Permit Application Status

PRRES20220522


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20220522
Building Permit - Residential
Certificate of Occupancy
CLAYTON PROPERTIES GROUP INC
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSSES - FINISHED AND UNFINISHED BASEMENT - UNCOVERED DECK -
02/10/2022
02/15/2022
08/13/2022
09/11/2023
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CLAYTON PROPERTIES GROUP INC, Address:120 SE 30TH ST  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $420.00 $420.00 Paid 02/15/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 02/15/2022
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 02/15/2022
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 02/15/2022
8350015-Water Meter Fee $479.24 $479.24 Paid 02/15/2022
9110078-Valuation Fee New Single Family $1,036.19 $1,036.19 Paid 02/15/2022
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 11/30/2022
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 04/03/2023
9110078-Additional Permit Fee $100.00 $100.00 Paid 04/03/2023
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 09/08/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 09/08/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 09/08/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 3/31/2022 3/31/2022 03/31/2022
Misc
Corrective Action Required
03/31/2022
APPROVED PER DAVID P AINSWORTH 3/29/22
Sewer Service Inspection - R Passed 4/11/2022 (11:00) 4/11/2022 04/11/2022
Water Service Inspection - R Passed 4/12/2022 (9:45) 4/12/2022 04/12/2022
Underslab Plumbing Inspection - Residential Passed 4/15/2022 4/15/2022 04/15/2022
Erosion Control Inspection Residential Partial 4/15/2022 4/15/2022 04/15/2022
All Rough Inspection - Residential Not Ready 11/30/2022 11/30/2022 11/30/2022
Misc
Corrective Action Required
11/30/2022
NOT READY FOR ALL ROUGH INSPECTION
Electrical Service Inspection Failed 11/30/2022 11/30/2022 11/30/2022
Misc
Corrective Action Required
11/30/2022
NOT READY FOR ALL ROUGH INSPECTION
Gas Service Inspection - Residential Failed 11/30/2022 11/30/2022 11/30/2022
Misc
Corrective Action Required
11/30/2022
NOT READY FOR ALL ROUGH INSPECTION
Gas Service Inspection - Residential Passed 12/1/2022 12/1/2022 12/01/2022
Misc
Resolved
12/01/2022
NOT READY FOR ALL ROUGH INSPECTION
Electrical Service Inspection Failed 12/1/2022 12/1/2022 12/01/2022
Misc
Corrective Action Required
11/30/2022
-tighten panel bonding screw at service panel
All Rough Inspection - Residential Failed 12/1/2022 12/1/2022 12/01/2022
Misc
Corrective Action Required
11/30/2022
-anchor bolts to be within middle third of sill plate at garage -provide stud shoes at stud bored for SE cable at garage -seal all top plate penetrations at garage -provide protection plate for NM at top plate above service panel -tighten panel bonding screw at service panel -truss hold downs all trusses at garage -tighten LIB x bracing strap at garage -fireblock all tub and shower traps -support all DWV every 48” oc, traps not considered support -provide bocca protection plate top plate DWV great room -solid block between joists above top plate garage/foyer wall -bocca protection plate top plate DWV 2nd floor bath, bedroom -provide H2.5 truss hold downs at both plies of dbl girder truss 2nd floor -have engineer with truss manufacturer address damaged trusses on 2nd floor and trusses as noted having gusset plate separation as noted on received engineer letter from everstead -provide code compliant header design at bed#3 window -provide future vent for basement bath group -(2) 2x10 joist overnotched for anchor bolt at stairwall grade beam basement, min 1 1/2” bearing on wood -solid blocking between joists every 48” at kitchen island,extend one joist bay each side of island per plans
All Rough Inspection - Residential Failed 12/5/2022 12/5/2022 12/05/2022
Misc
Corrective Action Required
12/01/2022
-solid block between joists above top plate garage/foyer wall -land and secure all electrical NM, electrical boxes, bath exhaust fans duct at 2nd floor removed for repairs
All Rough Inspection - Residential Not Ready 12/6/2022 12/6/2022 12/06/2022
Misc
Corrective Action Required
12/05/2022
-land and secure all electrical NM, electrical boxes, bath exhaust fans duct at 2nd floor removed for repairs
Electrical Service Inspection Passed 12/6/2022 12/6/2022 12/06/2022
Misc
Resolved
12/06/2022
-tighten panel bonding screw at service panel
All Rough Inspection - Residential Passed 12/7/2022 12/7/2022 12/07/2022
Misc
Resolved
12/07/2022
Driveway Inspection Partial 1/3/2023 1/3/2023 01/03/2023
Misc
Informational
01/03/2023
1-3-22 RH. Driveway is formed up and aggregate is placed and compacted. Spoke with foreman about expansion joints. Approved to pour.
