Summary
PRRES20222621
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE. WALKOUT BASEMENT. FINISHED/UNFINISHED BASEMENT. COVERED DECK.
06/13/2022
06/22/2022
12/11/2022
05/12/2023
Locations
Contacts
TRUMARK HOMES, LLC, Address:PO BOX 728, Phone:(816) 564-5613  
MARK A YANCIK, Address:508 nw manor dr  
C.M. MOSE & SON, Address:6603 ROYAL ST BLDG E, Phone:(816) 781-4707  
IMPACT ELECTRICAL SOLUTIONS LLC, Address:14 ANCHOR DRIVE, Phone:(816) 674-9345  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
TRUMARKHOMES.MARK@GMAIL.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $630.00 $630.00 Paid 06/22/2022
Water Tap Fee $3,655.00 $3,655.00 Paid 06/22/2022
Water Meter Fee $479.24 $479.24 Paid 06/22/2022
Right of Way Permit Fee $85.00 $85.00 Paid 06/22/2022
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 06/22/2022
Valuation Fee New Single Family $1,188.50 $1,188.50 Paid 06/22/2022
Not Ready Inspection Fee $75.00 $75.00 Paid 12/10/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 7/11/2022 7/11/2022 07/11/2022
Misc
Informational
07/11/2022
FOOTING APPROVED BY DAVID AINSWORTH ON 7/7/22
Underslab Plumbing Inspection - Residential Passed 7/18/2022 7/18/2022 07/18/2022
Sewer Service Inspection - R Failed 8/26/2022 (8:00) 8/26/2022 08/26/2022
Misc
Corrective Action Required
08/26/2022
-POST ADDRESS -REMOVE TRASH -UNCOVER CONNECTION TO MAIN
Erosion Control Inspection Residential Failed 9/16/2022 09/16/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
09/16/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE, WATTLES -
All Rough Inspection - Residential Failed 9/16/2022 9/16/2022 09/16/2022
Miscellaneous Correction
Corrective Action Required
09/16/2022
PROVIDE ADDRESS MAINTAIN SILT FENCE
Gas Service Inspection - Residential Passed 9/16/2022 9/20/2022 09/20/2022
Electrical Service Inspection Passed 9/20/2022 09/20/2022
Erosion Control Inspection Residential Failed 9/20/2022 09/20/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
09/16/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE, WATTLES -
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
09/20/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - REPLACE SILT FENCE WHEN TRASH CONTRACTOR MOVES HIS TRUCK & TRAILER -
All Rough Inspection - Residential Failed 9/20/2022 09/20/2022
Miscellaneous Correction
Corrective Action Required
09/20/2022
MAINTAIN SILT FENCE
Miscellaneous Correction
Corrective Action Required
09/20/2022
Install doors & windows PFH portal frame fasten top plate to header with 2 rows 16D sinkers @ 3" OC Provide washer & anchor bolt single car garage Solid shim or replace short stud single car garage Strap rafters landing on blocks garage at stoop Seal beam pocket & ufer at garage Provide plumbing nail guard master shower pex Seal upward penetrations master water closet Address ballon framing fireplace wall great room Repair hole in floor master bed Seal upward penetration near stairs/fireplace Tighten anchor bolts basement Seal fire blocking north wall family room SCH 40 columns family room placement not per plan Seal fire blocking at window well & closet bed 3 Seal beam pocket bed 3 Seal fire blocking BED 5 office Solid shim-sister short stud bed 5 Seal beam pocket bed 5 closet Seal fire blocking bed 5 closet Seal dead space & fire block bed 5 shower Seal dead space jack n Jill bath behind tub Seal upward penetrations jack n Jill vanity Seal upward penetrations jack n Jill shower Seal fire blocking bed 4 Provide vertical fire blocking every 10' bed 4 Provide fire blocking flex room at soffit Nail exterior wall sheathing per code
Water Service Inspection - R Passed 9/27/2022 (1:00) 9/27/2022 09/27/2022
All Rough Inspection - Residential Not Ready 9/30/2022 09/30/2022
Miscellaneous Correction
Resolved
09/30/2022
MAINTAIN SILT FENCE
Miscellaneous Correction
Corrective Action Required
09/20/2022
Install doors & windows Seal fire blocking north wall family room ( furr out side gap) SCH 40 columns family room placement not per plan Seal fire blocking at window well & closet bed 3 ( gap at furr out side ) Seal fire blocking BED 5 office ( furr out side gap & line set ) Seal dead space & fire block bed 5 shower ( rock wool / insulation at pex ) Seal fire blocking bed 4 Deck ledger flashed but won't be visible on occupancy not spaced off from trim under it
All Rough Inspection - Residential Failed 10/5/2022 10/05/2022
Miscellaneous Correction
Corrective Action Required
09/30/2022
Install doors & windows Deck ledger flashed but won't be visible on occupancy not spaced off from trim under it OK to insulate
All Rough Inspection - Residential Passed 12/12/2022 12/12/2022
Miscellaneous Correction
Resolved
12/12/2022
Deck ledger flashed but won't be visible on occupancy not spaced off from trim under it OK to insulate
Driveway Inspection Partial 1/3/2023 1/3/2023 01/03/2023
Misc
Informational
01/03/2023
1-3-22 DP. Driveway formed and aggregate placed and compacted. Approved to pour.
Driveway Inspection Passed 1/23/2023 01/10/2023
Misc
Informational
01/03/2023
1-3-22 DP. Driveway formed and aggregate placed and compacted. Approved to pour. 1-10-22 RH. Driveway meets LS specification.
