Permit Application Status

PRRES20212003


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20212003
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED PATIO
04/26/2021
08/06/2021
10/23/2021
08/22/2022
Locations
Contacts
SPELLERBERG ENTERPRISES LLC, Address:613 NE VIEWPARK DR, Phone:(816) 550-5535  
AFC HEATING AND COOLING, Address:824 NW MAIN ST , Phone:(816) 347-8388  
NEW HEIGHTS ELECTRIC LLC, Address:P O BOX 163, Phone:(816) 625-9504  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
SPELLERBERGENTERPRISES@GMAIL.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 07/13/2021 07/09/2021
Kim Brennan
Deck location
Corrective Action Required
07/09/2021

Deck location, with dimensions to property lines must be provided on the plot plan. Missing covered patio
Sidewalks
Corrective Action Required
07/09/2021

Sidewalks with dimensions must be provided on the plot plan.
Drainage swales/berms
Corrective Action Required
07/09/2021

Drainage swales/berms: provide cross-section elevations as required to conform to the accepted "As graded" Master Drainge Plan (MDP), include cross-section detail from MDP.
Basement opening elevations
Corrective Action Required
07/09/2021

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan.
As-graded plot plan
Corrective Action Required
07/09/2021

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Residential Plan Review Approved 07/13/2021 07/09/2021
Kim Brennan
Residential Plan Review Approved 04/28/2021 05/06/2021
Kim Brennan
05 Provide square footage of living area, garage area, unfinished basement
Corrective Action Required
04/26/2021

Provide square footage of living area, garage area, unfinished basement area, etc (IRC Section R304) Please provide square footage for covered patio
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
04/26/2021

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315) Please show location for second floor bedroom
21 Foundation wall thickness and height and reinforcement.
Corrective Action Required
04/26/2021

Foundation wall thickness and height and reinforcement. (IRC Section R404)
37 Provide details for any walls over 10 feet in height.
Corrective Action Required
04/26/2021

Provide details for any walls over 10 feet in height. Include stud grade, size, spacing and actual, uninterrupted height. (IRC Section 602.3.1 and Table 602.3(5) & 602.3.1) Does not sepcify uninterrupted height
Planning Review (RES) Approved 04/28/2021 04/26/2021
Kim Brennan
Plot Plan Review Rejected 04/28/2021 04/26/2021
Kim Brennan
Deck location
Corrective Action Required
04/26/2021

Deck location, with dimensions to property lines must be provided on the plot plan. Missing covered patio
Sidewalks
Corrective Action Required
04/26/2021

Sidewalks with dimensions must be provided on the plot plan.
Drainage swales/berms
Corrective Action Required
04/26/2021

Drainage swales/berms: provide cross-section elevations as required to conform to the accepted "As graded" Master Drainge Plan (MDP), include cross-section detail from MDP.
Basement opening elevations
Corrective Action Required
04/26/2021

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan.
As-graded plot plan
Corrective Action Required
04/26/2021

