Permit Application Status

PRRES20226244


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20226244
Building Permit - Residential
Final Completion
DOELING LEONARD K & WILMA J
ALTERATION SINGLE FAMILY
NEW UNCOVERED DECK
12/27/2022
12/27/2022
04/15/2024
Locations
Contacts
DW CONSTRUCTION, Address:801 W 122ND ST, Phone:(816) 872-7661  
  
DOELING LEONARD K & WILMA J, Address:213 NW AMBERSHAM DR  
Reviews
Review Type Outcome Est. Completion Date Completed
Licensed Contractors Approved 12/27/2022 12/27/2022
Brandon Kalwei
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for Add/Alter Single Family $50.00 $50.00 Paid 12/27/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Plot Plan Inspection Passed 1/5/2023 01/05/2023
All Rough Inspection - Residential Failed 1/5/2023 01/05/2023
Misc
Corrective Action Required
01/05/2023
- Provide (2) 1/2' through bolts on all post to beam connections - provide missing joist hangers
Deck Final Inspection - Residential Failed 5/30/2023 5/30/2023 05/30/2023
Misc
Corrective Action Required
05/30/2023
- R507.5.1(2) Provide (2) 1/2" through bolts on each vertical post at to the beam connection. ( not to joist )
Deck Final Inspection - Residential Failed 10/18/2023 10/18/2023 10/18/2023
Misc
Corrective Action Required
05/30/2023
- R507.5.1(2) Provide (2) 1/2" through bolts on each vertical post at to the beam connection. ( not to joist )
Misc
Corrective Action Required
10/18/2023
- No change 10/17/23
Deck Final Inspection - Residential Passed 4/15/2024 04/15/2024
Misc
Resolved
04/15/2024
- R507.5.1(2) Provide (2) 1/2" through bolts on each vertical post at to the beam connection. ( not to joist )
Misc
Resolved
04/15/2024
- No change 10/17/23
All Rough Inspection - Residential Passed 04/15/2024
Misc
Resolved
04/15/2024
- Provide (2) 1/2' through bolts on all post to beam connections
Final Inspection - Residential Passed 04/15/2024
Documents & Images
Date Uploaded File Type Document Name
12/27/2022 Application Form APPROVED PLOT PLAN AND SCOPE OF WORK
12/27/2022 Permit DS Building Permit
12/27/2022 Receipt Receipt for transaction: 2022-009656
12/27/2022 Permit DS Building Permit
01/05/2023 Letter INSPECTION SUMMARY
01/05/2023 Letter INSPECTION SUMMARY
05/25/2023 Letter Codes 140 Day Letter
05/30/2023 Letter INSPECTION SUMMARY
10/17/2023 Letter Codes 140 Day Letter
10/18/2023 Letter INSPECTION SUMMARY
03/11/2024 Letter Codes 140 Day Letter
04/15/2024 Letter INSPECTION SUMMARY
04/15/2024 Letter INSPECTION SUMMARY
04/15/2024 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home