PRRES20213815
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSSES - UNFINISHED BASMENT - COVERED DECK STOP WORK ORDER generated on 10/05/2021 12:00 AM by username 'Patrick Schonfeldt'. STOP WORK ORDER removed on 10/14/2021 12:00 AM by username 'Patrick Schonfeldt'.
07/23/2021
08/05/2021
11/08/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331504-EFHB Middle Big Creek, Full $602.64 $602.64 Paid 08/05/2021
8331507-Sewer Connection Fee $540.00 $540.00 Paid 08/05/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 08/05/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 08/05/2021
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 08/05/2021
8350015-Water Meter Fee $479.24 $479.24 Paid 08/05/2021
9110078-Valuation Fee New Single Family $1,322.88 $1,322.88 Paid 08/05/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 10/06/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Failed 10/5/2021 10/5/2021 10/05/2021
Misc
Corrective Action Required
10/05/2021
INSPECTION DENIED FOOTING POURED WITHOUT INSPECTION POST ADDRESS
Footing Inspection - Residential Failed - Stop Work 10/5/2021 10/5/2021 10/05/2021
Misc
Corrective Action Required
10/05/2021
FOOTING POURED WITHOUT INSPECTION - ENGINEER REPORTS REQUIRED TO BE UPLOADED TO PERMIT WITHIN 48 HOURS OF INSPECTION. THIRD PARTY INSPECTION REPORT FOR FOUNDATION ONLY IN PERMIT, NO FOOTING
Footing Inspection - Residential Passed 10/14/2021 10/14/2021 10/14/2021
Misc
Informational
10/14/2021
APPROVED PER BRADLEY HUXOL 8/27/21
Underslab Plumbing Inspection - Residential Passed 10/14/2021 10/14/2021 10/14/2021
Misc
Resolved
10/14/2021
Sewer Service Inspection - R Passed 3/24/2022 (1:00) 3/24/2022 03/24/2022
Water Service Inspection - R Partial 3/24/2022 3/24/2022 03/24/2022
Water Service Inspection - R Passed 3/25/2022 (11:30) 3/25/2022 03/25/2022
Erosion Control Inspection Residential Failed 3/25/2022 3/25/2022 03/25/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
03/25/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Electrical Service Inspection Passed 5/31/2022 5/31/2022 05/31/2022
Gas Service Inspection - Residential Passed 5/31/2022 5/31/2022 05/31/2022
All Rough Inspection - Residential Failed 5/31/2022 5/31/2022 05/31/2022
Misc
Corrective Action Required
05/31/2022
-nail tension straps garage portal -fur down at HVAC garage ceiling to allow for R-19 insulation -solid block between joists above steel beam at garage -fur out garage wall to allow for insulation -address corner lap connection of top plates as required by code see garage walls -address non continuous top plates at different wall heights garage walls -seal all top plate penetrations- see garage -fireblock plumbing fur out garage wall -drop light box at garage ceiling fur down to ceiling height -support DWV every 48” oc, traps not considered support -address floor joist bored for pex and DWV with less than 2” separation at pantry and kitchen, great room -address more than (2) NM wires through same stud/joist penetration, more than (2) NM wires stapled together - see kitchen, entry wall, garage wall -provide gas line casing entry at fireplace per manufacturer installation instructions -provide (2) 2x4 trimmer studs at garage entry per plans -provide bearing for (2) lvl and (4) 2x4 stud pack at great room stair wall per plans -provide (2) 2x10 joist foyer closet per plans -provide (2) 2x10 at deadspace void/great room wall per plans -provide solid blocking all sheathing breaks -install all windows -unable to inspect trusses at covered deck with lid installed -nail off straps at 2x6 to 2x4 top plate lap 2nd floor -provide outlet spacing per code at 2nd floor bedrooms -protect NM within 6’ of attic entry 2nd floor -provide bocca protection plate at DWV top plate master bath and master closet -provide H2.5 truss hold down clips at both plies of dbl girder trusses at bed #2 and master bed -provide (4) 2x4 stud pack at girder truss bearing ends per plans -provide all truss lateral bracing per plans -provide anchor bolts within 12” of plate breaks at basement -address floor joist bored for pex less than 2” from end of joist, west basement above egress window -provide 1” clearance from combustibles at b vent basement -provide 3” SCH 40 steel column at pier location “C” W8x10 steel beam per plans **EXTERIOR NOT INSPECTED AT TIME OF INSPECTION DUE TO WEATHER CONDITIONS, WILL INSPECT AT REINSPECT, CORRECTIONS LIST SUBJECT TO CHANGE**
