Permit Application Status

PRRES20232719


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20232719
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - ROOF TRUSSES STOP WORK ORDER generated on 08/23/2023 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER removed on 11/17/2023 12:00 AM by username 'Mitchell Schwarz'.
06/12/2023
06/21/2023
12/10/2023
03/04/2024
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
CMH PARKS INC, Address:5000 CLAYTON RD  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Sanitary Sewer Development Fee $1,384.00 $1,384.00 Paid 06/21/2023
Right of Way Permit Fee $85.00 $85.00 Paid 06/21/2023
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 06/21/2023
Water Tap Fee $3,730.00 $3,730.00 Paid 06/21/2023
Water Meter Fee $550.50 $550.50 Paid 06/21/2023
Valuation Fee New Single Family $1,285.53 $1,285.53 Paid 06/21/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 6/30/2023 (9:30) 6/30/2023 06/30/2023
Misc
Informational
06/30/2023
Pier for covered patio poured with footing
Sewer Service Inspection - R Passed 7/17/2023 (1:30) 7/17/2023 07/17/2023
Water Service Inspection - R Partial 2/17/2024 07/17/2023
Misc
Informational
07/17/2023
Pex ran from foundation roughly 20’
Water Service Inspection - R Passed 7/19/2023 7/19/2023 07/19/2023
Misc
Resolved
07/19/2023
Pex ran from foundation roughly 20’
Underslab Plumbing Inspection - Residential Passed 7/20/2023 7/20/2023 07/20/2023
Erosion Control Inspection Residential Failed 11/15/2023 11/15/2023 08/18/2023
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
08/18/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -maintain downed silt fence -maintain gravel filter drive
Erosion Control Inspection Residential Failed - Stop Work 8/23/2023 8/23/2023 08/23/2023
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
08/18/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -maintain downed silt fence -maintain gravel filter drive
Misc
Corrective Action Required
08/23/2023
Erosion control still not in compliance. Stop work issued. Mitchell Schwarz 8/23/23 1:18PM
Erosion Control Inspection Residential Failed 11/6/2023 11/6/2023 11/06/2023
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
08/23/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -maintain downed silt fence -maintain gravel filter drive
Misc
Resolved
11/06/2023
Erosion control still not in compliance. Stop work issued. Mitchell Schwarz 8/23/23 1:18PM Gravel filter, still not in compliance. Mitchell Schwarz 11/05/23 10:25Am
Erosion Control Inspection Residential Partial 11/17/2023 11/17/2023 11/17/2023
DCM3 ESC REQUIRED 2 DAY
Resolved
11/17/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -maintain downed silt fence -maintain gravel filter drive
Misc
Informational
11/17/2023
Erosion control in compliance at time of inspection.
Gas Service Inspection - Residential Failed 11/20/2023 11/20/2023 11/20/2023
Miscellaneous Correction
Corrective Action Required
11/20/2023
Gas line is not grounded
Electrical Service Inspection Passed 11/20/2023 11/20/2023 11/20/2023
All Rough Inspection - Residential Failed 11/20/2023 11/20/2023 11/20/2023
Miscellaneous Correction
Corrective Action Required
11/20/2023
1532 hawthorn Third car garage is missing a 5/8 inch anchor bolt with a 3x3 plate and nut Double garage door sole plate has been over notched at anchor bolt LIB in bedroom 2 is missing nails Plumbing vent line at sole plate by refrigerator needs the BOCA moved to cover past both lines horizontally Truss tie down straps in great room by fireplace are all missing two nails at the top Water lines in the basement linen closet are not supported in the ceiling Top plate Fire blocking is needed in basement bedroom 3 above entry door Secure gas line in basement at rec room going up to the great room Front and back porch truss tie downs could not be verified because of soffit already installed Garage portal framing inspection could be be fully verified due to siding
All Rough Inspection - Residential Failed 11/28/2023 11/28/2023 11/28/2023
Miscellaneous Correction
Resolved
11/28/2023
