Summary
PRRES20220630
Building Permit - Residential
Certificate of Occupancy
TRUMARK HOMES LLC
NEW SINGLE FAMILY
NEW HOUSE - PARTIAL FINISHED BASEMENT - COVERED PATIO STOP WORK ORDER generated on 08/17/2022 12:00 AM by username 'Adam Nacke'. STOP WORK ORDER removed on 08/29/2022 12:00 AM by username 'Khanh Nguyen'.
02/21/2022
03/06/2022
08/22/2022
06/22/2023
Locations
Contacts
TRUMARK HOMES, LLC, Address:424 SE MAXWELL DR, Phone:(816) 564-5613  
TRUMARK HOMES LLC, Address:508 NW MANOR DR  
MARK A YANCIK, Address:508 nw manor dr  
C.M. MOSE & SON, Address:6603 ROYAL ST BLDG E, Phone:(816) 781-4707  
IMPACT ELECTRICAL SOLUTIONS LLC, Address:14 ANCHOR DRIVE, Phone:(816) 674-9345  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,375.52 $1,375.52 Paid 03/06/2022
Right of Way Permit Fee $85.00 $85.00 Paid 03/06/2022
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 03/06/2022
8331507-Sewer Connection Fee $570.00 $570.00 Paid 03/06/2022
Water Tap Fee $3,655.00 $3,655.00 Paid 03/06/2022
Water Meter Fee $479.24 $479.24 Paid 03/06/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Failed 3/30/2022 03/30/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
03/30/2022
DEFICIENT EROSION CONTROL INSTALLATION. PROVIDE 6" GRAVEL THE WHOLE WIDTH OF LOT ENTRANCE NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Underslab Plumbing Inspection - Residential Failed 3/30/2022 3/30/2022 03/30/2022
Misc
Corrective Action Required
03/30/2022
-BASEMENT IS FLOODED. NO VISUAL ACCESS
Sewer Service Inspection - R Passed 5/2/2022 5/2/2022 05/02/2022
Water Service Inspection - R Passed 5/3/2022 (10:45) 5/3/2022 05/03/2022
Underslab Plumbing Inspection - Residential Passed 5/10/2022 5/10/2022 05/10/2022
Misc
Resolved
05/10/2022
-BASEMENT IS FLOODED. NO VISUAL ACCESS
Erosion Control Inspection Residential Passed 5/10/2022 05/10/2022
DCM2 ESC DEFICIENT INSTALLATION
Resolved
05/10/2022
DEFICIENT EROSION CONTROL INSTALLATION. PROVIDE 6" GRAVEL THE WHOLE WIDTH OF LOT ENTRANCE NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Piers/Caissons Inspection - Residential Passed 7/14/2022 (8:00) 7/14/2022 07/14/2022
Erosion Control Inspection Residential Failed 07/28/2022
Miscellaneous Correction
Corrective Action Required
07/28/2022
7-28-22 AN silt fence need to be installed and curb inlet needs to be cleaned out
Erosion Control Inspection Residential Failed 07/28/2022
Miscellaneous Correction
Corrective Action Required
07/28/2022
7-28-22 AN silt fence need to be installed and curb inlet needs to be cleaned out
Erosion Control Inspection Residential Failed - Stop Work 8/1/2022 8/1/2022 08/17/2022
Miscellaneous Correction
Corrective Action Required
07/28/2022
7-28-22 AN silt fence need to be installed and curb inlet needs to be cleaned out 8-17-28 AN no effort has been made for erosion control.. erosion control needs to be put in place on all 4 sides of the lot, also trash needs to be cleaned up.