Erosion Control Inspection Residential Partial 05/31/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
05/31/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
All Rough Inspection - Residential Not Ready 6/9/2022 6/9/2022 06/09/2022
Misc
Corrective Action Required
05/31/2022
-nail tension straps garage portal -fur down at HVAC garage ceiling to allow for R-19 insulation -solid block between joists above steel beam at garage -fur out garage wall to allow for insulation -address corner lap connection of top plates as required by code see garage walls -address non continuous top plates at different wall heights garage walls -seal all top plate penetrations- see garage -fireblock plumbing fur out garage wall -drop light box at garage ceiling fur down to ceiling height -support DWV every 48” oc, traps not considered support -address floor joist bored for pex and DWV with less than 2” separation at pantry and kitchen, great room -address more than (2) NM wires through same stud/joist penetration, more than (2) NM wires stapled together - see kitchen, entry wall, garage wall -provide gas line casing entry at fireplace per manufacturer installation instructions -provide (2) 2x4 trimmer studs at garage entry per plans -provide bearing for (2) lvl and (4) 2x4 stud pack at great room stair wall per plans -provide (2) 2x10 joist foyer closet per plans -provide (2) 2x10 at deadspace void/great room wall per plans -provide solid blocking all sheathing breaks -install all windows -unable to inspect trusses at covered deck with lid installed -nail off straps at 2x6 to 2x4 top plate lap 2nd floor -provide outlet spacing per code at 2nd floor bedrooms -protect NM within 6’ of attic entry 2nd floor -provide bocca protection plate at DWV top plate master bath and master closet -provide H2.5 truss hold down clips at both plies of dbl girder trusses at bed #2 and master bed -provide (4) 2x4 stud pack at girder truss bearing ends per plans -provide all truss lateral bracing per plans -provide anchor bolts within 12” of plate breaks at basement -address floor joist bored for pex less than 2” from end of joist, west basement above egress window -provide 1” clearance from combustibles at b vent basement -provide 3” SCH 40 steel column at pier location “C” W8x10 steel beam per plans **EXTERIOR NOT INSPECTED AT TIME OF INSPECTION DUE TO WEATHER CONDITIONS, WILL INSPECT AT REINSPECT, CORRECTIONS LIST SUBJECT TO CHANGE**
Misc
Corrective Action Required
06/09/2022
Inspection denied not ready -no address posted -both garages locked no access to front stoop
All Rough Inspection - Residential Failed 6/10/2022 6/10/2022 06/10/2022
Misc
Corrective Action Required
06/09/2022
-fur down at HVAC garage ceiling to allow for R-19 insulation -fur out garage wall to allow for insulation -seal all top plate penetrations- see garage -fireblock plumbing fur out garage wall (fire block) -address floor joist bored for pex and DWV with less than 2” separation at kitchen, great room -provide (2) 2x4 trimmer studs at garage entry per plans -covered deck install hangers to plans and code -install windows trim and flashing
Misc
Resolved
06/10/2022
Inspection denied not ready -no address posted -both garages locked no access to front stoop
All Rough Inspection - Residential Failed 6/23/2022 6/23/2022 06/23/2022
Misc
Corrective Action Required
06/10/2022
-covered deck install hangers,lags to plans and code, (PROVIDE MANUFACTURER LISTING THAT SHOWS STRUCTURAL TRUSS SCREWS CAN BE USED FOR LEDGER LAGS) OK TO INSULATE
All Rough Inspection - Residential Passed 6/27/2022 6/27/2022 06/27/2022
Misc
Resolved
06/27/2022
Driveway Inspection Partial 7/20/2022 7/20/2022 07/20/2022
Misc
Informational
07/20/2022
7.20.2022 i conducted a driveway inspection and pass the sub-grade to pour concrete.
