Permit Application Status

PRRES20211980


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20211980
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - COVERED DECK
04/22/2021
05/13/2021
10/27/2021
04/17/2023
Locations
Contacts
TRUMARK HOMES, LLC, Address:PO BOX 728, Phone:(816) 564-5613  
TRUMARKHOMES.MARK@GMAIL.COM  
C.M. MOSE & SON, Address:6603 ROYAL ST BLDG E, Phone:(816) 781-4707  
IMPACT ELECTRICAL SOLUTIONS LLC, Address:14 ANCHOR DRIVE, Phone:(816) 674-9345  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 05/04/2021 04/30/2021
Brandon Kalwei
Residential Plan Review Approved 05/04/2021 04/30/2021
Brandon Kalwei
05 Provide square footage of living area, garage area, unfinished basement
Corrective Action Required
04/30/2021

Provide square footage of living area, garage area, unfinished basement area, etc (IRC Section R304) cannot locate unfinished basement sq. ft.
07 Identify emergency escape openings from bedrooms
Corrective Action Required
04/30/2021

Identify emergency escape openings from bedrooms and basement(s). (IRC Section R310 as amended per Ordinance) egress windows need to be labeled in basement
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
04/30/2021

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315) smoke/CO detector needs to be labeled outside of bedrooms
10 Combustion air
Corrective Action Required
04/30/2021

Provide combustion air calculations and specify transfer air grilles for fuel burning appliances located in confined space(s). (IRC Chapter 17 and Section G2407)
Misc
Corrective Action Required
04/30/2021

house plans and plot plan layout need to match, currenlty flipped
Plot Plan Review Approved 04/27/2021 04/26/2021
Kim Brennan
Deck location
Corrective Action Required
04/23/2021

Deck location, with dimensions to property lines must be provided on the plot plan. plot plan shows covered patio, needs to be covered deck
Easements
Corrective Action Required
04/23/2021

All easements with dimensions must be provided on the plot plan. no 7.5' easement shown on MDP on west side
Basement opening elevations
Corrective Action Required
04/23/2021

Minimum Building Opening Elevation (MBOE) and location on structure must be provided on the plot plan.
As-graded plot plan
Corrective Action Required
04/23/2021

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Residential Plan Review Rejected 04/27/2021 04/23/2021
Brandon Kalwei
05 Provide square footage of living area, garage area, unfinished basement
Corrective Action Required
04/23/2021

Provide square footage of living area, garage area, unfinished basement area, etc (IRC Section R304) cannot locate unfinished basement sq. ft.
07 Identify emergency escape openings from bedrooms
Corrective Action Required
04/23/2021

Identify emergency escape openings from bedrooms and basement(s). (IRC Section R310 as amended per Ordinance) egress windows need to be labeled in basement
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
04/23/2021

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315) smoke/CO detector needs to be labeled outside of bedrooms
10 Combustion air
Corrective Action Required
04/23/2021

Provide combustion air calculations and specify transfer air grilles for fuel burning appliances located in confined space(s). (IRC Chapter 17 and Section G2407)
Misc
Corrective Action Required
04/23/2021

