Permit Application Status

PRRES20220169


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20220169
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE. WALKOUT BASEMENT. FINISHED/UNFINISHED BASEMENT. COVERED DECK.
01/13/2022
01/24/2022
04/28/2023
Locations
Contacts
ASPEN HOME BUILDERS LLC, Address:6618 ROYAL ST #B, Phone:(816) 507-0123  
Steve Gilliland, Address:6618 Royal Street  
MCDANIEL FURNACE & SHEET METAL, Address:2905 S M 291 FRONTAGE RD, Phone:(816) 373-6370  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
trevor@aspenhomeskc.com  
N & E Plumbing LLC, Address:17301 Jennifer St.  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $390.00 $390.00 Paid 01/24/2022
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 01/24/2022
8350015-Water Meter Fee $479.24 $479.24 Paid 01/24/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 01/24/2022
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 01/24/2022
9110078-Valuation Fee New Single Family $1,099.31 $1,099.31 Paid 01/24/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 2/15/2022 (9:00) 2/15/2022 02/15/2022
Underslab Plumbing Inspection - Residential Passed 4/22/2022 4/22/2022 04/22/2022
Sewer Service Inspection - R Passed 6/6/2022 (1:00) 6/6/2022 06/06/2022
Water Service Inspection - R Passed 6/8/2022 (2:30) 6/8/2022 06/08/2022
Piers/Caissons Inspection - Residential Passed 10/5/2022 10/05/2022
Gas Service Inspection - Residential Failed 10/7/2022 10/7/2022 10/07/2022
Misc
Corrective Action Required
10/07/2022
complete gas line install at fire place for inspection.
Electrical Service Inspection Passed 10/7/2022 10/7/2022 10/07/2022
All Rough Inspection - Residential Failed 10/7/2022 10/7/2022 10/07/2022
Misc
Corrective Action Required
10/07/2022
-install collar ties to code -provide lib’s throughout -seal top plate penetration in bed 2 -midway strap all dwv 2” in diameter or less in stud bays -complete bath vents at S side of home -fire block furr down ends in basement -address over notched studs see N wall -address anchor bolts at basement door (missing and incorrectly placed) anchor bolts -seal gaps into furr down in basement bath -complete RA panning in furr down near bath and hall -add stud at basement furnace area where missing -add vertical to horizontal fireblocking at bed 4 S wall -seal penetrations into return air joist space in bed 4
All Rough Inspection - Residential Failed 10/12/2022 10/12/2022 10/12/2022
Misc
Corrective Action Required
10/07/2022
-midway strap all dwv 2” in diameter or less in stud bays see rec room -fire block furr down ends in basement see rec room seal penetration W wall -seal gaps into furr down in basement bath -add vertical to horizontal fireblocking at bed 4 S wall foam penetration OKAY TO INSULATE DO NOT COVER ANY ITEMS IN NEED OF INSPECTION
All Rough Inspection - Residential Passed 10/14/2022 10/14/2022 10/14/2022
Misc
Resolved
10/14/2022
-midway strap all dwv 2” in diameter or less in stud bays see rec room -fire block furr down ends in basement see rec room seal penetration W wall -seal gaps into furr down in basement bath -add vertical to horizontal fireblocking at bed 4 S wall foam penetration
Erosion Control Inspection Residential Failed 11/3/2022 11/03/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
11/03/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. 11/3/22 -Provide erosion control methods at front of lot
Gas Service Inspection - Residential Failed 11/3/2022 11/3/2022 11/03/2022
Misc
Corrective Action Required
10/07/2022
complete gas line install at fire place for inspection. **11/3/22-NO ACCESS, ADDRESS EROSION CONTROL BEFORE SCHEDULING FURTHER INSPECTIONS
Gas Service Inspection - Residential Passed 11/4/2022 11/4/2022 11/04/2022
Misc
Resolved
11/04/2022
complete gas line install at fire place for inspection. **11/3/22-NO ACCESS, ADDRESS EROSION CONTROL BEFORE SCHEDULING FURTHER INSPECTIONS
Driveway Inspection Partial 12/6/2022 12/6/2022 12/06/2022
Misc
Informational
12/06/2022
12-6-22 RH. Driveway is formed up and aggregate is placed and compacted. Approved to pour.
Driveway Inspection Passed 12/13/2022 12/13/2022 12/13/2022
Misc
Informational
12/06/2022
12-6-22 RH. Driveway is formed up and aggregate is placed and compacted. Approved to pour. 12-13-22 RH. Driveway passed LS specification.
Piers/Caissons Inspection - Residential Passed 2/2/2023 (11:30) 2/2/2023 02/02/2023
Sidewalk Inspection Partial 4/21/2023 4/21/2023 04/21/2023
Misc
Informational
04/21/2023
4-21-23 RH. Sidewalk is formed up and aggregate is placed and compacted. Approved to pour.
Erosion Control Inspection Residential Passed 04/24/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
04/24/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. 11/3/22 -Provide erosion control methods at front of lot
Sidewalk Inspection Passed 4/24/2023 4/24/2023 04/24/2023
Misc
Informational
04/21/2023
4-21-23 RH. Sidewalk is formed up and aggregate is placed and compacted. Approved to pour. 4-24-23 RH. Sidewalk meets LS and ADA specification.
Occupancy Inspection - Codes Residential Failed 4/24/2023 4/24/2023 04/24/2023
Misc
Corrective Action Required
04/24/2023
-address pending sidewalk inspection -handrail required in garage -label all non GFCI outlets in unfinished spaces -security screws for back doors -uncover water meter -identify sewer tracer wire
Plot Plan Inspection Passed 04/28/2023
Occupancy Inspection - Codes Residential Full C of O 4/28/2023 4/28/2023 04/28/2023
Misc
Resolved
04/28/2023
-handrail required in garage (handrail height to be 34”-38” from nosing of tread -label all non GFCI outlets in unfinished spaces -security screws for back doors -uncover water meter -identify sewer tracer wire
Documents & Images
Date Uploaded File Type Document Name
01/13/2022 Lot 73 Permit App
01/13/2022 Lot 73 Tax App
01/19/2022 Plot Plan APPROVED PLOT PLAN
01/19/2022 Permit Codes Residential Plan Review
01/24/2022 Permit DS Building Permit
01/24/2022 Receipt Receipt for transaction:2022-000384
02/15/2022 Letter INSPECTION SUMMARY
02/15/2022 Letter COMBUSTION LETTER
02/15/2022 Approved Plans APPROVED DRAWINGS
02/15/2022 Letter INSPECTION SUMMARY
04/22/2022 Letter INSPECTION SUMMARY
06/06/2022 Letter INSPECTION SUMMARY
06/08/2022 Letter INSPECTION SUMMARY
10/05/2022 Letter INSPECTION SUMMARY
10/07/2022 Letter INSPECTION SUMMARY
10/07/2022 Letter INSPECTION SUMMARY
10/07/2022 Letter INSPECTION SUMMARY
10/12/2022 Letter INSPECTION SUMMARY
10/12/2022 Letter INSPECTION SUMMARY
10/14/2022 Letter INSPECTION SUMMARY
11/03/2022 Letter INSPECTION SUMMARY
11/03/2022 Letter INSPECTION SUMMARY
11/04/2022 Letter INSPECTION SUMMARY
12/06/2022 Letter INSPECTION SUMMARY
12/13/2022 Letter INSPECTION SUMMARY
02/02/2023 Letter INSPECTION SUMMARY
04/21/2023 Letter INSPECTION SUMMARY
04/24/2023 Letter INSPECTION SUMMARY
04/24/2023 Letter INSPECTION SUMMARY
04/24/2023 Letter INSPECTION SUMMARY
04/28/2023 Letter INSPECTION SUMMARY
04/28/2023 Letter Field Certificate of Occupancy
04/28/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.