NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSSES - FINISHED AND UNFINISHED BASEMENT - COVERED DECK SIDEWALK WILL NOT COVER FRONTAGE OF THE PROPERTY, THE SIDEWALK TERMINATES IN ADA RAMP AT EDGE OF PROPERTY.
04/06/2021
04/07/2021
01/13/2022
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 04/08/2021 04/06/2021
Brandon Kalwei
Residential Plan Review Approved 04/08/2021 04/06/2021
Brandon Kalwei
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $823.85 $823.85 Paid 04/07/2021
8331504-EFHB Middle Big Creek, Full $368.28 $368.28 Paid 04/07/2021
8331507-Sewer Connection Fee $330.00 $330.00 Paid 04/07/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 04/07/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 04/07/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 04/07/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 04/07/2021
9110080-3rd and Subsequent Inspection Fee (Per Hour) $100.00 $100.00 Paid 01/11/2022
9110080-3rd and Subsequent Inspection Fee (Per Hour) $150.00 $150.00 Paid 01/11/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 01/11/2022
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 01/11/2022
Outstanding Fees Amount Paid Owing Date Paid


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 5/10/2021 5/10/2021 05/10/2021
Underslab Plumbing Inspection - Residential Failed 6/7/2021 6/7/2021 06/07/2021
Misc
Corrective Action Required
06/07/2021
-POST ADDRESS -MAINTAIN EROSION CONTROL FRONT OF LOT
Underslab Plumbing Inspection - Residential Passed 6/8/2021 6/8/2021 06/08/2021
Misc
Resolved
06/08/2021
All Rough Inspection - Residential Partial 8/3/2021 8/3/2021 08/03/2021
Misc
Informational
08/03/2021
GARAGE PORTAL EXTERIOR OK TO COVER
Sewer Service Inspection - R Passed 8/26/2021 (1:30) 8/26/2021 08/26/2021
Water Service Inspection - R Partial 8/26/2021 8/26/2021 08/26/2021
Misc
Informational
08/26/2021
PARTIAL INSPECTION ON PEX TO HOUSE ENTRY
Water Service Inspection - R Passed 8/27/2021 (10:15) 8/27/2021 08/27/2021
Misc
Resolved
08/27/2021
Gas Service Inspection - Residential Passed 9/14/2021 9/14/2021 09/14/2021
All Rough Inspection - Residential Not Ready 9/22/2021 9/22/2021 09/22/2021
Misc
Informational
08/03/2021
GARAGE PORTAL EXTERIOR OK TO COVER
Misc
Corrective Action Required
09/22/2021
INSPECTION DENIED NO CITY STAMPED PLANS ON SITE AT INSPECTION
All Rough Inspection - Residential Failed 9/27/2021 9/27/2021 09/27/2021
Misc
Informational
09/22/2021
GARAGE PORTAL EXTERIOR OK TO COVER
Misc
Corrective Action Required
09/22/2021
-Install boot flashing all roof penetrations -seal all top plate penetrations - front entry , pantry, kitchen, hall bath -Bocca protection plate at bottom plate pex master water closet -Nail protection plate at stud for DWV laundry -seal gas flex line floor penetration at fireplace -seal unused bottom plate penetration at kitchen -Nail protection plates at studs for DWV, kitchen/hall bath wall -H2.5 truss hold downs at great room/master bed wall, front bedroom -Exterior wall bracing per design at dining room windows -All truss bracing per plans -Tighten all anchor bolts at basement -Fireblock between top plate and framing throughout at finished basement, seal any gaps around pex,DWV, etc. -Anchor all SCH 40 steel columns to floor at basement -Support DWV every 48” oc, traps not considered support -Shim Jack studs cut short at basement window header -strap top plate basement bedroom, less than 24” offset at dbl top plate break -Nail protection plate at stud, DWV at basement laundry -Underslab DWV waste added for basement laundry? Uncover gravel at cut floor section -Nail protection plates DWV basement bath -Nail all exterior sheathing per plans
Electrical Service Inspection Passed 9/22/2021 09/27/2021
All Rough Inspection - Residential Failed 10/1/2021 10/1/2021 10/01/2021
Misc
Informational
09/27/2021
GARAGE PORTAL EXTERIOR OK TO COVER
Misc
Corrective Action Required
09/27/2021
-seal all top plate penetrations - hall bath -Nail protection plate at stud for DWV laundry - see stud penetration -H2.5 truss hold downs at front bedroom -Exterior wall bracing per design at dining room windows -Fireblock between top plate and framing throughout at finished basement, see north wall at bedroom above egress window -Nail all exterior sheathing per plans
All Rough Inspection - Residential Failed 10/5/2021 10/5/2021 10/05/2021
Misc
Informational
10/01/2021