Driveway Inspection Passed 1/10/2023 1/10/2023 01/10/2023
Misc
Informational
01/03/2023
1-3-22 RH. Driveway is formed up and aggregate is placed and compacted. Spoke with foreman about expansion joints. Approved to pour. 1-10-23 RH. Driveway meets LS specification.
All Rough Inspection - Residential Passed 4/5/2023 4/5/2023 04/05/2023
Misc
Informational
04/05/2023
Basement all rough only
Erosion Control Inspection Residential Failed 4/11/2023 04/11/2023
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
04/11/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Piers/Caissons Inspection - Residential Passed 4/19/2023 (10:45) 4/19/2023 04/19/2023
Erosion Control Inspection Residential Passed 6/27/2023 06/27/2023
DCM3 ESC REQUIRED 2 DAY
Resolved
06/27/2023
Plot Plan Inspection Passed 6/27/2023 06/27/2023
Occupancy Inspection - Codes Residential Failed 6/27/2023 6/27/2023 06/27/2023
Misc
Corrective Action Required
06/27/2023
-Insufficient outlets in the garage -Fire blocking sheet rock required under stairs in basement -GFCI in upstairs hall bathroom did not reset -Remove pressure gauge at sediment trap on gas line and cap off -Conduit loose at A/C disconnect -Seal wall penetration at gas main - Missing caulk above garage sconces
Occupancy Inspection - Codes Residential Temporary C of O 6/29/2023 6/29/2023 06/29/2023
Misc
Resolved
06/29/2023
-Insufficient outlets in the garage -Fire blocking sheet rock required under stairs in basement -GFCI in upstairs hall bathroom did not reset -Remove pressure gauge at sediment trap on gas line and cap off -Conduit loose at A/C disconnect -Seal wall penetration at gas main - Missing caulk above garage sconces
Misc
Corrective Action Required
06/29/2023
Sod to siding must be at least 6 inches in height. Sod must have a 2 percent slope away from the foundation.
Occupancy Inspection - Codes Residential Not Ready 7/19/2023 7/19/2023 07/19/2023
Misc
Corrective Action Required
06/29/2023
Sod to siding must be at least 6 inches in height. Sod must have a 2 percent slope away from the foundation. **MISSING SOD AT DECK NOT READY
Occupancy Inspection - Codes Residential Temporary C of O 8/8/2023 08/02/2023
Misc
Corrective Action Required
07/19/2023
Sod to siding must be at least 6 inches in height. Sod must have a 2 percent slope away from the foundation. **MISSING SOD AT DECK NOT READY
Occupancy Inspection - Codes Residential Ready for Temp CO 8/8/2023 08/08/2023
Misc
Corrective Action Required
08/02/2023
Sod to siding must be at least 6 inches in height. Sod must have a 2 percent slope away from the foundation. **MISSING SOD AT DECK NOT READY
Miscellaneous Correction
Corrective Action Required
08/08/2023
-Sod to siding must be at least 6 inches in height. Sod must have a 2 percent slope away from the foundation. -**MISSING SOD AT DECK NOT READY -Pay all fees associated with permit 08/08/2023 KBEARD
Miscellaneous Inspection Passed 8/8/2023 08/08/2023
Misc
Informational
08/08/2023
Extended temp C of O Sod is still not installed under the deck, grading is not completed to slope away from foundation, 6 inch ground to siding needs to be addressed and all fees need to be paid.