house plans and plot plan layout need to match, currenlty flipped
Fees
Paid Fees Amount Paid Owing Date Paid
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 05/12/2021
9110078-Valuation Fee New Single Family $945.04 $945.04 Paid 05/12/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 05/12/2021
8331507-Sewer Connection Fee $510.00 $510.00 Paid 05/12/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 05/12/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 05/12/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Failed 5/12/2021 05/12/2021
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
05/12/2021
5-12-21 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -EROSION CONTROL IS REQUIRED AS SOON AS LAND DISTURBANCE BEGINS AND MUST BE MAINTAINED UNTIL FINAL COMPLETION -PROVIDE ADEQUATE EROSION CONTROL AT PERIMETER OF LOT, AROUND STOCKPILES, AND GRAVEL DRIVE WITH 3/4' GRAVEL IN MIN. 6" LIFT -REPLACE OVERGROWN GUTTER BUDDY AT STORM INLET
Footing Inspection - Residential Passed 5/17/2021 5/17/2021 05/17/2021
Misc
Informational
05/17/2021
FOOTING INSPECTION COMPLETED BY DAVID AINSWORTH ON 5-14
Erosion Control Inspection Residential Partial 5/17/2021 5/17/2021 05/17/2021
DCM3 ESC REQUIRED 2 DAY
Resolved
05/17/2021
5-12-21 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -EROSION CONTROL IS REQUIRED AS SOON AS LAND DISTURBANCE BEGINS AND MUST BE MAINTAINED UNTIL FINAL COMPLETION -PROVIDE ADEQUATE EROSION CONTROL AT PERIMETER OF LOT, AROUND STOCKPILES, AND GRAVEL DRIVE WITH 3/4' GRAVEL IN MIN. 6" LIFT -REPLACE OVERGROWN GUTTER BUDDY AT STORM INLET
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
05/17/2021
5-17 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -REPLACE OVERGROWN GUTTER BUDDY AT STORM INLET
Underslab Plumbing Inspection - Residential Passed 6/22/2021 6/22/2021 06/22/2021
Piers/Caissons Inspection - Residential Partial 6/23/2021 (8:00) 6/23/2021 06/23/2021
Misc
Informational
06/23/2021
(1) of (3) 18" piers per plans-corner pier ok
Rough Framing Inspection - Residential Failed 7/23/2021 7/23/2021 07/23/2021
Misc
Corrective Action Required
07/23/2021
-Post address before any further inspections -Solid block sheathing breaks and nail 3" OC per detail -Nail top plate to header with (2) rows 16d sinkers 3" OC per detail -Do not cover
All Rough Inspection - Residential Failed 7/29/2021 07/29/2021
Miscellaneous Correction
Corrective Action Required
07/23/2021
7-23-21 Portal frame inspection: -Post address before any further inspections -Solid block sheathing breaks and nail 3" OC per detail -Nail top plate to header with (2) rows 16d sinkers 3" OC per detail -Do not cover
Miscellaneous Correction
Corrective Action Required
07/29/2021
7-23-21 Portal frame inspection: -Solid block horizontal sheathing breaks at garage wall panel and nail 3" OC per detail -Nail top plate to header with (2) rows 16d sinkers 3" OC per detail -Do not cover
All Rough Inspection - Residential Failed 7/29/2021 07/29/2021
Miscellaneous Correction
Corrective Action Required
07/29/2021
7-23-21 Portal frame inspection: -Post address before any further inspections -Solid block sheathing breaks and nail 3" OC per detail -Nail top plate to header with (2) rows 16d sinkers 3" OC per detail -Do not cover 7-29-21 -Solid block horizontal sheathing breaks at PFH panels and nail 3" OC per detail -Nail top plate to header with (2) rows 16d sinkers 3" OC per detail -Do not cover
Miscellaneous Correction
Corrective Action Required
07/29/2021
Sewer Service Inspection - R Passed 8/19/2021 (8:00) 8/19/2021 08/19/2021
Water Service Inspection - R Passed 8/20/2021 08/20/2021
Erosion Control Inspection Residential Failed 8/23/2021 08/23/2021
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
05/17/2021
*8-23-21 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -RESTORE EROSION CONTROL AT PERIMETER OF LOT, REMOVE TRASH AND DEBRIS FROM SITE
Gas Service Inspection - Residential Failed 9/24/2021 9/24/2021 09/24/2021
G2417.4.1 Test Pressure
Corrective Action Required
09/24/2021
INSPECTION, TESTING AND PURGING. AMENDED 7-945. The test pressure to be used shall be not less than one and one-half times the proposed maximum working pressure, but not less than 10 psig (68.9kPa) irrespective of design pressure. For welded piping, and for piping carrying gas at pressures in excess of fourteen (14) inches water column pressure, the test pressure shall not be less than 60 psig. Where the test pressure exceeds 125 psig (862 kPa gauge), the test pressure shall not exceed a value that produces a hoop stress in the piping greater than 50 percent of the specified minimum yield strength of the pipe.
Miscellaneous Correction
Corrective Action Required
09/24/2021
