Permit Application Status

PRRES20220403


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20220403
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSSES - UNFINISHED BASEMENT - COVERED PATIO
01/31/2022
02/10/2022
12/19/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CMH PARKS INC, Address:5000 CLAYTON RD  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $600.00 $600.00 Paid 02/10/2022
Right of Way Permit Fee $85.00 $85.00 Paid 02/10/2022
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 02/10/2022
Valuation Fee New Single Family $1,436.15 $1,436.15 Paid 02/10/2022
Water Tap Fee $3,655.00 $3,655.00 Paid 02/10/2022
Water Meter Fee $479.24 $479.24 Paid 02/10/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Sewer Service Inspection - R Passed 4/7/2022 (11:00) 4/7/2022 04/07/2022
Water Service Inspection - R Passed 4/8/2022 (10:15) 4/8/2022 04/08/2022
Underslab Plumbing Inspection - Residential Passed 4/15/2022 4/15/2022 04/15/2022
Footing Inspection - Residential Passed 4/25/2022 04/25/2022
Misc
Informational
04/25/2022
third party inspection performed
Electrical Service Inspection Passed 7/11/2022 7/11/2022 07/11/2022
All Rough Inspection - Residential Failed 7/11/2022 7/11/2022 07/11/2022
Misc
Corrective Action Required
07/11/2022
-missing hold down on truss at single car -seal top plate penetration at single car garage -fire block furr outs in garage to furr down, seal penetrations in garage E wall into furr down -address holes in floor joist above garage near furr down for dwv drilled closer than 2” to edge -seal under 2nd floor tub in garage furr down -address broken floor joist above great room hvac chase right of windows -address broken bath vent line above great room -fire block hvac chases into furr down at great room windows -address over bored stud at fireplace -address over bored stud above bed 5 closet for dwv -hold downs for gt truss above bath 2 -hold downs for gt truss above bed 5 closet -hold down for gt truss above master closet S wall -protect NM With in 6’ of attic access 2nd floor -missing nails in truss hanger above steal column in garage -missing hanger at N most front stoop truss -missing truss hangers at back patio -add solid blocking as needed under kitchen island -flood lamp at back of home -complete gas line
Gas Service Inspection - Residential Failed 7/15/2022 7/15/2022 07/15/2022
Misc
Corrective Action Required
07/15/2022
Pressure gauge stuck at 15psi
All Rough Inspection - Residential Failed 7/19/2022 7/19/2022 07/19/2022
Misc
Corrective Action Required
07/11/2022
-address holes in floor joist above garage near furr down for dwv drilled closer than 2” to edge -address broken bath vent line above great room -address over bored stud at fireplace -address over bored stud above bed 5 closet for dwv -hold downs for gt truss above bath 2 (install correctly) -protect NM With in 6’ of attic access 2nd floor -missing hanger at N most front stoop truss(patio covered) -missing truss hangers at back patio (covered) -flood lamp at back of home
Gas Service Inspection - Residential Passed 7/19/2022 07/19/2022
Misc
Resolved
07/19/2022
Pressure gauge stuck at 15psi
All Rough Inspection - Residential Passed 7/22/2022 7/22/2022 07/22/2022
Misc
Resolved
07/22/2022
-address holes in floor joist above garage near furr down for dwv drilled closer than 2” to edge -address broken bath vent line above great room -address over bored stud at fireplace -address over bored stud above bed 5 closet for dwv -hold downs for gt truss above bath 2 (install correctly) -protect NM With in 6’ of attic access 2nd floor -missing hanger at N most front stoop truss(patio covered) -missing truss hangers at back patio (covered) -flood lamp at back of home
Driveway Inspection Partial 8/19/2022 8/19/2022 08/19/2022
Misc
Informational
08/19/2022
8-19-22 RH. Driveway was formed up and aggregate was place and compacted.
Sidewalk Inspection Partial 8/19/2022 8/19/2022 08/19/2022
Misc
Informational
08/19/2022
8-19-22 RH. Sidewalk was formed up and aggregate was placed and compacted.
Driveway Inspection Passed 8/26/2022 8/26/2022 08/26/2022
Misc
Informational
08/19/2022
8-19-22 RH. Driveway was formed up and aggregate was place and compacted. 8-26-22 RH. Driveway meets LS and ADA Specification.
Sidewalk Inspection Passed 8/26/2022 8/26/2022 08/26/2022
Misc
Informational
08/19/2022
8-19-22 RH. Sidewalk was formed up and aggregate was placed and compacted. 8-26-22 RH. Sidewalk meets LS and ADA Specification.
Plot Plan Inspection Passed 9/15/2022 09/15/2022
Erosion Control Inspection Residential Passed 12/8/2022 12/08/2022
Occupancy Inspection - Codes Residential Failed 12/8/2022 12/8/2022 12/08/2022
Misc
Corrective Action Required
12/08/2022
- Provide pier inspection - Lower water meter lid to grade - Label non gfci outlets, garage and basement - Provide lock outs were needed in electrical panel
Piers/Caissons Inspection - Residential Passed 12/15/2022 12/15/2022
Occupancy Inspection - Codes Residential Failed 12/15/2022 12/15/2022 12/15/2022
Misc
Corrective Action Required
12/08/2022
- Provide lock outs were needed in electrical panel(hardwired kitchen appliances)
Occupancy Inspection - Codes Residential Failed 12/21/2022 12/21/2022 12/21/2022
Misc
Corrective Action Required
12/15/2022
- Provide lock outs were needed in electrical panel(hardwired kitchen appliances) NOT DONE
Occupancy Inspection - Codes Residential Full C of O 12/29/2022 12/29/2022 12/29/2022
Misc
Resolved
12/29/2022
- Provide lock outs were needed in electrical panel(hardwired kitchen appliances) NOT DONE
Documents & Images
Date Uploaded File Type Document Name
01/31/2022 HT #146 - PERMIT APP
02/01/2022 Approved Plans APPROVED PLANS
02/01/2022 Approved Plans APPROVED TRUSS LAYOUT
02/01/2022 Approved Plans APPROVED TRUSS PACKAGE
02/01/2022 Plot Plan APPROVED PLOT PLAN
02/01/2022 Permit Codes Residential Plan Review
02/10/2022 Permit DS Building Permit
02/10/2022 Receipt Receipt for transaction:2022-000726
04/07/2022 Letter INSPECTION SUMMARY
04/08/2022 Letter INSPECTION SUMMARY
04/12/2022 146 Hawthorne Ridge FTNG
04/15/2022 Letter INSPECTION SUMMARY
04/25/2022 Letter INSPECTION SUMMARY
06/28/2022 146 Hawthorne Ridge Field Issue
07/11/2022 Letter INSPECTION SUMMARY
07/11/2022 Letter INSPECTION SUMMARY
07/15/2022 Letter INSPECTION SUMMARY
07/20/2022 146 Hawthorne Ridge Field Issue 2
07/21/2022 Letter INSPECTION SUMMARY
07/21/2022 Letter INSPECTION SUMMARY
07/22/2022 Letter INSPECTION SUMMARY
08/19/2022 Letter INSPECTION SUMMARY
08/19/2022 Letter INSPECTION SUMMARY
08/26/2022 Letter INSPECTION SUMMARY
08/26/2022 Letter INSPECTION SUMMARY
09/14/2022 Plot Plan APPROVED AS GRADED PLOT PLAN
12/08/2022 Letter INSPECTION SUMMARY
12/08/2022 Letter INSPECTION SUMMARY
12/12/2022 146 Hawthorne Ridge Deck Piers
12/21/2022 Letter INSPECTION SUMMARY
12/21/2022 Letter INSPECTION SUMMARY
12/21/2022 Letter INSPECTION SUMMARY
12/21/2022 Letter INSPECTION SUMMARY
12/29/2022 Letter Field Certificate of Occupancy
12/29/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home