Permit Application Status

PRRES20221053


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20221053
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE. FINISHED/UNFINISHED BASEMENT. COVERED PATIO. STOP WORK ORDER generated on 02/16/2024 12:00 AM by username 'Mitchell Schwarz'. STOP WORK ORDER removed on 05/09/2024 12:00 AM by username 'Mitchell Schwarz'.
03/21/2022
06/20/2022
09/28/2022
01/14/2025
Locations
Contacts
SPELLERBERG ENTERPRISES LLC, Address:613 NE VIEWPARK DR, Phone:(816) 550-5535  
Billy Spellerberg, Address:613 ne viewpark dr  
AFC HEATING AND COOLING, Address:824 NW MAIN ST , Phone:(816) 347-8388  
NEW HEIGHTS ELECTRIC LLC, Address:P O BOX 163, Phone:(816) 625-9504  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
SPELLERBERGENTERPRISES@GMAIL.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $600.00 $600.00 Paid 06/20/2022
Water Tap Fee $3,655.00 $3,655.00 Paid 06/20/2022
Water Meter Fee $479.24 $479.24 Paid 06/20/2022
Right of Way Permit Fee $85.00 $85.00 Paid 06/20/2022
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 06/20/2022
Valuation Fee New Single Family $1,497.55 $1,497.55 Paid 06/20/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 6/21/2022 (9:30) 6/21/2022 06/21/2022
Misc
Informational
06/21/2022
ufer ground located SE wall 4' from back cornor
Water Service Inspection - R Partial 7/21/2022 07/21/2022
Misc
Informational
07/21/2022
pex ran from foundation
Sewer Service Inspection - R Passed 7/21/2022 07/21/2022
Water Service Inspection - R Passed 7/22/2022 (9:00) 7/22/2022 07/22/2022
Misc
Resolved
07/22/2022
pex ran from foundation
Underslab Plumbing Inspection - Residential Passed 8/3/2022 8/3/2022 08/03/2022
Corrective Action Required
08/03/2022
Erosion Control Inspection Residential Failed 8/3/2022 08/03/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
08/03/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. repair downed silt fence Mitchell Schwarz 08/03/2022 8:50 AM
Piers/Caissons Inspection - Residential Passed 2/21/2023 (8:00) 2/21/2023 02/21/2023
Erosion Control Inspection Residential Failed 2/22/2023 02/22/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
02/22/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. repair downed silt fence Mitchell Schwarz 08/03/2022 8:50 AM
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
02/22/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/22/2023
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
All Rough Inspection - Residential Failed 4/17/2023 4/17/2023 04/17/2023
Misc
Corrective Action Required
04/17/2023
Inspection denied Provide complete set of plans. Plans have no roof layout. Submit revised set for approval.
All Rough Inspection - Residential Failed 4/26/2023 4/26/2023 04/26/2023
Misc
Resolved
04/26/2023
Inspection denied Provide complete set of plans. Plans have no roof layout. Submit revised set for approval.
Misc
Corrective Action Required
04/26/2023
3209 sw saddlebred -seal penetrations top plate in garage NW Corner -provide nail guards garage N wall where needed for electrical -provide joist hanger at attic access -fireblock E garage wall into furr down -fire block furr down ends in garage -fire block hvac chases to furr down -furr down R/a joist space for insulation in garage at beam -missing nailed in hangers Se garage -address hole/notched/broken floor joist above garage entry bath -top plate penetration 1 floor bed room -seal top plate penetration garage entry into kitchen -support dwv ever 4’ above kitchen -uncover covered patio for inspection -fire block right of great room windows to ceiling space -seal top plate penetration dining room N wall -strike plate where required right of fire place -seal penetrations in return air stud space at stairwell wall -complete exterior cs-pf nailing at dining room exterior per design -roof Perlin supports not plans multiple areas -missing nails in hangers above master closet -missing hanger at attic access 2nd floor -fire block furr down ends. In basement -first block beam ends in basement -fire block vertically to horizontally every 10’ in basement -provide strike plates at electrical where required in basement -anchor all steel columns in basement -provide support for furr down ceiling joist to floor joist above -
All Rough Inspection - Residential Failed 5/10/2023 5/10/2023 05/10/2023
Misc
Corrective Action Required
04/26/2023
-provide nail guards garage N wall where needed for electrical one missing -fireblock E garage wall into furr down (when using Unfaced insulation it must be packed tightly and securely) -fire block furr down ends in garage (when using Unfaced insulation, it must be packed tightly and securely) -uncover covered patio for inspection -address roof Perlin supports not plans multiple areas -missing hanger at attic access 2nd floor -fire block furr down ends. In basement -first block beam ends in basement -provide strike plates at electrical where required in basement one missing -service panel must maintain 36” minimum clearance in front of panel.
