maintained until full occupancy
Miscellaneous Correction
Informational
02/05/2024
Erosion control is in place at the time of TCO Full erosion control must be maintained until CofO
Miscellaneous Correction
Informational
03/04/2024
Erosion control is in place Full erosion control must be maintained until CofO
Occupancy Inspection - Codes Residential Failed 3/4/2024 03/04/2024
Misc
Partial Correction
02/05/2024
-Missing handrail at garages stairs -Adjust self closing hinges at garage stairs -Missing center bracket at hand rail going upstairs -Break off tamper proof screw at anti siphon device in basement
Miscellaneous Correction
Resolved
03/04/2024
- Sod and splash pads are not installed - Clean out debris from window well of unit 2204 Both properties passed for TCO only
Miscellaneous Correction
Corrective Action Required
03/04/2024
Sod and splash pads are still not installed TCO for both properties has already been issued If this is a TCO extension request, please fill out an extension request form. Full occupancy inspection is failed
Occupancy Inspection - Codes Residential Ready for Temp CO 3/6/2024 03/06/2024
Misc
Resolved
03/06/2024
-Missing handrail at garages stairs -Adjust self closing hinges at garage stairs -Missing center bracket at hand rail going upstairs -Break off tamper proof screw at anti siphon device in basement
Miscellaneous Correction
Resolved
03/06/2024
Sod and splash pads are still not installed TCO for both properties has already been issued If this is a TCO extension request, please fill out an extension request form. Full occupancy inspection is failed
Miscellaneous Correction
Corrective Action Required
03/06/2024
-Sod and splash pads are still not installed -TCO for both properties has already been issued TCO extension was requested and granted. This is the first extension request 03/06/24 KBEARD
Plot Plan Inspection Failed 4/9/2024 04/09/2024
Miscellaneous Correction
Corrective Action Required
04/09/2024
-Sod was installed prior to submitting as graded plot plan. -As graded plot plan is required on the City approved plot plan
Occupancy Inspection - Codes Residential Not Ready 4/11/2024 04/11/2024
Miscellaneous Correction
Resolved
04/11/2024
-Sod and splash pads are still not installed -TCO for both properties has already been issued TCO extension was requested and granted. This is the first extension request 03/06/24 KBEARD
Miscellaneous Correction
Corrective Action Required
04/11/2024
-Plot plan must pass -Email was sent asking for a TCO extension form to be filled out. -No response from the email request -Not ready for TCO extension and fees added 04/11/2024 KBEARD
Plot Plan Inspection Passed 6/11/2024 06/11/2024
Miscellaneous Correction
Resolved
06/11/2024
-Sod was installed prior to submitting as graded plot plan. -As graded plot plan is required on the City approved plot plan
Erosion Control Inspection Residential Passed 6/11/2024 06/11/2024
Miscellaneous Correction
Resolved
06/11/2024
Erosion control is in place and needs to be maintained until full occupancy
Miscellaneous Correction
Resolved
06/11/2024
Erosion control is in place at the time of TCO Full erosion control must be maintained until CofO
Miscellaneous Correction
Resolved
06/11/2024
Erosion control is in place Full erosion control must be maintained until CofO