Sidewalk Inspection Partial 7/20/2022 7/20/2022 07/20/2022
Misc
Informational
07/20/2022
On 7.20.2022 I conducted a sidewalk inspection and pass the sub-grade to pour concrete.
Driveway Inspection Passed 07/21/2022
Misc
Informational
07/20/2022
7.20.2022 i conducted a driveway inspection and pass the sub-grade to pour concrete. 7.21.2022 Driveway appears to be in compliance.
Sidewalk Inspection Passed 07/21/2022
Misc
Informational
07/20/2022
On 7.20.2022 I conducted a sidewalk inspection and pass the sub-grade to pour concrete. 7.21.2022 Sidewalk appears to be in compliance
Erosion Control Inspection Residential Passed 10/3/2022 10/3/2022 10/03/2022
Plot Plan Inspection Passed 10/3/2022 10/3/2022 10/03/2022
Occupancy Inspection - Codes Residential Failed 10/3/2022 10/3/2022 10/03/2022
Misc
Corrective Action Required
10/03/2022
-resolve outstanding inspection fee -handrail at deck stairs shall terminate above top of bottom rise of flight -(2) 1/2” through bolts each post/beam connection at deck -provide attic ventilation at covered deck -install hardware garage door -garage door must be self closing and latching -install light fixtures 2nd floor bath and bedroom -provide handrail basement stairs -provide guard or wall with rock at bottom flight basement stairs
Occupancy Inspection - Codes Residential Failed 11/1/2022 11/1/2022 11/01/2022
Misc
Corrective Action Required
10/03/2022
-provide guard or wall with rock at bottom flight basement stairs, (PROVIDE SPINDLES OR CLOSE OFF GUARDRAIL, OPENING CANNOT BE LARGER THAN A 4" SPHERE CAN PASS THROUGH)
Occupancy Inspection - Codes Residential Full C of O 11/8/2022 11/8/2022 11/08/2022
Misc
Resolved
11/08/2022
Documents & Images
Date Uploaded File Type Document Name
07/23/2021 MN #128 - PERMIT APP
07/23/2021 Approved Plans APPROVED PLANS
07/23/2021 Approved Plans APPROVED TRUSS DRAWINGS
07/23/2021 Approved Plans APPROVED TRUSS LAYOUT
07/23/2021 Plot Plan APPROVED PLOT PLAN
08/05/2021 Permit Codes Residential Plan Review
08/05/2021 Permit DS Building Permit
08/05/2021 Receipt Receipt for transaction:2021-006250
09/16/2021 Footing inspection
10/05/2021 Letter INSPECTION SUMMARY
10/05/2021 Letter Stop Work Order
10/05/2021 Footing inspection
10/14/2021 128 Manor at Stoney Creek FTNG
10/14/2021 Letter INSPECTION SUMMARY
10/14/2021 Letter INSPECTION SUMMARY
03/24/2022 Letter INSPECTION SUMMARY
03/24/2022 Letter INSPECTION SUMMARY
03/25/2022 Letter INSPECTION SUMMARY
03/25/2022 Letter INSPECTION SUMMARY
05/31/2022 Letter INSPECTION SUMMARY
05/31/2022 Letter INSPECTION SUMMARY
05/31/2022 Letter INSPECTION SUMMARY
05/31/2022 Letter INSPECTION SUMMARY
06/09/2022 128 manor at stoney creek letter
06/09/2022 Letter INSPECTION SUMMARY
06/10/2022 Letter INSPECTION SUMMARY
06/22/2022 2847294 RF LAY 06142022
06/22/2022 BFS D6 Letter
06/23/2022 Letter INSPECTION SUMMARY
06/27/2022 Letter INSPECTION SUMMARY
07/21/2022 Letter INSPECTION SUMMARY
07/21/2022 Letter INSPECTION SUMMARY
07/21/2022 Letter INSPECTION SUMMARY
07/21/2022 Letter INSPECTION SUMMARY
10/03/2022 Letter INSPECTION SUMMARY
10/03/2022 Letter INSPECTION SUMMARY
10/03/2022 Letter INSPECTION SUMMARY
10/06/2022 Receipt Receipt for transaction:2022-008065
11/01/2022 Letter INSPECTION SUMMARY
11/08/2022 Letter Field Certificate of Occupancy
11/08/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home