1532 hawthorn Third car garage is missing a 5/8 inch anchor bolt with a 3x3 plate and nut Double garage door sole plate has been over notched at anchor bolt LIB in bedroom 2 is missing nails Plumbing vent line at sole plate by refrigerator needs the BOCA moved to cover past both lines horizontally Truss tie down straps in great room by fireplace are all missing two nails at the top Water lines in the basement linen closet are not supported in the ceiling Top plate Fire blocking is needed in basement bedroom 3 above entry door Secure gas line in basement at rec room going up to the great room Front and back porch truss tie downs could not be verified because of soffit already installed Garage portal framing inspection could be be fully verified due to siding
Miscellaneous Correction
Corrective Action Required
11/28/2023
LIB in bedroom 2 is missing nails Truss tie down straps in great room by fireplace are all missing two nails at the top Truss tie down can be bent over the bottom truss cord and nailed down utilizing the complete truss bracket
Gas Service Inspection - Residential Passed 11/28/2023 11/28/2023 11/28/2023
Miscellaneous Correction
Resolved
11/28/2023
Gas line is not grounded
All Rough Inspection - Residential Passed 11/29/2023 11/29/2023 11/29/2023
Miscellaneous Correction
Resolved
11/29/2023
LIB in bedroom 2 is missing nails Truss tie down straps in great room by fireplace are all missing two nails at the top Truss tie down can be bent over the bottom truss cord and nailed down utilizing the complete truss bracket
Sidewalk Inspection Partial 12/14/2023 12/14/2023
Misc
Informational
12/14/2023
12-14-23 Dustin A. SW is formed and aggregate is compacted. Slopes are in compliance approved to pour. Will need white cure applied
Driveway Inspection Partial 12/14/2023 12/14/2023
Misc
Informational
12/14/2023
12-14-23 Dustin A. dw is formed. aggregate is compacted . and depth is in compliance. Will need to maintain ADA specs through approach. Approved to pour
Sidewalk Inspection Partial 12/19/2023 12/19/2023 12/18/2023
Misc
Informational
12/14/2023
12-14-23 Dustin A. SW is formed and aggregate is compacted. Slopes are in compliance approved to pour. Will need white cure applied 12-18-23 Dustin A, blankets still on , will come back in week
Driveway Inspection Partial 12/19/2023 12/19/2023 12/18/2023
Misc
Informational
12/14/2023
12-14-23 Dustin A. dw is formed. aggregate is compacted . and depth is in compliance. Will need to maintain ADA specs through approach. Approved to pour 12-18-23 Dustin A, blankets still oc, will come back in a week
Driveway Inspection Failed 12/27/2023 12/27/2023 12/27/2023
Misc
Informational
12/18/2023
12-14-23 Dustin A. dw is formed. aggregate is compacted . and depth is in compliance. Will need to maintain ADA specs through approach. Approved to pour 12-18-23 Dustin A, blankets still oc, will come back in a week 12-27-23 Dustin A, dw is poured, slopes are in compliance. left panel is cracked. Fail
Sidewalk Inspection Partial 12/27/2023 12/27/2023 12/27/2023
Misc
Informational
12/18/2023
12-14-23 Dustin A. SW is formed and aggregate is compacted. Slopes are in compliance approved to pour. Will need white cure applied 12-18-23 Dustin A, blankets still on , will come back in week 12-27-23 Dustin A, conditions have not changed
Sidewalk Inspection Partial 1/5/2024 1/5/2024 01/05/2024
Misc
Informational
12/27/2023
12-14-23 Dustin A. SW is formed and aggregate is compacted. Slopes are in compliance approved to pour. Will need white cure applied 12-18-23 Dustin A, blankets still on , will come back in week 12-27-23 Dustin A, conditions have not changed 1-5-24 Dustin A, Blankets removed. White cure has been put on incorrect. Will need to be fixed
Sidewalk Inspection Passed 1/30/2024 1/30/2024 01/25/2024
Misc
Informational
01/05/2024
12-14-23 Dustin A. SW is formed and aggregate is compacted. Slopes are in compliance approved to pour. Will need white cure applied 12-18-23 Dustin A, blankets still on , will come back in week 12-27-23 Dustin A, conditions have not changed 1-5-24 Dustin A, Blankets removed. White cure has been put on incorrect. Will need to be fixed 1-25-24 Dustin A, After review with RH cure will pass
Erosion Control Inspection Residential Failed 2/7/2024 02/07/2024
Misc
Resolved
02/07/2024
Erosion control in compliance at time of inspection.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
02/07/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/07/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. NO EROSION CONTROL INSTALLED
Occupancy Inspection - Codes Residential Failed 2/28/2024 2/28/2024 02/28/2024
Misc
Corrective Action Required
02/28/2024
-provide as graded plot plan -address pending driveway inspection -guard rail required at front stoop over 30” from garage 36” out -egress window well ladder maximum 18” step spacing.
