Permit Application Status

PRRES20224434


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20224434
Building Permit - Residential
Final Completion
SEIBOLD CHRISTOPHER J & LESLIE A
NEW OTHER (RESIDENTIAL)
17'x40' INGROUND CONCRETE VINYL SWIMMING POOL. HOMEOWNER IS DOING ELECTRICAL.
09/09/2022
09/27/2022
07/26/2024
Locations
Contacts
COMPLETE OUTDOOR LIVING, Address:29500 EAST ALLEY, Phone:(816) 304-0862  
COMPLETEOUTDOORLIVING@YAHOO.COM  
SEIBOLD CHRISTOPHER J & LESLIE A, Address:2909 NW AUDUBON LN  
TODD AKINS PLUMBING, Address:600 NE MICHAEL DR, Phone:(816) 215-7137  
Reviews
Review Type Outcome Est. Completion Date Completed
Licensed Contractors Approved 09/26/2022 09/26/2022
Andrea Sessler
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New Other $270.00 $270.00 Paid 09/27/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Pool Steel/Bonding - Residential Failed 12/12/2022 12/12/2022 12/12/2022
Misc
Corrective Action Required
12/12/2022
- bonding incomplete
Pool Steel/Bonding - Residential Partial 12/29/2022 12/29/2022 12/29/2022
Misc
Corrective Action Required
12/12/2022
Partial - bonding at 6 points - #4 copper in cover motor pit - Copper to pump location Ok to pour concrete
Gas Piping Inspection - Residential Passed 1/13/2023 1/13/2023 01/13/2023
Miscellaneous Inspection Passed 7/26/2024 07/26/2024
Misc
Informational
07/26/2024
- This is ready for a final inspection.
Pool Steel/Bonding - Residential Passed 7/26/2024 07/26/2024
Misc
Resolved
07/26/2024
Partial - bonding at 6 points - #4 copper in cover motor pit - Copper to pump location Ok to pour concrete
Plot Plan Inspection Passed 7/26/2024 07/26/2024
Pool Final - Residential Passed 7/26/2024 07/26/2024
Final Inspection - Residential Passed 7/26/2024 07/26/2024
Documents & Images
Date Uploaded File Type Document Name
09/09/2022 Letter FENCE AGREEMENT
09/26/2022 Plot Plan APPROVED PLOT PLAN
09/26/2022 Scope of Work SCOPE OF WORK
09/27/2022 Permit DS Building Permit
09/27/2022 Receipt Receipt for transaction:2022-007821
12/12/2022 Letter INSPECTION SUMMARY
12/29/2022 Letter INSPECTION SUMMARY
01/13/2023 Letter INSPECTION SUMMARY
06/02/2023 Letter Codes 140 Day Letter
07/12/2023 Letter Codes 180 Day Letter
07/26/2024 Letter INSPECTION SUMMARY
07/26/2024 Letter INSPECTION SUMMARY
07/26/2024 Letter INSPECTION SUMMARY
07/26/2024 Letter INSPECTION SUMMARY
07/26/2024 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide: