Summary
PRRES20215296
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSSES - FINISHED AND UNFINISHED BASEMENT - COVERED DECK STOP WORK ORDER generated on 12/10/2021 12:00 AM by username 'Patrick Schonfeldt'. STOP WORK ORDER removed on 12/14/2021 12:00 AM by username 'Patrick Schonfeldt'.
10/11/2021
10/18/2021
11/18/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CMH PARKS INC, Address:5000 CLAYTON RD  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $420.00 $420.00 Paid 10/18/2021
Right of Way Permit Fee $85.00 $85.00 Paid 10/18/2021
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 10/18/2021
Water Tap Fee $3,655.00 $3,655.00 Paid 10/18/2021
Water Meter Fee $479.24 $479.24 Paid 10/18/2021
Valuation Fee New Single Family $1,097.27 $1,097.27 Paid 10/18/2021
Not Ready Inspection Fee $50.00 $50.00 Paid 06/09/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Failed 12/10/2021 12/10/2021 12/10/2021
Misc
Corrective Action Required
12/10/2021
INSPECTION DENIED FOOTING POURED WITHOUT INSPECTION
Footing Inspection - Residential Failed - Stop Work 12/10/2021 12/10/2021 12/10/2021
Misc
Corrective Action Required
12/10/2021
FOOTING POURED WITHOUT INSPECTION SUBMIT ENGINEER REPORT, ENGINEER REPORT REQUIRED TO BE UPLOADED TO PERMIT WITHIN 48 HOURS OF INSPECTION
Footing Inspection - Residential Passed 12/14/2021 12/14/2021 12/14/2021
Misc
Informational
12/14/2021
APPROVED PER BRADLEY HUXOL 11/11/21
Underslab Plumbing Inspection - Residential Passed 12/15/2021 12/15/2021 12/15/2021
Misc
Resolved
12/15/2021
INSPECTION DENIED FOOTING POURED WITHOUT INSPECTION
Sewer Service Inspection - R Passed 1/18/2022 01/18/2022
Water Service Inspection - R Passed 1/19/2022 1/19/2022 01/19/2022
Erosion Control Inspection Residential Failed 1/28/2022 01/28/2022
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
01/28/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -repair downed silt fence -maintain lot access -clean up curb
Erosion Control Inspection Residential Failed 5/17/2022 5/17/2022 05/17/2022
DCM3 ESC REQUIRED 2 DAY
Resolved
05/17/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -repair downed silt fence -maintain lot access -clean up curb
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
05/17/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -maintain gravel filter -clean storm inlet
Electrical Service Inspection Passed 5/17/2022 5/17/2022 05/17/2022
Gas Service Inspection - Residential Failed 5/17/2022 5/17/2022 05/17/2022
Misc
Corrective Action Required
05/17/2022
Complete gas line installation at fireplace
All Rough Inspection - Residential Failed 5/17/2022 5/17/2022 05/17/2022
Misc
Corrective Action Required
05/17/2022
No further inspections until erosion control is in compliance -anchor bolts to be tight and within 12” of plate breaks but not closer than 7X the diameter of the bolt see garage -missing lib bracing everywhere -protect all NM within 6’ of attic access -seal all top plate penetrations in garage -strap top plate where lapped less than 24” in garage near entry -address truss to top plate connections throughout -address broken truss above owners entry -fireblock dead space at owners entry/laundry -address dryer vent length -midway strap all dwv 2” in diameter or less -address sheathing does not extend to top plate -fire block penetrations at fireplace -complete gas line install -protect and secure gas line at fireplace -fireblock top of fireplace -cspf at dining room windows -fireblock furr out wall at kitchen seal gaps -fireblock dead space great room to foyer -uncover covered patio for inspection -fire block under entry tub -missing truss hanger above bed 2 closet -seal penetrations in vertical to horizontal fireblock if in basement -fireblock furr down ends -solid block under kitchen island per plans -fireblock furr out wall NW wall basement -seal penetrations for pex in fireblock if N wall -secure and protect gas line above rec room windows -fire block top of furr out walls in basement (seal gaps) -address over notched stud bed 3 N wall -anchor bolts in basement to be in the middle 1/3 of sill plate -nail all exterior sheathing to plans/code
All Rough Inspection - Residential Failed 6/1/2022 6/1/2022 06/01/2022
Misc
Corrective Action Required
05/17/2022
-protect all NM within 6’ of attic access -address broken truss above owners entry [ more than one ] letter addresses 1 break I see 3.on 2 trusses -address dryer vent length -midway strap all dwv 2” in diameter or less -missing windows bedroom 2
All Rough Inspection - Residential Failed 6/7/2022 6/7/2022 06/07/2022
Misc
Corrective Action Required
06/01/2022
-address dryer vent length must comply with code section M1502.4.5 of the IRC
Gas Service Inspection - Residential Passed 6/7/2022 6/7/2022 06/07/2022
Misc
Resolved
06/07/2022
Complete gas line installation at fireplace
All Rough Inspection - Residential Not Ready 6/8/2022 6/8/2022 06/08/2022
Misc
Corrective Action Required
06/07/2022
-address dryer vent length must comply with code section M1502.4.5 of the IRC
All Rough Inspection - Residential Passed 6/10/2022 6/10/2022 06/10/2022
Misc
Resolved
06/10/2022
-address dryer vent length must comply with code section M1502.4.5 of the IRC
Driveway Inspection Passed 6/14/2022 6/14/2022 06/14/2022
Misc
Informational
06/14/2022
On Tuesday, 6-14-2022. I performed and passed a driveway inspection for concrete placement.
Sidewalk Inspection Passed 6/14/2022 6/14/2022 06/14/2022
Misc
Informational
06/14/2022
On Tuesday, 6-14-2022. I performed and passed sidewalk inspection for placement of concrete.
Plot Plan Inspection Passed 8/9/2022 08/09/2022
Occupancy Inspection - Codes Residential Failed 11/3/2022 11/3/2022 11/03/2022
Misc
Corrective Action Required
11/03/2022
-final sidewalk inspection required, contact development services to schedule -provide GFCI protection at wall outlet wet bar right of fridge, less than 6’ from wet bar sink -downspout and sump pump discharge min 36” distance from foundation -provide angle clip at inner ply of dbl beam at deck -no larger than 7 3/4” rise and no more than 3/8” variance between riser heights at deck stairs -install cover plate at TV receptacle deck, GFCI protection required at outlet
Erosion Control Inspection Residential Passed 11/17/2022 11/17/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
11/17/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -maintain gravel filter -clean storm inlet
Piers/Caissons Inspection - Residential Passed 11/17/2022 11/17/2022
Occupancy Inspection - Codes Residential Failed 11/17/2022 11/17/2022 11/17/2022
Misc
Corrective Action Required
11/03/2022
-final sidewalk inspection required, contact development services to schedule -rear slider lock not latching
Sidewalk Inspection Passed 11/17/2022 11/17/2022 11/17/2022
Misc
Informational
11/17/2022
On Thursday, 11-17-2022. I preformed a visual inspection of the existing sidewalk and found it to meet city standards.
Occupancy Inspection - Codes Residential Full C of O 11/18/2022 11/18/2022 11/18/2022
Misc
Resolved
11/18/2022
-final sidewalk inspection required, contact development services to schedule -rear slider lock not latching
Documents & Images
Date Uploaded File Type Document Name
10/11/2021 HT #155 - PERMIT APP
10/11/2021 Approved Plans approved plans
10/11/2021 Approved Plans APPROVED TRUSS LAYOUT
10/11/2021 Approved Plans APPROVED TRUSS PACKAGE
10/11/2021 Plot Plan APPROVED PLOT PLAN
10/12/2021 Permit Codes Residential Plan Review
10/18/2021 Permit DS Building Permit
10/18/2021 Receipt Receipt for transaction:2021-008041
12/10/2021 Letter INSPECTION SUMMARY
12/10/2021 Letter Stop Work Order
12/13/2021 155 Hawthorne Ridge FTNG
12/14/2021 Letter INSPECTION SUMMARY
12/20/2021 Letter INSPECTION SUMMARY
01/18/2022 Letter INSPECTION SUMMARY
01/19/2022 Letter INSPECTION SUMMARY
01/28/2022 Letter INSPECTION SUMMARY
05/17/2022 Letter INSPECTION SUMMARY
05/17/2022 Letter INSPECTION SUMMARY
05/17/2022 Letter INSPECTION SUMMARY
05/17/2022 Letter INSPECTION SUMMARY
05/26/2022 Letter APPROVED TRUSS LETTER
06/01/2022 Letter INSPECTION SUMMARY
06/06/2022 HT 155 2nd Truss Letter
06/07/2022 Letter INSPECTION SUMMARY
06/07/2022 Letter INSPECTION SUMMARY
06/08/2022 Letter INSPECTION SUMMARY
06/09/2022 Receipt Receipt for transaction:2022-004498
06/10/2022 Letter INSPECTION SUMMARY
06/14/2022 Letter INSPECTION SUMMARY
06/14/2022 Letter INSPECTION SUMMARY
08/08/2022 Plot Plan APPROVED AS GRADED PLOT PLAN
08/09/2022 Letter INSPECTION SUMMARY
11/03/2022 Letter INSPECTION SUMMARY
11/17/2022 Letter INSPECTION SUMMARY
11/17/2022 Letter INSPECTION SUMMARY
11/17/2022 Letter INSPECTION SUMMARY
11/17/2022 Letter INSPECTION SUMMARY
11/18/2022 Letter Codes Final Certificate of Occupancy
11/18/2022 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home