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,365.28 $1,365.28 Paid 08/06/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 08/06/2021
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 08/06/2021
8331507-Sewer Connection Fee $600.00 $600.00 Paid 08/06/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 08/06/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 08/06/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 8/6/2021 (11:00) 8/6/2021 08/06/2021
Sewer Service Inspection - R Passed 9/27/2021 (1:00) 9/27/2021 09/27/2021
Underslab Plumbing Inspection - Residential Passed 9/27/2021 9/27/2021 09/27/2021
Water Service Inspection - R Passed 9/27/2021 (11:30) 9/27/2021 09/27/2021
Piers/Caissons Inspection - Residential Passed 1/14/2022 (8:00) 1/14/2022 01/14/2022
Erosion Control Inspection Residential Partial 3/9/2022 3/9/2022 03/09/2022
Misc
Corrective Action Required
03/09/2022
EROSION CONTROL ACCEPTABLE AT TIME OF INSPECTION
Electrical Service Inspection Failed 3/9/2022 3/9/2022 03/09/2022
Misc
Corrective Action Required
03/09/2022
-replace acorn style clamps GEC to UFER with clamps rated for separation with rebar, acorn clamps installed are for connection to ground rod
Gas Service Inspection - Residential Failed 3/9/2022 3/9/2022 03/09/2022
Misc
Corrective Action Required
03/09/2022
-replace acorn style grounding clamp with clamp rated for rebar **PRESSURE OK**
All Rough Inspection - Residential Failed 3/9/2022 3/9/2022 03/09/2022
Misc
Corrective Action Required
03/09/2022
-address top plate to top plate connection garage wall west side corner -add stud shoe DWV kitchen exterior wall -dbl ceiling joist at sgl car garage per plans -unblock return air above kitchen in joist cavity for 2nd floor -nail exterior sheathing CS-PF at dining room and 2nd floor front bedroom windows per design -header off joists cut at HVAC box out chase dining room, joists supported by non load bearing wall currently, make sure to maintain 1” clearance from b vent in chase to combustibles -provide full bearing support for covered porch beams at front foyer wall -min 24” offset between top plate breaks, strap plate -see 2nd floor bedroom closet -secure all vertical DWV 2” or less at mid point- see 2nd floor -30” vertical clearance required at attic access 2nd floor, relocate HVAC duct off attic access to allow for entry -protect all NM within 6’ of attic access 2nd floor -vent all bath fans to exterior per plans -ensure all purlin struts land on load bearing walls and locations as shown on plans -all purlin struts to be T bracing design -replace acorn style clamps GEC to UFER with clamps rated for separation with rebar, acorn clamps installed are for connection to ground rod -ensure access to UFER at finish basement stair landing
Electrical Service Inspection Passed 3/16/2022 3/16/2022 03/16/2022
Misc
Resolved
03/16/2022
Gas Service Inspection - Residential Passed 3/16/2022 3/16/2022 03/16/2022
Misc
Resolved
03/16/2022
All Rough Inspection - Residential Failed 3/16/2022 3/16/2022 03/16/2022
Misc
Corrective Action Required
03/09/2022
-add stud shoe DWV kitchen exterior wall -secure all vertical DWV 2” or less at mid point- see 2nd floor **OK TO INSULATE**
All Rough Inspection - Residential Passed 3/22/2022 3/22/2022 03/22/2022
Misc
Resolved
03/22/2022
-add stud shoe DWV kitchen exterior wall -secure all vertical DWV 2” or less at mid point- see 2nd floor **OK TO INSULATE**
Driveway Inspection Partial 7/27/2022 7/27/2022 07/27/2022
Misc
Informational
07/27/2022
7-27-22 RH. Driveway forms were up and aggregate was placed and compacted.
Sidewalk Inspection Partial 7/27/2022 7/27/2022 07/27/2022
Misc
Informational
07/27/2022
7-27-22 RH. Sidewalk forms are up and aggregate is placed and compacted.
Driveway Inspection Passed 8/4/2022 8/4/2022 08/04/2022
Misc
Informational
07/27/2022
7-27-22 RH. Driveway forms were up and aggregate was placed and compacted. 8-4-22 RH. Driveway meets ADA and LS Specification.
Sidewalk Inspection Passed 8/4/2022 8/4/2022 08/04/2022
Misc
Informational
07/27/2022
7-27-22 RH. Sidewalk forms are up and aggregate is placed and compacted. 8-4-22 RH. Sidewalk meets LS and ADA specification.
Plot Plan Inspection Passed 8/11/2022 08/11/2022
Erosion Control Inspection Residential Failed 08/12/2022
Misc
Corrective Action Required
03/09/2022
- CLEAN STORM INLET.
Occupancy Inspection - Codes Residential Failed 8/12/2022 8/12/2022 08/12/2022
Miscellaneous Correction
Corrective Action Required
08/12/2022
- Final grading and sod -Splash blocks - Obtain irrigation permit and provide back flow certification - Label all non gfci outlets - Garage entry steps must not have more than 3/8” variance
Erosion Control Inspection Residential Passed 8/22/2022 8/22/2022 08/22/2022
Misc
Resolved
08/22/2022
- CLEAN STORM INLET.
Occupancy Inspection - Codes Residential Full C of O 8/22/2022 8/22/2022 08/22/2022
Miscellaneous Correction
Resolved
08/22/2022
Documents & Images
Date Uploaded File Type Document Name
04/26/2021 Application Form Permit Application and License Tax Form
04/26/2021 Letter Codes Residential Plan Review
05/06/2021 Approved Plans Approved Drawings
07/09/2021 Letter Engeineer Report for lots 1-7,13-29
07/09/2021 Plot Plan Approved Plot Plan
08/06/2021 Permit DS Building Permit
08/06/2021 Receipt Receipt for transaction:2021-006287
08/06/2021 Letter INSPECTION SUMMARY
09/27/2021 Letter INSPECTION SUMMARY
09/27/2021 Letter INSPECTION SUMMARY
09/27/2021 Letter INSPECTION SUMMARY
10/14/2021 528 SE Carter-LSMO-rev1
01/14/2022 Letter INSPECTION SUMMARY
03/09/2022 Letter INSPECTION SUMMARY
03/09/2022 Letter INSPECTION SUMMARY
03/09/2022 Letter INSPECTION SUMMARY
03/09/2022 Letter INSPECTION SUMMARY
03/16/2022 Letter INSPECTION SUMMARY
03/16/2022 Letter INSPECTION SUMMARY
03/16/2022 Letter INSPECTION SUMMARY
03/22/2022 Letter INSPECTION SUMMARY
07/27/2022 Letter INSPECTION SUMMARY
07/27/2022 Letter INSPECTION SUMMARY
08/04/2022 Letter INSPECTION SUMMARY
08/04/2022 Letter INSPECTION SUMMARY
08/10/2022 Plot Plan Approved As Graded Plot Plan
08/11/2022 Letter INSPECTION SUMMARY
08/12/2022 Letter INSPECTION SUMMARY
08/12/2022 Letter INSPECTION SUMMARY
08/12/2022 Letter INSPECTION SUMMARY
08/22/2022 Letter INSPECTION SUMMARY
08/22/2022 Letter Field Certificate of Occupancy
08/22/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home