Permit Application Status

PRRES20210619


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20210619
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK DEFERRED FLOOR JOISTS
02/16/2021
03/24/2021
08/16/2021
06/14/2022
Locations
Contacts
JFE CONSTRUCTION INC, Address:1314 SW MARKET ST, Phone:(816) 470-0074  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
A BRIGHT PLUMBING LLC, Address:18107 E 18TH TER N, Phone:(816) 215-0730  
CORY@JFECONSTRUCTION.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 03/26/2021 03/24/2021
Kim Brennan
Sidewalks
Corrective Action Required
03/24/2021

Sidewalks with dimensions must be provided on the plot plan.
Residential Plan Review Approved 03/26/2021 03/24/2021
Kim Brennan
07 Identify emergency escape openings from bedrooms
Corrective Action Required
03/24/2021

Identify emergency escape openings from bedrooms and basement(s). (IRC Section R310 as amended per Ordinance)
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
03/24/2021

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315)
10 Combustion air
Corrective Action Required
03/24/2021

Provide combustion air calculations and specify transfer air grilles for fuel burning appliances located in confined space(s). (IRC Chapter 17 and Section G2407)
Misc
Corrective Action Required
03/24/2021

Drawings must be sealed and stamped by a licensed professional in the State of Missouri
12 Detail required separation between garage and living area including door
Corrective Action Required
03/24/2021

Detail required separation between garage and living area including door, door closer and gypsum board. (IRC R302.5) Does not specify 20 minute rated
15 Provide size, spacing, species, and grade of rafter, ceiling joist mater
Corrective Action Required
03/24/2021

Provide size, spacing, species, and grade of rafter, ceiling joist materials and ridge and valley members. (IRC Section R802)
16 Identify location(s) of vertical supports and purlins.
Corrective Action Required
03/24/2021

Identify location(s) of vertical supports and purlins. (IRC Section R802.5.1)
17 Specification of rafter ties or ridge beam design.
Corrective Action Required
03/24/2021

Specification of rafter ties or ridge beam design. (IRC Section 802.3.1)
30 Identify type of protection used in unfinished areas under
Corrective Action Required
03/24/2021

Identify type of protection used in unfinished areas under floor trusses. (IRC Section R501.3)
33 Identify braced wall locations and length of braced wall panel(s).
Corrective Action Required
03/24/2021

Identify braced wall locations and length of braced wall panel(s). (IRC Section R602.10)
34 Specify type of wall bracing method(s) utilized.
Corrective Action Required
03/24/2021

Specify type of wall bracing method(s) utilized. (IRC Section R602.10)
35 Specify acceptable material and size of exterior sheathing.
Corrective Action Required
03/24/2021

Specify acceptable material and size of exterior sheathing. (IRC Section R703)
Plot Plan Review Rejected 02/19/2021 02/17/2021
Kim Brennan
Sidewalks
Corrective Action Required
02/17/2021

Sidewalks with dimensions must be provided on the plot plan.
Residential Plan Review Rejected 02/19/2021 02/17/2021
Kim Brennan
07 Identify emergency escape openings from bedrooms
Corrective Action Required
02/17/2021

Identify emergency escape openings from bedrooms and basement(s). (IRC Section R310 as amended per Ordinance)
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
02/17/2021

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315)
10 Combustion air
Corrective Action Required
02/17/2021

Provide combustion air calculations and specify transfer air grilles for fuel burning appliances located in confined space(s). (IRC Chapter 17 and Section G2407)
Misc
Corrective Action Required
02/17/2021

Drawings must be sealed and stamped by a licensed professional in the State of Missouri
12 Detail required separation between garage and living area including door
Corrective Action Required
02/17/2021

Detail required separation between garage and living area including door, door closer and gypsum board. (IRC R302.5) Does not specify 20 minute rated
15 Provide size, spacing, species, and grade of rafter, ceiling joist mater
Corrective Action Required
02/17/2021

Provide size, spacing, species, and grade of rafter, ceiling joist materials and ridge and valley members. (IRC Section R802)
16 Identify location(s) of vertical supports and purlins.
Corrective Action Required
02/17/2021

Identify location(s) of vertical supports and purlins. (IRC Section R802.5.1)
17 Specification of rafter ties or ridge beam design.
Corrective Action Required
02/17/2021

Specification of rafter ties or ridge beam design. (IRC Section 802.3.1)
30 Identify type of protection used in unfinished areas under
Corrective Action Required
02/17/2021

Identify type of protection used in unfinished areas under floor trusses. (IRC Section R501.3)
33 Identify braced wall locations and length of braced wall panel(s).
Corrective Action Required
02/17/2021

Identify braced wall locations and length of braced wall panel(s). (IRC Section R602.10)
34 Specify type of wall bracing method(s) utilized.
Corrective Action Required
02/17/2021

Specify type of wall bracing method(s) utilized. (IRC Section R602.10)
35 Specify acceptable material and size of exterior sheathing.
Corrective Action Required
02/17/2021

Specify acceptable material and size of exterior sheathing. (IRC Section R703)
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,170.15 $1,170.15 Paid 03/24/2021
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 03/24/2021
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 03/24/2021
8331507-Sewer Connection Fee $510.00 $510.00 Paid 03/24/2021
8350015-Water Meter Fee $455.54 $455.54 Paid 03/24/2021
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 03/24/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 06/14/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 6/1/2021 (8:45) 6/1/2021 06/01/2021
Underslab Plumbing Inspection - Residential Passed 6/10/2021 6/10/2021 06/10/2021
Underslab Electrical Inspection - Residential Passed 06/15/2021
Water Service Inspection - R Passed 6/18/2021 (1:45) 6/18/2021 06/18/2021
Sewer Service Inspection - R Passed 7/13/2021 07/13/2021
All Rough Inspection - Residential Not Ready 8/6/2021 8/6/2021 08/06/2021
Misc
Corrective Action Required
08/06/2021
not ready- straps not nailed over grown vegetation , cut all weeds before next inspection. erosion failed also .
All Rough Inspection - Residential Failed 8/10/2021 8/10/2021 08/10/2021
Misc
Corrective Action Required
08/06/2021
INSPECTION OF GARAGE PORTAL BRACE WALLS FRAMING-OK
Gas Service Inspection - Residential Passed 10/1/2021 10/1/2021 10/01/2021
Electrical Service Inspection Passed 10/1/2021 10/1/2021 10/01/2021
All Rough Inspection - Residential Failed 10/1/2021 10/1/2021 10/01/2021
Misc
Corrective Action Required
08/10/2021
-Strap exterior walls at living room/dining and living room/beam where not connected at top plates -Nail rafter to joist connections at back garage wall -Provide lateral restraint at double LVL both directions at great room and near archway -Strap great room walls at top plate not overlapping at beam near stairs-both sides of wall -Fireblock dead space at fridge -Seal bottom plate penetrations at laundry/ dining wall -Seal upward penetration at laundry by window -Provide proper slope for vent in attic -Provide protection plate for nm at bottom plate near range -Seal through floor penetrations at master vanity and shower drain -Seal top plate penetration at exterior wall in chase at master closet -Protection plate at dwv living room side of bath -(2) king studs at living room windows and front entry per plan -Address living room ridge support-plans show this area to be over framed -Fireblock furout wall at top and end at corner of bed 4 -Vertical fireblocking at 10’ oc at bed 4/ bath -3.5” schedule 40 per plan at bed 4 wall -Provide engineered solution at deck post to beam connections or use post caps and bases where beam is not notched into posts
All Rough Inspection - Residential Failed 10/8/2021 10/8/2021 10/08/2021
Misc
Corrective Action Required
10/01/2021
-Provide engineered solution at deck post to beam connections or use post caps and bases where beam is not notched into posts, see Eng letter ledger locks need to be from post into glulamm at the bottom post, not glulam down into end of post. NW basement room not finished( no ceiling or electrical) inside complete
Driveway Inspection Partial 1/12/2022 1/12/2022 01/12/2022
Misc
Informational
01/12/2022
Forms were placed and aggregate was present and compacted. Contractor has blankets on site to cover and protect the concrete. RP 1-12-22
Sidewalk Inspection Partial 1/12/2022 1/12/2022 01/12/2022
Misc
Corrective Action Required
01/12/2022
