Permit Application Status

PRRES20230625


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20230625
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSSES - FINISHED AND UNFINISHED BASEMENT - COVERED DECK
02/14/2023
02/22/2023
08/16/2023
08/14/2023
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
CMH PARKS INC, Address:5000 CLAYTON RD  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sanitary Sewer Development Fee $1,384.00 $1,384.00 Paid 02/22/2023
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 02/22/2023
7232302-Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 02/22/2023
8331401-Water Tap Fee $3,730.00 $3,730.00 Paid 02/22/2023
8350015-Water Meter Fee $550.50 $550.50 Paid 02/22/2023
9110078-Valuation Fee New Single Family $1,444.69 $1,444.69 Paid 02/22/2023
$0.00 $0.00 $0.00 N/A
$0.00 $0.00 $0.00 N/A
$0.00 $0.00 $0.00 N/A
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Failed 3/17/2023 03/17/2023
Misc
Corrective Action Required
03/17/2023
footing poured without inspection, provide third party inspection report. Mitchell Schwarz 03/17/2023 10:02 AM
Piers/Caissons Inspection - Residential Passed 3/20/2023 03/20/2023
Footing Inspection - Residential Passed 3/20/2023 03/20/2023
Misc
Corrective Action Required
03/17/2023
footing poured without inspection, provide third party inspection report. Mitchell Schwarz 03/17/2023 10:02 AM
Underslab Plumbing Inspection - Residential Passed 3/20/2023 3/20/2023 03/20/2023
Sewer Service Inspection - R Passed 4/10/2023 (1:00) 4/10/2023 04/10/2023
Water Service Inspection - R Passed 4/11/2023 (9:15) 4/11/2023 04/11/2023
Electrical Service Inspection Passed 5/5/2023 5/5/2023 05/05/2023
Gas Service Inspection - Residential Passed 5/5/2023 5/5/2023 05/05/2023
All Rough Inspection - Residential Failed 5/5/2023 5/5/2023 05/05/2023
Misc
Corrective Action Required
05/05/2023
-Garage PFH wall sheathing-nail to sill plates @ 3” oc -Rafters above front stoop notched more than max allowed of 25% -Nail siding to sill plates @ 6” oc -Deck: Provide pier support of east deck double trimmer joist at house per plan; install two lag screws at end of ledger board -The 100 amp feeder to the sub panel shall be de-rated for attic temperature -Protect the laundry DVW -Fill in voids behind deck door hinges and at strike plate side per security code with solid wood -The rear great room CSPF wall header not go all to the corner. Siding shall be nailed to CSPF wall headers w/3” grid pattern per plan. -Remove all debris from top of fireplace -Provide tie down of GT A14 at bearing or 20 (kitchen wall) against 1934 lbs of uplift -Brace all trusses per plan -Provide full bearing for roof beam at foyer closet -Provide min 1.5” of bearing of joist onto sill plate (above sump pump) -Toe nail all basement ceiling joists to sill plates and top plates per code -Fb floor at bathroom tub trap; Fb basement wall from soffit/fur down ceiling space -Support DVW @ max 4 ft interval -Fill in voids behind basement door hinges and at strike plate side per security code with solid wood; provide security blockings -Lower basement bathroom supply duct to ceiling level **DO NOT INSULATE
All Rough Inspection - Residential Failed 5/15/2023 5/15/2023 05/15/2023
Misc
Corrective Action Required
05/05/2023
-Rafters above front stoop notched more than max allowed of 25% -Deck: install two lag screws at end of ledger board -The rear great room CSPF nailing to header and interior strap Okay to insulate
All Rough Inspection - Residential Passed 5/19/2023 5/19/2023 05/19/2023
Misc
Resolved
05/19/2023
-Rafters above front stoop notched more than max allowed of 25% -Deck: install two lag screws at end of ledger board -The rear great room CSPF nailing to header and interior strap Okay to insulate
Sidewalk Inspection Partial 5/25/2023 5/25/2023 05/25/2023
Misc
Informational
05/25/2023
5-25-23 PS Performed pre pour inspection for sidewalk, ok to pour sidewalk
Driveway Inspection Partial 5/25/2023 5/25/2023 05/25/2023
Misc
Informational
05/25/2023
5-25-23 PS Performed pre pour inspection on driveway. OK to pour driveway
Sidewalk Inspection Passed 5/30/2023 5/30/2023 05/30/2023
Misc
Informational
05/25/2023
5-25-23 PS Performed pre pour inspection for sidewalk, ok to pour sidewalk 5-30-23 PS Sidewalk meets ADA and LS specifications
Driveway Inspection Passed 5/30/2023 5/30/2023 05/30/2023
Misc
Informational
05/25/2023
5-25-23 PS Performed pre pour inspection on driveway. OK to pour driveway 5-30-23 PS Driveway meets ADA and LS specifications.
Plot Plan Inspection Passed 08/02/2023
Erosion Control Inspection Residential Passed 08/02/2023
Occupancy Inspection - Codes Residential Failed 8/2/2023 8/2/2023 08/02/2023
Misc
Corrective Action Required
08/02/2023
-address open electrical in kitchen -lockouts on all breakers supplying hard wired appliances
Occupancy Inspection - Codes Residential Full C of O 8/14/2023 8/14/2023 08/14/2023
Misc
Resolved
08/14/2023
-address open electrical in kitchen -lockouts on all breakers supplying hard wired appliances
Documents & Images
Date Uploaded File Type Document Name
02/14/2023 HT #168 - Roof truss details
02/14/2023 LOT 168 FINAL
02/14/2023 Permit Codes Residential Plan Review
02/14/2023 Permit Codes Residential Plan Review
02/17/2023 Approved Plans APPROVED PLANS
02/17/2023 Permit Codes Residential Plan Review
02/21/2023 Plot Plan approved plot plan
02/21/2023 3405118 RF LAY 02212023
02/21/2023 Approved Plans APPROVED TRUSS DRAWINGS
02/22/2023 Approved Plans APPROVED PLANS
02/22/2023 Approved Plans APPROVED TRUSS LAYOUT
02/22/2023 Permit Codes Residential Plan Review
02/22/2023 Permit DS Building Permit
02/22/2023 Receipt Receipt for transaction:2023-001018
03/17/2023 Letter INSPECTION SUMMARY
03/17/2023 168 Hawthorn Ridge FTNG
03/20/2023 Letter INSPECTION SUMMARY
03/20/2023 Letter INSPECTION SUMMARY
03/20/2023 Letter INSPECTION SUMMARY
04/10/2023 Letter INSPECTION SUMMARY
04/11/2023 Letter INSPECTION SUMMARY
05/05/2023 Letter INSPECTION SUMMARY
05/05/2023 Letter INSPECTION SUMMARY
05/05/2023 Letter INSPECTION SUMMARY
05/15/2023 Letter INSPECTION SUMMARY
05/19/2023 Letter INSPECTION SUMMARY
05/25/2023 Letter INSPECTION SUMMARY
05/25/2023 Letter INSPECTION SUMMARY
05/30/2023 Letter INSPECTION SUMMARY
05/30/2023 Letter INSPECTION SUMMARY
08/02/2023 Letter INSPECTION SUMMARY
08/02/2023 Letter INSPECTION SUMMARY
08/02/2023 Letter INSPECTION SUMMARY
08/14/2023 Letter Field Certificate of Occupancy
08/14/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home