BOND METALLIC GSS LINE BEFORE FIRST WARD FLEX CONNECTION
Electrical Service Inspection Passed 9/24/2021 9/24/2021 09/24/2021
All Rough Inspection - Residential Failed 9/24/2021 9/24/2021 09/24/2021
Miscellaneous Correction
Corrective Action Required
07/29/2021
7-23-21 Portal frame inspection: -Post address before any further inspections -Solid block sheathing breaks and nail 3" OC per detail -Nail top plate to header with (2) rows 16d sinkers 3" OC per detail -Do not cover 7-29-21 -Solid block horizontal sheathing breaks at PFH panels and nail 3" OC per detail -Nail top plate to header with (2) rows 16d sinkers 3" OC per detail -Do not cover
Miscellaneous Correction
Corrective Action Required
07/29/2021
-Solid block and nail seam at pfh per previous inspections -Complete nailing pattern at pfh -Complete all corrections from failed portal inspection -Ufer at stairwell must remain accessible -Protection plates at nm at garage door -Nail rafter to joist connections per code -Attic access per code -Nail all corners and intersecting walls per code -Provide rafter ties at all rafters not connected to joists at top plate -Provide anchor bolt at end of plate garage East wall -Strap all 2” and smaller dwv at midpoint -Structural straps at top plate bores in load bearing walls to extend 6” each direction of bore with min (4) 8d nails -Solid block and nail sheathing break at master bedroom -Seal gaps in fireblocking at fireplace -Nail bottom plate at fireplace -Rafters at great room over notched -Solid block and nail sheathing seam at entry -Min (3) 2x12 header, straps, nailing at CS-PF locations-See IRC 602.10.6.4 -Clarify bearing for steel beam in great room not on plans -Address beam at garage entry and roof load struts bearing on non load bearing walls -Smoke detector at master -Fireblock furout wall at stairs -Nail joist hangers at stairs -Bocca plate at stair to extend 2” below plate -Insulate and block cantilevers -Solid block point load from above great room to beam -Seal gap at top of furout wall fireblocking -No pressure at gas gauge -Bond gas line before first ward flex connection -Seal penetrations in joist space used as return air bed 2 -Fireblock ceiling line in basement bath -Flash and install egress windows -Solid block joists parallel to foundation per framing notes -Nail sheathing per code -Ledger connection at deck per code -Angle hangers at end joist to ledger/ band connections
All Rough Inspection - Residential Failed 10/21/2021 10/21/2021 10/21/2021
Miscellaneous Correction
Corrective Action Required
09/24/2021
7-23-21 Portal frame inspection: -Post address before any further inspections -Solid block sheathing breaks and nail 3" OC per detail -Nail top plate to header with (2) rows 16d sinkers 3" OC per detail -Do not cover 7-29-21 -Solid block horizontal sheathing breaks at PFH panels and nail 3" OC per detail -Nail top plate to header with (2) rows 16d sinkers 3" OC per detail -Do not cover
Miscellaneous Correction
Corrective Action Required
09/24/2021
-Solid block and nail seam at pfh per previous inspections -Complete nailing pattern at pfh -Complete all corrections from failed portal inspections -Ufer at stairwell must remain accessible -Nail rafter to joist connections per code -Nail all corners and intersecting walls per code -Rafters at great room over notched -Solid block and nail sheathing seam at entry -Min (3) 2x12 header, straps, nailing at CS-PF locations-See IRC 602.10.6.4- Sheathing not nailed at bottom of panels to rim joist per code -Clarify bearing for steel beam in great room not on plans -Smoke detector at master -Nail joist hangers at stairs -Bocca plate at stair to extend 2” below plate -Insulate and block cantilevers -Seal gap at top of furout wall fireblocking - Mechanical room -Pressure at gas gauge below 10 psi -Fireblock ceiling line in basement bath-seal gaps and block east wall at ceiling lline to prevent vertical to horizontal fire spread -Flash and install egress windows -Solid block joists parallel to foundation per framing notes- min (2) joist spaces 48" oc -Nail sheathing per code- west wall and east garage wall -Angle hangers at end joist to ledger/ band connections
Gas Service Inspection - Residential Failed 10/21/2021 10/21/2021 10/21/2021
G2417.4.1 Test Pressure
Corrective Action Required
09/24/2021
INSPECTION, TESTING AND PURGING. AMENDED 7-945. The test pressure to be used shall be not less than one and one-half times the proposed maximum working pressure, but not less than 10 psig (68.9kPa) irrespective of design pressure. For welded piping, and for piping carrying gas at pressures in excess of fourteen (14) inches water column pressure, the test pressure shall not be less than 60 psig. Where the test pressure exceeds 125 psig (862 kPa gauge), the test pressure shall not exceed a value that produces a hoop stress in the piping greater than 50 percent of the specified minimum yield strength of the pipe.