GARAGE PORTAL EXTERIOR OK TO COVER
Misc
Corrective Action Required
10/01/2021
-Exterior wall bracing per design at dining room windows
All Rough Inspection - Residential Passed 10/6/2021 10/6/2021 10/06/2021
Misc
Resolved
10/06/2021
GARAGE PORTAL EXTERIOR OK TO COVER
Misc
Resolved
10/06/2021
-Exterior wall bracing per design at dining room windows
Driveway Inspection Passed 10/15/2021 10/15/2021 10/15/2021
Misc
Informational
10/15/2021
On 10/15/2021 I performed a driveway inspection and passed the sub-grade to pour concrete. DJ
Occupancy Inspection - Codes Residential Not Ready 12/14/2021 12/14/2021 12/14/2021
Misc
Corrective Action Required
12/14/2021
INSPECTION DENIED POSTED ADDRESS REQUIRED
Erosion Control Inspection Residential Passed 12/16/2021 12/16/2021 12/16/2021
Plot Plan Inspection Failed 12/16/2021 12/16/2021 12/16/2021
Misc
Corrective Action Required
12/16/2021
-SIDEWALK PER APPROVED PLOT PLAN
Occupancy Inspection - Codes Residential Temporary C of O 12/16/2021 12/16/2021 12/16/2021
Misc
Corrective Action Required
12/14/2021
-Resolve outstanding inspection fees before final c of o -sidewalk per approved plot plan -min 6" clearance required between sod and siding - see rear of house -(2) through bolts at each post/beam connection -nail all joist hangers at deck -install angle clips at outer ply of beam at deck OK FOR TCO - TCO EXPIRES 1/17/22
Occupancy Inspection - Codes Residential Failed 12/30/2021 12/30/2021 12/30/2021
Misc
Corrective Action Required
12/16/2021
-Resolve outstanding inspection fees before final c of o -Submit revised plot plan for changes concerning sidewalk at front of property, per Steve Robbins -min 6" clearance required between sod and siding - see rear of house OK FOR TCO - TCO EXPIRES 1/17/22
Occupancy Inspection - Codes Residential Not Ready 1/6/2022 1/6/2022 01/06/2022
Misc
Corrective Action Required
12/30/2021
-Resolve outstanding inspection fees before final c of o -Submit revised plot plan for changes concerning sidewalk at front of property, per Steve Robbins OK FOR TCO - TCO EXPIRES 1/17/22
Plot Plan Inspection Failed 1/11/2022 01/11/2022
Misc
Corrective Action Required
12/16/2021
-SIDEWALK PER APPROVED PLOT PLAN
Misc
Corrective Action Required
01/11/2022
A new plot plan needs to be submitted to show that a sidewalk is not required on this lot.
Plot Plan Inspection Passed 1/13/2022 1/13/2022 01/13/2022
Misc
Resolved
01/13/2022
-SIDEWALK PER APPROVED PLOT PLAN
Misc
Resolved
01/13/2022
A new plot plan needs to be submitted to show that a sidewalk is not required on this lot.
Occupancy Inspection - Codes Residential Full C of O 1/13/2022 1/13/2022 01/13/2022
Misc
Resolved
01/13/2022
Documents & Images
Date Uploaded File Type Document Name
04/06/2021 Application Form APPLICATION
04/06/2021 89 MANOR AT STONEY CREEK ROOF LAYOUT
04/06/2021 MN #89 - Langston - Craftsman - Sheets- signed
04/06/2021 210322
04/06/2021 LOT 89 FINAL
04/06/2021 Approved Plans APPROVED PLANS
04/06/2021 Approved Plans APPROVED TRUSS LAYOUT
04/06/2021 Approved Plans APPROVED TRUSS DRAWINGS
04/07/2021 Receipt Receipt for transaction:2021-001797
04/07/2021 Letter DS Building Permit
05/10/2021 Lot 89 Manor at Stoney Creek footing inspection
05/10/2021 Letter INSPECTION SUMMARY
06/07/2021 Letter INSPECTION SUMMARY
06/08/2021 Letter INSPECTION SUMMARY
08/03/2021 Letter INSPECTION SUMMARY
08/26/2021 Letter INSPECTION SUMMARY
08/26/2021 Letter INSPECTION SUMMARY
08/27/2021 Letter INSPECTION SUMMARY
09/14/2021 Letter INSPECTION SUMMARY
09/22/2021 Letter INSPECTION SUMMARY
09/27/2021 Letter INSPECTION SUMMARY
09/27/2021 Letter INSPECTION SUMMARY
10/01/2021 Letter INSPECTION SUMMARY
10/05/2021 Letter INSPECTION SUMMARY
10/05/2021 89 Manor at Stoney Creek Braced Wall Panel Letter
10/06/2021 Letter INSPECTION SUMMARY
10/06/2021 Letter INSPECTION SUMMARY
10/15/2021 Letter INSPECTION SUMMARY
12/14/2021 Letter INSPECTION SUMMARY
12/16/2021 Letter INSPECTION SUMMARY
12/16/2021 Letter INSPECTION SUMMARY
12/16/2021 Letter Codes Temporary Certificate of Occupancy
12/30/2021 Letter INSPECTION SUMMARY
01/06/2022 Letter INSPECTION SUMMARY
01/11/2022 Receipt Receipt for transaction:2022-000198
01/11/2022 Letter INSPECTION SUMMARY
01/12/2022 Plot Plan APPROVED PLOT PLAN
01/13/2022 Letter INSPECTION SUMMARY
01/13/2022 Letter INSPECTION SUMMARY
01/13/2022 Letter Field Certificate of Occupancy
01/13/2022 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home