Occupancy Inspection - Codes Residential Full C of O 6/17/2024 06/17/2024
Miscellaneous Correction
Resolved
06/17/2024
-Plot plan must pass -Email was sent asking for a TCO extension form to be filled out. -No response from the email request -Not ready for TCO extension and fees added 04/11/2024 KBEARD
Documents & Images
Date Uploaded File Type Document Name
07/26/2023 OS #58 - PERMIT APP
07/28/2023 Permit Codes Residential Plan Review
07/31/2023 Plot Plan APPROVED PLOT PLAN
08/03/2023 Approved Plans APPROVED TRUSS LAYOUT
08/03/2023 Approved Plans APPROVED TRUSS PACKAGE
08/03/2023 Approved Plans APPROVED PLANS
08/03/2023 Permit Codes Residential Plan Review
08/04/2023 Permit DS Building Permit
08/04/2023 Receipt Receipt for transaction:2023-006051
08/15/2023 2202 & 2204 SW Osage Dr LSMO Osage Lot 58 Clayton Properties P 2023-3616 3rd Party Footing Inspection Report 8-15-23
08/16/2023 Letter INSPECTION SUMMARY
08/16/2023 Letter INSPECTION SUMMARY
08/24/2023 Letter INSPECTION SUMMARY
08/25/2023 Letter INSPECTION SUMMARY
08/25/2023 Letter INSPECTION SUMMARY
08/29/2023 Letter INSPECTION SUMMARY
09/28/2023 Letter INSPECTION SUMMARY
10/03/2023 Letter INSPECTION SUMMARY
10/13/2023 Letter INSPECTION SUMMARY
10/13/2023 ENG-Roof-Broken Chords or Missing Splice Plate
10/13/2023 I61356003_P220321-P220321-02
10/16/2023 Letter INSPECTION SUMMARY
10/16/2023 Letter INSPECTION SUMMARY
10/17/2023 Letter INSPECTION SUMMARY
10/17/2023 Letter INSPECTION SUMMARY
10/20/2023 Letter INSPECTION SUMMARY
10/23/2023 Receipt Receipt for transaction:2023-007943
10/23/2023 A 2204 SW Osage Dr - Field Issue Letter
10/23/2023 B 2202 SW Osage Dr - Field Issue Letter
10/23/2023 A 2204 SW Osage Dr - Notched FJ
10/23/2023 B 2202 SW Osage Dr - Notched FJ
10/23/2023 Letter INSPECTION SUMMARY
10/25/2023 Letter INSPECTION SUMMARY
10/25/2023 Letter INSPECTION SUMMARY
10/25/2023 Letter INSPECTION SUMMARY
10/26/2023 A 2204 SW Osage Dr - Garage Truss Hangers
10/26/2023 B 2202 SW Osage Dr - Garage Truss Hangers
11/27/2023 Letter INSPECTION SUMMARY
11/27/2023 Letter INSPECTION SUMMARY
11/30/2023 Letter INSPECTION SUMMARY
11/30/2023 Letter INSPECTION SUMMARY
12/04/2023 Letter INSPECTION SUMMARY
12/04/2023 Letter INSPECTION SUMMARY
12/13/2023 Letter INSPECTION SUMMARY
12/18/2023 Letter INSPECTION SUMMARY
12/21/2023 Letter INSPECTION SUMMARY
01/02/2024 Receipt Receipt for transaction:2024-000024
01/05/2024 Letter INSPECTION SUMMARY
02/05/2024 Letter INSPECTION SUMMARY
02/05/2024 Certificate/License Codes Temporary Certificate of Occupancy
02/05/2024 Receipt Receipt for transaction:2024-000607
02/26/2024 OS 58 - TCO Extension App
03/04/2024 Letter INSPECTION SUMMARY
03/04/2024 Letter INSPECTION SUMMARY
03/07/2024 Certificate/License Codes Temporary Certificate of Occupancy
03/07/2024 Receipt Receipt for transaction:2024-001414
04/09/2024 Letter INSPECTION SUMMARY
04/11/2024 Letter INSPECTION SUMMARY
06/10/2024 LOT 58 ASBUILT
06/10/2024 Plot Plan approved as graded plot plan
06/11/2024 Letter INSPECTION SUMMARY
06/11/2024 Letter INSPECTION SUMMARY
06/11/2024 Certificate/License Codes Temporary Certificate of Occupancy
06/11/2024 Certificate/License Codes Temporary Certificate of Occupancy
06/11/2024 Receipt Receipt for transaction:2024-004605
06/17/2024 Letter Field Certificate of Occupancy
06/17/2024 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home