Miscellaneous Correction
Resolved
10/21/2021
BOND METALLIC GSS LINE BEFORE FIRST WARD FLEX CONNECTION
Gas Service Inspection - Residential Passed 10/22/2021 10/22/2021 10/22/2021
G2417.4.1 Test Pressure
Resolved
10/22/2021
INSPECTION, TESTING AND PURGING. AMENDED 7-945. The test pressure to be used shall be not less than one and one-half times the proposed maximum working pressure, but not less than 10 psig (68.9kPa) irrespective of design pressure. For welded piping, and for piping carrying gas at pressures in excess of fourteen (14) inches water column pressure, the test pressure shall not be less than 60 psig. Where the test pressure exceeds 125 psig (862 kPa gauge), the test pressure shall not exceed a value that produces a hoop stress in the piping greater than 50 percent of the specified minimum yield strength of the pipe.
All Rough Inspection - Residential Failed 10/22/2021 10/22/2021 10/22/2021
Miscellaneous Correction
Resolved
10/22/2021
7-23-21 Portal frame inspection: -Post address before any further inspections -Solid block sheathing breaks and nail 3" OC per detail -Nail top plate to header with (2) rows 16d sinkers 3" OC per detail -Do not cover 7-29-21 -Solid block horizontal sheathing breaks at PFH panels and nail 3" OC per detail -Nail top plate to header with (2) rows 16d sinkers 3" OC per detail -Do not cover
Miscellaneous Correction
Corrective Action Required
10/21/2021
Complete deck framing Upload engineered letter to portal for steel beam *OK for sheet rock
Driveway Inspection Passed 10/22/2021 10/22/2021 10/22/2021
Misc
Informational
10/22/2021
On Friday, 10-22-2021, I performed a driveway inspection and passed forming and sub-grade for concrete placement.
Sidewalk Inspection Passed 12/22/2021 12/22/2021 12/22/2021
Misc
Informational
12/22/2021
On Wednesday, 12-22-2021. I performed a sidewalk inspection and passed sidewalk for concrete placement
Occupancy Inspection - Codes Residential Failed 6/8/2022 06/08/2022
Misc
Corrective Action Required
06/08/2022
-upload engineer report to portal concerning steel beam per 10/22/21 all rough inspection report -obtain lawn irrigation system permit -final grade and sod -submit as graded plot plan for review and approval -provide hammer arrestors at washing machine -provide breaker lockouts for hard wired appliance / hot water heater
Plot Plan Inspection Passed 6/22/2022 06/22/2022
Occupancy Inspection - Codes Residential Full C of O 4/17/2023 4/17/2023 04/17/2023
Misc
Resolved
04/17/2023
-upload engineer report to portal concerning steel beam per 10/22/21 all rough inspection report -obtain lawn irrigation system permit -final grade and sod -submit as graded plot plan for review and approval -provide hammer arrestors at washing machine -provide breaker lockouts for hard wired appliance / hot water heater
Documents & Images
Date Uploaded File Type Document Name
04/22/2021 Application Form APPLICATION
04/22/2021 LOT 3 COBEY CREEK SEALED PLANS
04/23/2021 Letter Codes Residential Plan Review
04/26/2021 Plot Plan Approved Plot Plan
04/30/2021 3 COBEY PLOT PLAN
04/30/2021 KYLE I PLANSET REV2 W-DETAILSealed Submittal 4-28-21
04/30/2021 Approved Plans APPROVED PLANS
04/30/2021 Approved Plans APPROVED PLANS
05/12/2021 Letter INSPECTION SUMMARY
05/12/2021 Permit DS Building Permit
05/12/2021 Receipt Receipt for transaction:2021-002972
05/13/2021 Garys Fndn 512 SE David Rd Lee's Summit Mo Colby Creek Lot 3 3rd Party Footing Inspection Report 5-13-21
05/17/2021 Letter INSPECTION SUMMARY
05/17/2021 Letter INSPECTION SUMMARY
06/22/2021 Letter INSPECTION SUMMARY
06/23/2021 Letter INSPECTION SUMMARY
07/23/2021 Letter INSPECTION SUMMARY
07/29/2021 Letter INSPECTION SUMMARY
07/29/2021 Letter INSPECTION SUMMARY
08/19/2021 Letter INSPECTION SUMMARY
08/20/2021 Letter INSPECTION SUMMARY
08/23/2021 Letter INSPECTION SUMMARY
09/24/2021 Letter INSPECTION SUMMARY
09/24/2021 Letter INSPECTION SUMMARY
09/24/2021 Letter INSPECTION SUMMARY
10/21/2021 Letter INSPECTION SUMMARY
10/21/2021 Letter INSPECTION SUMMARY
10/22/2021 Letter INSPECTION SUMMARY
10/22/2021 Letter INSPECTION SUMMARY
10/25/2021 Letter INSPECTION SUMMARY
12/29/2021 Letter INSPECTION SUMMARY
06/08/2022 Letter INSPECTION SUMMARY
06/20/2022 SKM_C36822062015360
06/21/2022 Plot Plan APPROVED AS GRADED PLOT PLAN
06/22/2022 Letter INSPECTION SUMMARY
06/27/2022 Scan_0055
01/26/2023 Letter Codes 180 Day Letter
04/17/2023 Letter Field Certificate of Occupancy
04/17/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide: