Permit Application Status

PRRES20212125


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20212125
Building Permit - Residential
Certificate of Occupancy
WINTERSET 6 LLC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK
04/29/2021
04/30/2021
06/24/2022
Locations
Contacts
WINTERSET 6 LLC, Address:2602 N STADIUM BLVD  
SAB CONSTRUCTION INC, Address:PO BOX 942, Phone:(816) 524-3855  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
C-R ELECTRICAL LLC, Address:4539 RIDGEWAY, Phone:(816) 803-3500  
GARRISON PLUMBING, Address:15430 S MAHAFFIE ST STE 102, Phone:(913) 768-1311  
JIM@SABHOMES.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 05/03/2021 04/29/2021
Kim Brennan
Residential Plan Review Approved 05/03/2021 04/29/2021
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,093.10 $1,093.10 Paid 04/30/2021
Right of Way Permit Fee $80.00 $80.00 Paid 04/30/2021
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 04/30/2021
8331507-Sewer Connection Fee $480.00 $480.00 Paid 04/30/2021
Water Tap Fee $3,581.00 $3,581.00 Paid 04/30/2021
Water Meter Fee $455.54 $455.54 Paid 04/30/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 05/26/2021
Underslab Plumbing Inspection - Residential Passed 6/9/2021 6/9/2021 06/09/2021
Piers/Caissons Inspection - Residential Passed 9/10/2021 (8:00) 9/10/2021 09/10/2021
Erosion Control Inspection Residential Failed 11/4/2021 11/04/2021
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
11/04/2021
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Electrical Service Inspection Failed 11/4/2021 11/04/2021
Misc
Corrective Action Required
11/04/2021
Ground to ufer
Gas Service Inspection - Residential Passed 11/4/2021 11/04/2021
All Rough Inspection - Residential Failed 11/4/2021 11/04/2021
Misc
Corrective Action Required
11/04/2021
-Nail the siding to sill plates 6” oc -Nail garage PFH wall sheathing to studs and sill plate @3” oc; install tension straps adjacent to h-frame -Provide full support for for stoop roof beam at garage wall -Strap garage wall top plates lapped less than 24” -Fur out garage wall return air space for R-13 insulation -Fb triangular space at garage door/stair from roof -Provide (3)2x4 support for lvl beam at laundry/garage wall -Install ceiling joist hangers at lvl connections above arch wall opening between mud and living room; install hanger support for 16” lvl connection to the 9.25” header lvl beam. -Joist hangers missing nail at lvl connection near kitchen island -Nail corner studs w/16d @12” oc or equivalent nailing -Provide security blocking for both deck doors 3 stud spaces out or to corner at strike plate height -Provide full support for for ceiling/roof beam at fireplace/master bedroom wall -Brace ends of lvl roof beam from rotation -Vent all bath fans -Fb wall plate penetrations -Install 2 stud support under double 2x12 roof beam at front bedroom -Install (4)2x4 stud support under lvl beam behind stair -Nail hangers at double 2x10 joist connections above stair -Fb basement wall space vertically every ten ft of less; fb top of wall with 3/4” sheathing and Fb gaps; fb wall from horizontal spaces such as fur down ceiling space/soffit/I beam soffit -Anchor basement sill plates per code. Some anchors missing washers&nuts.Tighten all nuts -Seal all penetrations of ceiling joist return air space above both basement bathrooms -Install stud shoe for over bored stud at basement bathroom -Support master bathroom shower drain @ 4 ft or less interval -At rear corner of basement, anchor sill plates within middle 1/3 of sill plates -Install (5)2x4 support for I beams at rear corner basement wall -Provide full support for lvl beam under fireplace -Toe nail all joists to basement wall top plates per code **DO NOT INSULATE
Electrical Service Inspection Passed 11/24/2021 11/24/2021 11/24/2021
Misc
Corrective Action Required
11/04/2021
Ground to ufer
All Rough Inspection - Residential Passed 11/24/2021 11/24/2021 11/24/2021
Misc
Resolved
11/24/2021
Sewer Service Inspection - R Passed 12/8/2021 (1:30) 12/8/2021 12/08/2021
Water Service Inspection - R Passed 12/9/2021 12/09/2021
Erosion Control Inspection Residential Failed 2/9/2022 02/09/2022
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
02/09/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Erosion Control Inspection Residential Failed 2/11/2022 02/11/2022
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
02/09/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.. 2/11/22 8:45 am no change
Driveway Inspection Partial 3/28/2022 3/28/2022 03/28/2022
Misc
Informational
03/28/2022
Forms were placed and aggregate was present and compacted. RP 3-28-22
Driveway Inspection Passed 4/1/2022 4/1/2022 04/01/2022
Misc
Informational
03/28/2022
Forms were placed and aggregate was present and compacted. RP 3-28-22
Misc
Informational
04/01/2022
Finished driveway meets LS specs. RP 4-1-22
Plot Plan Inspection Passed 5/6/2022 05/06/2022
Erosion Control Inspection Residential Passed 5/18/2022 05/18/2022
DCM3 ESC REQUIRED 2 DAY
Resolved
05/18/2022
Occupancy Inspection - Codes Residential Failed 5/18/2022 5/18/2022 05/18/2022
Miscellaneous Correction
Corrective Action Required
05/18/2022
- obtain an irrigation permit - Submit a back flow certification - Back flow preventer in basement and inspected (fyi) - Seal penetration at gas meter - Seal top of meter and A/C disconnect - Label non GFCI outlet in garage - Install back flow device at water main - R507.1(1) 1/2” through bolts required at post to beam connections
Occupancy Inspection - Codes Residential Failed 6/23/2022 6/23/2022 06/23/2022
Miscellaneous Correction
Corrective Action Required
05/18/2022
- Label non GFCI outlet in garage - Install back flow device at water main
Occupancy Inspection - Codes Residential Full C of O 6/24/2022 6/24/2022 06/24/2022
Miscellaneous Correction
Resolved
06/24/2022
Documents & Images
Date Uploaded File Type Document Name
04/29/2021 Application Form Permit Application
04/29/2021 Application Form License Tax Form
04/29/2021 WV1459 - Air Combustion
04/29/2021 Approved Plans Approved Drawings
04/29/2021 Plot Plan Approved Plot Plan
04/30/2021 Receipt Receipt for transaction:2021-002368
04/30/2021 Letter DS Building Permit
05/26/2021 M L Crose 144 NW Carson Dr LSMO Winterset Valley Lot 1459 3rd Party Footing Inspection Report 5-25-21
05/26/2021 Letter INSPECTION SUMMARY
06/09/2021 Letter INSPECTION SUMMARY
09/10/2021 Letter INSPECTION SUMMARY
11/04/2021 Letter INSPECTION SUMMARY
11/04/2021 Letter INSPECTION SUMMARY
11/04/2021 Letter INSPECTION SUMMARY
11/04/2021 Letter INSPECTION SUMMARY
11/24/2021 Letter INSPECTION SUMMARY
11/24/2021 Letter INSPECTION SUMMARY
12/08/2021 Letter INSPECTION SUMMARY
12/09/2021 Letter INSPECTION SUMMARY
02/09/2022 Letter INSPECTION SUMMARY
02/11/2022 Letter INSPECTION SUMMARY
03/28/2022 Letter INSPECTION SUMMARY
04/01/2022 Letter INSPECTION SUMMARY
05/05/2022 Plot Plan Approved As Graded Plot Plan
05/06/2022 Letter INSPECTION SUMMARY
05/18/2022 Letter INSPECTION SUMMARY
05/18/2022 Letter INSPECTION SUMMARY
06/23/2022 Letter INSPECTION SUMMARY
06/24/2022 Letter Codes Final Certificate of Occupancy
06/24/2022 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home