Forms were placed and aggregate was present and compacted. Contractor has blankets on site to cover and protect the concrete. Sanitary manhole next to sidewalk will need to be raised to grade to avoid burying the lid. RP 1-12-22
Sidewalk Inspection Passed 1/21/2022 1/21/2022 01/21/2022
Misc
Corrective Action Required
01/12/2022
Forms were placed and aggregate was present and compacted. Contractor has blankets on site to cover and protect the concrete. Sanitary manhole next to sidewalk will need to be raised to grade to avoid burying the lid. RP 1-12-22
Misc
Informational
01/21/2022
Finished sidewalk meets LS and ADA specs. RP 1-21-22
Driveway Inspection Passed 1/21/2022 1/21/2022 01/21/2022
Misc
Informational
01/12/2022
Forms were placed and aggregate was present and compacted. Contractor has blankets on site to cover and protect the concrete. RP 1-12-22
Misc
Informational
01/21/2022
Finished driveway meets LS specs. RP 1-21-22
Piers/Caissons Inspection - Residential Passed 03/10/2022
All Rough Inspection - Residential Passed 3/10/2022 03/10/2022
Misc
Resolved
03/10/2022
-Provide engineered solution at deck post to beam connections or use post caps and bases where beam is not notched into posts, see Eng letter ledger locks need to be from post into glulamm at the bottom post, not glulam down into end of post. NW basement room not finished( no ceiling or electrical) inside complete
Erosion Control Inspection Residential Failed 3/10/2022 03/10/2022
Misc
Corrective Action Required
03/10/2022
repair silt fence maintain until sod is in place.
Deck Final Inspection - Residential Passed 03/10/2022
Occupancy Inspection - Codes Residential Temporary C of O 3/10/2022 3/10/2022 03/10/2022
Misc
Resolved
03/10/2022
Misc
Corrective Action Required
03/10/2022
-submit an asgrade plot plan for patio and retaining wall. -Final grading and sod -provide splash blocks -seal exterior penetrations
Erosion Control Inspection Residential Failed 4/18/2022 04/18/2022
Misc
Corrective Action Required
03/10/2022
repair silt fence maintain until sod is in place.
Piers/Caissons Inspection - Residential Passed 06/14/2022
Miscellaneous Correction
Informational
06/14/2022
house piers aproved by third party.
Plot Plan Inspection Passed 6/14/2022 06/14/2022
Erosion Control Inspection Residential Passed 6/14/2022 06/14/2022
Misc
Resolved
06/14/2022
Occupancy Inspection - Codes Residential Full C of O 6/14/2022 6/14/2022 06/14/2022
Misc
Resolved
06/14/2022
Documents & Images
Date Uploaded File Type Document Name
02/16/2021 Application Form Permit Application
02/16/2021 Application Form License Tax Form
02/17/2021 Letter Codes Residential Plan Review
02/17/2021 Plot Plan Approved Plot Plan
03/08/2021 3010 NW Thoreau Place - Sealed Plans (March 8, 2021)
03/24/2021 Approved Plans Approved Drawings
03/24/2021 Receipt Receipt for transaction:2021-001493
03/24/2021 Letter DS Building Permit
05/07/2021 Approved Plans Approved Pier Plan
05/25/2021 3010 NW Thoreau Pl_PIER INSP_2021-05-24
06/01/2021 Letter INSPECTION SUMMARY
06/10/2021 Letter INSPECTION SUMMARY
06/15/2021 Letter INSPECTION SUMMARY
06/18/2021 Letter INSPECTION SUMMARY
07/09/2021 3010 NW Thoreau Pl_ALL SLAB INSP_2021-07-08
07/13/2021 Letter INSPECTION SUMMARY
08/06/2021 Letter INSPECTION SUMMARY
08/10/2021 Letter INSPECTION SUMMARY
10/01/2021 Letter INSPECTION SUMMARY
10/01/2021 Letter INSPECTION SUMMARY
10/01/2021 Letter INSPECTION SUMMARY
10/08/2021 3010 NW Thoreau Place_Framing Evaluation Report_10-8-21
10/08/2021 Letter INSPECTION SUMMARY
01/12/2022 Letter INSPECTION SUMMARY
01/12/2022 Letter INSPECTION SUMMARY
01/21/2022 Letter INSPECTION SUMMARY
01/21/2022 Letter INSPECTION SUMMARY
03/10/2022 Letter INSPECTION SUMMARY
03/10/2022 Letter INSPECTION SUMMARY
03/10/2022 Letter INSPECTION SUMMARY
03/10/2022 Letter INSPECTION SUMMARY
03/10/2022 Letter Codes Temporary Certificate of Occupancy
04/18/2022 Letter INSPECTION SUMMARY
05/17/2022 Plot Plan Approved As Graded Plot Plan
06/14/2022 Receipt Receipt for transaction:2022-004632
06/14/2022 Letter INSPECTION SUMMARY
06/14/2022 Letter INSPECTION SUMMARY
06/14/2022 Letter INSPECTION SUMMARY
06/14/2022 Letter Codes Final Certificate of Occupancy
06/14/2022 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home