Permit Application Status

PRRES20220180


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20220180
Building Permit - Residential
Certificate of Occupancy
CLAYTON PROPERTIES GROUP INC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED PATIO
01/14/2022
01/19/2022
12/22/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CLAYTON PROPERTIES GROUP INC, Address:120 SE 30TH ST  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Tyler Lockler, Address:120 SE 30th St  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,035.75 $1,035.75 Paid 01/19/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 01/19/2022
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 01/19/2022
8331507-Sewer Connection Fee $360.00 $360.00 Paid 01/19/2022
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 01/19/2022
8350015-Water Meter Fee $479.24 $479.24 Paid 01/19/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 03/15/2022
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 08/17/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 2/10/2022 (1:30) 2/10/2022 02/10/2022
Sewer Service Inspection - R Passed 2/24/2022 (9:00) 2/24/2022 02/24/2022
Water Service Inspection - R Passed 2/24/2022 (9:00) 2/24/2022 02/24/2022
Underslab Plumbing Inspection - Residential Failed 2/24/2022 2/24/2022 02/24/2022
Misc
Corrective Action Required
02/24/2022
NO INSPECTION PERFORMED - POST SITE ADDRESS - BACKFILL AT FOUNDATION TO ALLOW FOR INSPECTION
Underslab Plumbing Inspection - Residential Not Ready 3/9/2022 3/9/2022 03/09/2022
Misc
Corrective Action Required
02/24/2022
INSPECTION DENIED EROSION CONTROL REQUIRED TO BE IN COMLIANCE (NO EROSION CONTROL PRESENT AT STREET FRONT OF LOT AT INSPECTION) GRAVEL FILTER REQUIRED ON DRIVE, MIN 3/4" 6" LIFT
Erosion Control Inspection Residential Failed 3/9/2022 3/9/2022 03/09/2022
Misc
Corrective Action Required
03/09/2022
INSPECTION DENIED EROSION CONTROL REQUIRED TO BE IN COMLIANCE (NO EROSION CONTROL PRESENT AT STREET FRONT OF LOT AT INSPECTION) GRAVEL FILTER REQUIRED ON DRIVE, MIN 3/4" 6" LIFT
Underslab Plumbing Inspection - Residential Passed 3/22/2022 3/22/2022 03/22/2022
Misc
Resolved
03/22/2022
INSPECTION DENIED EROSION CONTROL REQUIRED TO BE IN COMLIANCE (NO EROSION CONTROL PRESENT AT STREET FRONT OF LOT AT INSPECTION) GRAVEL FILTER REQUIRED ON DRIVE, MIN 3/4" 6" LIFT
All Rough Inspection - Residential Failed 8/10/2022 8/10/2022 08/10/2022
Misc
Corrective Action Required
08/10/2022
PFH portal frame, nail 2x4 to header per plan 2 rows @ 3” on center #16 sinkers Unable to inspect patio cover, please remove a corner sheeting Front door entry wall not tied in at top plate, strap corners Nail all exterior corners per plan Missing hanger truss to girder kitchen @ bedroom 2 Anchor steel column bottom of stairs Solid block cantilever basement into garage
Electrical Service Inspection Passed 8/10/2022 8/10/2022 08/10/2022
Gas Service Inspection - Residential Passed 8/10/2022 8/10/2022 08/10/2022
All Rough Inspection - Residential Not Ready 8/17/2022 8/17/2022 08/17/2022
Misc
Corrective Action Required
08/10/2022
PFH portal frame, nail 2x4 to header per plan 2 rows @ 3” on center #16 sinkers Unable to inspect patio cover, please remove a corner UNCOVER WHOLE PATIO HOLD DOWNS NOT INSTALLED PROPERLY (Not attached to top plate Nail all exterior corners per plan Missing hanger truss to girder kitchen @ bedroom 2
All Rough Inspection - Residential Failed 8/25/2022 8/25/2022 08/25/2022
Misc
Corrective Action Required
08/17/2022
PFH portal frame, nail 2x4 to header per plan 2 rows @ 3” on center #16 sinkers 8/28/22 - UPLOAD MANUFACTURER DOCUMENTATION ON TRUSS HOLD DOWNS USED AT COVERED DECK, CONFIRM SCREWS USED ARE DESIGNED AS TRUSS HOLD DOWNS
All Rough Inspection - Residential Passed 8/30/2022 8/30/2022 08/30/2022
Misc
Resolved
08/30/2022
Driveway Inspection Passed 9/8/2022 9/8/2022 09/08/2022
Misc
Informational
09/08/2022
On Thursday, 9-08-2022. I performed and passed a driveway for placement of concrete.
Occupancy Inspection - Codes Residential Failed 11/30/2022 11/30/2022 11/30/2022
Misc
Corrective Action Required
11/30/2022
- no pier inspection performed on covered patio piers -maintain erosion control on lot until sod is placed -pan off fireblock cantilevers at garage -label all dedicated receptacles at garage and unfinished space as not GFCI protected -garage door must be self closing, adjust spring hinges -install cover plate at pantry -hot water heater discharge pipe min 2X pipe diameter AFF, maximum 6” AFF -AFCI protection required at washer circuit -sod -splash blocks -seal all penetrations in siding -uncover water meter lid
Piers/Caissons Inspection - Residential Passed 12/22/2022
Plot Plan Inspection Passed 12/1/2022 12/22/2022
Erosion Control Inspection Residential Passed 12/22/2022
Misc
Resolved
12/22/2022
INSPECTION DENIED EROSION CONTROL REQUIRED TO BE IN COMLIANCE (NO EROSION CONTROL PRESENT AT STREET FRONT OF LOT AT INSPECTION) GRAVEL FILTER REQUIRED ON DRIVE, MIN 3/4" 6" LIFT
Occupancy Inspection - Codes Residential Full C of O 12/22/2022 12/22/2022 12/22/2022
Misc
Resolved
12/22/2022
-install cover plate at pantry -hot water heater discharge pipe min 2X pipe diameter AFF, maximum 6” AFF -AFCI protection required at washer circuit
Documents & Images
Date Uploaded File Type Document Name
01/14/2022 CB #16 - PERMIT APPLICATION
01/19/2022 Approved Plans Approved Drawings
01/19/2022 Approved Plans Approved Truss Layout
01/19/2022 Approved Plans Approved Truss Package
01/19/2022 Plot Plan Approved Plot Plan
01/19/2022 Permit Codes Residential Plan Review
01/19/2022 Permit DS Building Permit
01/19/2022 Receipt Receipt for transaction:2022-000323
02/10/2022 Letter INSPECTION SUMMARY
02/24/2022 Letter INSPECTION SUMMARY
02/24/2022 Letter INSPECTION SUMMARY
02/24/2022 Letter INSPECTION SUMMARY
03/09/2022 Letter INSPECTION SUMMARY
03/09/2022 Letter INSPECTION SUMMARY
03/15/2022 Receipt Receipt for transaction:2022-001395
08/10/2022 Letter INSPECTION SUMMARY
08/10/2022 Letter INSPECTION SUMMARY
08/10/2022 Letter INSPECTION SUMMARY
08/17/2022 Letter INSPECTION SUMMARY
08/17/2022 Receipt Receipt for transaction:2022-006778
08/25/2022 Letter INSPECTION SUMMARY
08/29/2022 Strong-Drive® SDWC TRUSS PT3
08/30/2022 Letter INSPECTION SUMMARY
09/08/2022 Letter INSPECTION SUMMARY
11/29/2022 LOT 16 ASBUILT 11-11-22
11/29/2022 Plot Plan APPROVED AS GRADED PLOT PLAN
11/30/2022 Letter INSPECTION SUMMARY
12/21/2022 CB16 PIERS
12/22/2022 Letter INSPECTION SUMMARY
12/22/2022 Letter INSPECTION SUMMARY
12/22/2022 Letter INSPECTION SUMMARY
12/22/2022 Letter Field Certificate of Occupancy
12/22/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home