Erosion Control Inspection Residential Failed 2/22/2023 02/22/2023
DCM2 ESC DEFICIENT INSTALLATION
Resolved
02/22/2023
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE, WATTLES -
DCM2 ESC DEFICIENT INSTALLATION
Resolved
02/22/2023
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - REPLACE SILT FENCE WHEN TRASH CONTRACTOR MOVES HIS TRUCK & TRAILER -
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
02/22/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/22/2023
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
02/22/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Occupancy Inspection - Codes Residential Failed 3/20/2023 03/20/2023
Misc
Resolved
03/20/2023
NOTE: HAMMER ARRESTORS IN WALL UNDER LAUNDRY BOX
Misc
Corrective Action Required
03/20/2023
- missing plate covers in garage - Garage pantry door will not self close - Label non GFCI at pump - Need final grade and sod - Missing splash blocks - Sump pump discharge missing extension - Water meter depth needs to be 14-18 inches, currently at 20 inches
Erosion Control Inspection Residential Partial 3/20/2023 03/20/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
03/20/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM2 ESC DEFICIENT INSTALLATION
Resolved
03/20/2023
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
DCM3 ESC REQUIRED 2 DAY
Resolved
03/20/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Misc
Corrective Action Required
03/20/2023
Passed at the time of inspection
Plot Plan Inspection Failed 3/20/2023 03/20/2023
Misc
Corrective Action Required
03/20/2023
Water Meter is to low at time of inspection
Piers/Caissons Inspection - Residential Failed 3/20/2023 03/20/2023
Misc
Corrective Action Required
03/20/2023
Pier inspection report missing
Sewer Service Inspection - R Failed 3/20/2023 03/20/2023
Misc
Corrective Action Required
08/26/2022
-UNCOVER CONNECTION TO MAIN -03/20/2023. Kyle
Sewer Service Inspection - R Passed 4/12/2023 04/12/2023
Misc
Resolved
04/12/2023
-UNCOVER CONNECTION TO MAIN -03/20/2023. Kyle
Piers/Caissons Inspection - Residential Passed 05/12/2023
Misc
Resolved
05/12/2023
Pier inspection report missing
Erosion Control Inspection Residential Passed 05/12/2023
Misc
Resolved
05/12/2023
Passed at the time of inspection
Plot Plan Inspection Passed 05/12/2023
Misc
Resolved
05/12/2023
Water Meter is to low at time of inspection
Occupancy Inspection - Codes Residential Full C of O 5/12/2023 5/12/2023 05/12/2023
Misc
Resolved
05/12/2023
- missing plate covers in garage - Garage pantry door will not self close - Label non GFCI at pump - Need final grade and sod - Missing splash blocks - Sump pump discharge missing extension - Water meter depth needs to be 14-18 inches, currently at 20 inches
Documents & Images
Date Uploaded File Type Document Name
06/13/2022 SKM_C36822061315440
06/13/2022 SKM_C36822061315450
06/14/2022 Approved Plans APPROVED PLANS
06/14/2022 Plot Plan APPROVED PLOT PLAN
06/14/2022 Permit Codes Residential Plan Review
06/17/2022 Permit Codes Residential Plan Review
06/22/2022 Permit DS Building Permit
06/22/2022 Receipt Receipt for transaction:2022-005026
07/08/2022 M L Crose 2071 NW Obrien Rd LSMO Woodside Ridge Lot 179 Trumark Permit 2022-2621 Foundation footing Inspection Report 7-7-22
07/11/2022 Letter INSPECTION SUMMARY
07/18/2022 Letter INSPECTION SUMMARY
08/26/2022 Letter INSPECTION SUMMARY
09/16/2022 Letter INSPECTION SUMMARY
09/16/2022 Letter INSPECTION SUMMARY
09/20/2022 Letter INSPECTION SUMMARY
09/20/2022 Letter INSPECTION SUMMARY
09/20/2022 Letter INSPECTION SUMMARY
09/20/2022 Letter INSPECTION SUMMARY
09/27/2022 Letter INSPECTION SUMMARY
09/30/2022 Letter INSPECTION SUMMARY
10/05/2022 Letter INSPECTION SUMMARY
12/08/2022 Approved Plans APPROVED PAGE 2 OF PLANS
12/10/2022 Receipt Receipt for transaction:2022-009420
12/12/2022 Letter INSPECTION SUMMARY
01/03/2023 Letter INSPECTION SUMMARY
01/10/2023 Letter INSPECTION SUMMARY
02/22/2023 Letter INSPECTION SUMMARY
03/20/2023 Letter INSPECTION SUMMARY
03/20/2023 Letter INSPECTION SUMMARY
03/20/2023 Letter INSPECTION SUMMARY
03/20/2023 Letter INSPECTION SUMMARY
03/20/2023 Letter INSPECTION SUMMARY
03/20/2023 M L Crose 2071 NW Obrien Rd LSMO Woodside Ridge Lot 179 Trumark Permit 2022-2621 Foundation footing Inspection Report 7-7-22 Rev to add deck piers
04/12/2023 179 Woodside Ridge Sewer Letter
04/12/2023 Letter INSPECTION SUMMARY
04/12/2023 179 Woodside Ridge Sewer Letter
05/12/2023 Letter INSPECTION SUMMARY
05/12/2023 Letter INSPECTION SUMMARY
05/12/2023 Letter INSPECTION SUMMARY
05/12/2023 Letter Field Certificate of Occupancy
05/12/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home