Electrical Service Inspection Passed 8/29/2022 8/29/2022 08/29/2022
Gas Service Inspection - Residential Passed 8/29/2022 8/29/2022 08/29/2022
All Rough Inspection - Residential Failed 8/29/2022 8/29/2022 08/29/2022
Misc
Corrective Action Required
08/29/2022
-Nail garage PFH wall sheathing to sill plate per code; fasten the tension straps to lvl header by Installing blockings and nail garage PFH wall straps; nail all strap holes below lvl header -Have engineer address roof support for the hip/valley/ridge above garage -Fur out garage stair wall at return air space for R-13 insulation -Seal penetrations of return air space above half bathroom -Fb duct chase at each floor/ceiling level -Protect wiring at top plate above refrigerator -Nail front entry wall corner studs per code -Fb plumbing space at bedroom 5 from joist&soffit; Fb floor at trap -Nail hanger at lvl connection above bedroom 5 -Seal gap at wall top plates (return air space at stair/bathroom wall) -Brace end of lvl roof beam from rotation -Provide vertical fire blocking at ten ft or less for basement wall ; Fb wall from soffit **OK TO INSULATE
All Rough Inspection - Residential Failed 9/2/2022 9/2/2022 09/02/2022
Misc
Corrective Action Required
08/29/2022
-Seal gap at wall top plates (return air space at stair/bathroom wall)**Look inside the return air space at bathroom sink. There are gaps at wall top plates that are open to the roof space. Seal these gaps from roof space
All Rough Inspection - Residential Passed 9/6/2022 9/6/2022 09/06/2022
Misc
Resolved
09/06/2022
-Seal gap at wall top plates (return air space at stair/bathroom wall)**Look inside the return air space at bathroom sink. There are gaps at wall top plates that are open to the roof space. Seal these gaps from roof space
Erosion Control Inspection Residential Passed 8/18/2022 8/18/2022 09/09/2022
Miscellaneous Correction
Corrective Action Required
08/17/2022
7-28-22 AN silt fence need to be installed and curb inlet needs to be cleaned out 8-17-28 AN no effort has been made for erosion control.. erosion control needs to be put in place on all 4 sides of the lot, also trash needs to be cleaned up. .
Driveway Inspection Partial 10/19/2022 10/19/2022 10/19/2022
Misc
Informational
10/19/2022
10-19-22 AN forms are in place and aggregate is present and compacted
Driveway Inspection Passed 10/24/2022 10/24/2022 11/04/2022
Misc
Informational
10/19/2022
10-19-22 AN forms are in place and aggregate is present and compacted 10-4-22 AN. Driveway looks good and meets Ada spec
Plot Plan Inspection Passed 2/17/2023 02/17/2023
Footing Inspection - Residential Passed 03/27/2023
Informational
03/27/2023
FOOTING APPROVED BY ENGINEER
Occupancy Inspection - Codes Residential Failed 6/19/2023 6/19/2023 06/19/2023
Misc
Corrective Action Required
06/19/2023
-Install splash block at rear downspout and sump pump extension -Drive grounding rod into ground -Support lawn irrigation pex line every 32” -Provide max 35 amp breaker for AC
Occupancy Inspection - Codes Residential Full C of O 6/22/2023 6/22/2023 06/22/2023
Misc
Resolved
06/22/2023
-Drive grounding rod into ground
Documents & Images
Date Uploaded File Type Document Name
02/21/2022 SKM_C36822022111230
02/21/2022 SKM_C36822022111470
02/23/2022 Permit Codes Residential Plan Review
02/27/2022 67 Monticello added note
02/28/2022 Approved Plans Approved Drawings
03/01/2022 Plot Plan Approved Plot Plan
03/01/2022 Permit Codes Residential Plan Review
03/04/2022 M L Crose 1249 NE Goshen Dr LSMO Monticello Lot 67 Trumark Permit 2022-0630 Foundation Footing Inspection Report 3-3-22
03/06/2022 Permit DS Building Permit
03/06/2022 Receipt Receipt for transaction:2022-001171
03/30/2022 Letter INSPECTION SUMMARY
03/30/2022 Letter INSPECTION SUMMARY
05/02/2022 Letter INSPECTION SUMMARY
05/03/2022 Letter INSPECTION SUMMARY
05/10/2022 Letter INSPECTION SUMMARY
05/10/2022 Letter INSPECTION SUMMARY
07/14/2022 Letter INSPECTION SUMMARY
07/28/2022 Letter INSPECTION SUMMARY
07/28/2022 Letter INSPECTION SUMMARY
07/28/2022 Letter INSPECTION SUMMARY
08/17/2022 Letter Stop Work Order
08/29/2022 Letter INSPECTION SUMMARY
08/29/2022 Letter INSPECTION SUMMARY
08/29/2022 Letter INSPECTION SUMMARY
09/01/2022 Mark Yancik 1249 NE Goshen Dr LSMO MC Lot 67 Inspection Issues Report 9-1-22
09/02/2022 Letter INSPECTION SUMMARY
09/06/2022 Letter INSPECTION SUMMARY
09/09/2022 Letter INSPECTION SUMMARY
10/19/2022 Letter INSPECTION SUMMARY
11/04/2022 Letter INSPECTION SUMMARY
02/16/2023 Plot Plan APPROVED AS GRADED PLOT PLAN
02/17/2023 Letter INSPECTION SUMMARY
03/27/2023 Letter INSPECTION SUMMARY
06/19/2023 Letter INSPECTION SUMMARY
06/22/2023 Letter Codes Final Certificate of Occupancy
06/22/2023 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home