Plot Plan Inspection Passed 2/29/2024 02/29/2024
Erosion Control Inspection Residential Passed 3/1/2024 03/01/2024
DCM3 ESC REQUIRED 2 DAY
Resolved
03/01/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM2 ESC DEFICIENT INSTALLATION
Resolved
03/01/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. NO EROSION CONTROL INSTALLED
Occupancy Inspection - Codes Residential Failed 3/1/2024 3/1/2024 03/01/2024
Misc
Corrective Action Required
02/28/2024
-address pending driveway inspection
Driveway Inspection Passed 3/1/2024 3/1/2024 03/01/2024
Misc
Informational
12/27/2023
12-14-23 Dustin A. dw is formed. aggregate is compacted . and depth is in compliance. Will need to maintain ADA specs through approach. Approved to pour 12-18-23 Dustin A, blankets still oc, will come back in a week 12-27-23 Dustin A, dw is poured, slopes are in compliance. left panel is cracked. Fail 3-1-24 Dustin A, Dw panel has been replaced. Passed
Occupancy Inspection - Codes Residential Full C of O 3/4/2024 3/4/2024 03/04/2024
Misc
Resolved
03/04/2024
-address pending driveway inspection
Documents & Images
Date Uploaded File Type Document Name
06/12/2023 H3 #76 - Cypress - Craftsman - Sheets- signed
06/12/2023 76 HAWTHORNE RIDGE ROOF LAYOUT
06/12/2023 LOT 76 FINAL
06/12/2023 I50414024_B220036
06/12/2023 H3 #76 - PERMIT APP
06/13/2023 Approved Plans APPROVED PLANS
06/13/2023 Approved Plans APPROVED TRUSS LAYOUT
06/13/2023 Approved Plans APPROVED TRUSS PACKAGE
06/13/2023 Permit Codes Residential Plan Review
06/19/2023 LOT 76 CITY
06/20/2023 Permit Codes Residential Plan Review
06/20/2023 Plot Plan approved plot plan
06/21/2023 Permit DS Building Permit
06/21/2023 Receipt Receipt for transaction:2023-004668
06/30/2023 Letter INSPECTION SUMMARY
06/30/2023 Letter INSPECTION SUMMARY
07/17/2023 Letter INSPECTION SUMMARY
07/17/2023 Letter INSPECTION SUMMARY
07/19/2023 Letter INSPECTION SUMMARY
07/20/2023 Letter INSPECTION SUMMARY
08/18/2023 Letter INSPECTION SUMMARY
08/23/2023 Letter Stop Work Order
11/06/2023 Letter INSPECTION SUMMARY
11/17/2023 Letter INSPECTION SUMMARY
11/20/2023 Letter INSPECTION SUMMARY
11/20/2023 Letter INSPECTION SUMMARY
11/20/2023 Letter INSPECTION SUMMARY
11/28/2023 Letter INSPECTION SUMMARY
11/28/2023 Letter INSPECTION SUMMARY
11/29/2023 Letter INSPECTION SUMMARY
12/14/2023 Letter INSPECTION SUMMARY
12/14/2023 Letter INSPECTION SUMMARY
12/14/2023 Letter INSPECTION SUMMARY
12/18/2023 Letter INSPECTION SUMMARY
12/18/2023 Letter INSPECTION SUMMARY
12/27/2023 Letter INSPECTION SUMMARY
12/27/2023 Letter INSPECTION SUMMARY
12/27/2023 1534 sw arbor falls
01/05/2024 Letter INSPECTION SUMMARY
01/05/2024 Letter INSPECTION SUMMARY
01/05/2024 Letter INSPECTION SUMMARY
01/25/2024 Letter INSPECTION SUMMARY
02/07/2024 Letter INSPECTION SUMMARY
02/28/2024 Letter INSPECTION SUMMARY
02/28/2024 Plot Plan approved as graded plot plan
03/01/2024 Letter INSPECTION SUMMARY
03/01/2024 Letter INSPECTION SUMMARY
03/01/2024 Letter INSPECTION SUMMARY
03/04/2024 Letter INSPECTION SUMMARY
03/04/2024 Letter Field Certificate of Occupancy
03/04/2024 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home