Erosion Control Inspection Residential Failed 8/18/2023 08/18/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
02/22/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/22/2023
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
08/18/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Maintain downed silt fence
Erosion Control Inspection Residential Partial 8/23/2023 8/23/2023 08/23/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
08/23/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM2 ESC DEFICIENT INSTALLATION
Resolved
08/23/2023
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
DCM3 ESC REQUIRED 2 DAY
Resolved
08/23/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Maintain downed silt fence
Misc
Informational
08/23/2023
Erosion control back in compliance 8/23/23
All Rough Inspection - Residential Failed 8/30/2023 8/30/2023 08/30/2023
Misc
Corrective Action Required
05/10/2023
-uncover covered patios for inspection
All Rough Inspection - Residential Passed 9/27/2023 9/27/2023 09/27/2023
Misc
Resolved
09/27/2023
-uncover covered patios for inspection
Gas Service Inspection - Residential Failed 10/19/2023 10/19/2023 10/19/2023
Misc
Corrective Action Required
10/19/2023
Provide gas gauge with minimum 10psi for 10min for inspection
Electrical Service Inspection Failed 10/19/2023 10/19/2023 10/19/2023
Misc
Corrective Action Required
10/19/2023
Identify ufer ground connection in breaker panel and at ufer
Gas Service Inspection - Residential Failed 10/24/2023 10/24/2023 10/24/2023
Misc
Corrective Action Required
10/19/2023
Provide gas gauge with minimum 10psi for 10min for inspection Gas gauge only at 5psi
Electrical Service Inspection Passed 10/24/2023 10/24/2023 10/24/2023
Misc
Resolved
10/24/2023
Identify ufer ground connection in breaker panel and at ufer
Gas Service Inspection - Residential Passed 10/24/2023 10/24/2023 10/24/2023
Misc
Corrective Action Required
10/24/2023
Provide gas gauge with minimum 10psi for 10min for inspection Gas gauge only at 5psi
Erosion Control Inspection Residential Failed 02/07/2024
Misc
Resolved
02/07/2024
Erosion control back in compliance 8/23/23
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
02/07/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. No erosion control installed
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/07/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Erosion Control Inspection Residential Failed - Stop Work 02/16/2024
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
02/07/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. No erosion control installed Erosion control still not in compliance 2/16/24
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/07/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
03/11/2024
3-11-24 Dustin A, EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Erosion Control Inspection Residential Partial 5/9/2024 5/9/2024 05/09/2024
Misc
Informational
05/09/2024
Erosion control back in compliance at time of inspection
Driveway Inspection Partial 5/9/2024 5/9/2024 05/09/2024
Misc
Informational
05/09/2024
5-9-24 Dustin A, DW is formed and compacted to city specs, Approved to pour
Driveway Inspection Passed 5/16/2024 5/16/2024 05/16/2024
Misc
Informational
05/09/2024
5-9-24 Dustin A, DW is formed and compacted to city specs, Approved to pour 5-16-24 Dustin A, DW is poured to city specs. Passed
Erosion Control Inspection Residential Passed 3/22/2024 3/22/2024 08/22/2024
DCM3 ESC REQUIRED 2 DAY
Resolved
08/22/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. No erosion control installed Erosion control still not in compliance 2/16/24
DCM2 ESC DEFICIENT INSTALLATION
Resolved
08/22/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Plot Plan Inspection Passed 08/22/2024
Occupancy Inspection - Codes Residential Failed 8/22/2024 8/22/2024 08/22/2024
Misc
Corrective Action Required
08/22/2024
-obtain issued lawn irrigation permit -hand rail required at garage stairs
Occupancy Inspection - Codes Residential Full C of O 1/14/2025 1/14/2025 01/14/2025
Misc
Resolved
01/14/2025
-obtain issued lawn irrigation permit -hand rail required at garage stairs
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home