Occupancy Inspection - Codes Residential Full C of O 9/11/2023 9/11/2023 09/11/2023
Misc
Resolved
09/11/2023
Sod to siding must be at least 6 inches in height. Sod must have a 2 percent slope away from the foundation. **MISSING SOD AT DECK NOT READY
Miscellaneous Correction
Resolved
09/11/2023
-Sod to siding must be at least 6 inches in height. Sod must have a 2 percent slope away from the foundation. -**MISSING SOD AT DECK NOT READY -Pay all fees associated with permit 08/08/2023 KBEARD
Documents & Images
Date Uploaded File Type Document Name
02/10/2022 CB #159 - PERMIT APPLICATION
02/11/2022 Approved Plans APPROVED TRUSS DRAWINGS
02/11/2022 Approved Plans APPROVED TRUSS LAYOUT
02/14/2022 Permit Codes Residential Plan Review
02/15/2022 Plot Plan APPROVED PLOT PLAN
02/15/2022 Permit Codes Residential Plan Review
02/15/2022 Permit DS Building Permit
02/15/2022 Receipt Receipt for transaction:2022-000824
02/17/2022 Approved Plans APPROVED PLANS
03/30/2022 M L Crose 3522 SE Corbin Dr LSMO Cobey Creek Lot 159 Clayton Permit 2022-0522 Footing Inspection Report 3-29-22
03/31/2022 Letter INSPECTION SUMMARY
04/11/2022 Letter INSPECTION SUMMARY
04/12/2022 Letter INSPECTION SUMMARY
04/15/2022 Letter INSPECTION SUMMARY
04/15/2022 Letter INSPECTION SUMMARY
04/29/2022 159 COBEY CREEK 1ST FLOOR ROOF LAYOUT - rev 4-29-22
04/29/2022 Plans APPROVED TRUSS LAYOUT
11/30/2022 Letter INSPECTION SUMMARY
11/30/2022 Letter INSPECTION SUMMARY
11/30/2022 Letter INSPECTION SUMMARY
11/30/2022 Receipt Receipt for transaction:2022-009199
11/30/2022 159 cobey creek truss inspection letter- signed
12/01/2022 Letter INSPECTION SUMMARY
12/01/2022 Letter INSPECTION SUMMARY
12/01/2022 Letter INSPECTION SUMMARY
12/02/2022 3008841 A2A, A4, A5 repairs
12/05/2022 159 cobey creek header letter- signed
12/05/2022 Letter INSPECTION SUMMARY
12/06/2022 Letter INSPECTION SUMMARY
12/06/2022 Letter INSPECTION SUMMARY
12/07/2022 Letter INSPECTION SUMMARY
01/03/2023 Letter INSPECTION SUMMARY
01/10/2023 Letter INSPECTION SUMMARY
03/24/2023 CB #159 - Sage - Farmhouse ELEV 3 - BASEMENT FINISH - signed
03/28/2023 CB 159 Basement Finish App
03/29/2023 Approved Plans APPROVED PLANS
04/03/2023 Receipt Receipt for transaction:2023-001846
04/05/2023 Letter INSPECTION SUMMARY
04/19/2023 Letter INSPECTION SUMMARY
06/27/2023 Letter INSPECTION SUMMARY
06/27/2023 Letter INSPECTION SUMMARY
06/27/2023 Letter INSPECTION SUMMARY
06/27/2023 Letter INSPECTION SUMMARY
06/29/2023 Certificate/License Codes Temporary Certificate of Occupancy
07/19/2023 Letter INSPECTION SUMMARY
08/02/2023 Certificate/License Codes Temporary Certificate of Occupancy
08/08/2023 Letter INSPECTION SUMMARY
09/08/2023 Certificate/License Codes Temporary Certificate of Occupancy
09/08/2023 Certificate/License Codes Temporary Certificate of Occupancy
09/08/2023 Receipt Receipt for transaction:2023-006906
09/11/2023 Letter Codes Final Certificate of Occupancy
09/11/2023 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home