KABELLA EDWARD
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSSES - COVERED PATIO
12/14/2020
12/16/2020
11/24/2021
Locations
Contacts
KABELLA EDWARD, Address:5220 NE MAYBROOK RD  
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
PERMITTING@SUMMITHOMESKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 12/16/2020 12/16/2020
Brandon Kalwei
Residential Plan Review Approved 12/16/2020 12/14/2020
Brandon Kalwei
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,154.14 $1,154.14 Paid 12/16/2020
8331507-Sewer Connection Fee $450.00 $450.00 Paid 12/16/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 12/16/2020
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 12/16/2020
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 12/16/2020
8350015-Water Meter Fee $455.54 $455.54 Paid 12/16/2020
8331504-EFHB Middle Big Creek, Full $502.20 $502.20 Paid 12/16/2020
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 11/12/2021
9110080-3rd and Subsequent Inspection Fee (Per Hour) $50.00 $50.00 Paid 11/12/2021
Outstanding Fees Amount Paid Owing Date Paid
9110080-Not Ready Inspection Fee $50.00 $0.00 $50.00 Not Paid


$50.00    Add Fees to My Cart
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Failed 2/8/2021 2/8/2021 02/08/2021
Miscellaneous Correction
Corrective Action Required
02/08/2021
-Unable to complete inspection of DWV due to snow cover-reschedule when conditions allow for complete inspection -Restore silt fence at front and side of lot
Footing Inspection - Residential Passed 02/22/2021
Underslab Plumbing Inspection - Residential Failed 2/24/2021 2/24/2021 02/24/2021
Miscellaneous Correction
Corrective Action Required
02/08/2021
-UNABLE TO INSPECT ALL DWV DUE TO MUD WATER COVER, PUMP OUT WATER OR WAIT FOR CONDITIONS TO ALLOW -INTERIOR DRAIN TILE RUN DIAGONAL MUST REACH OPPOSITE FOUNDATION FOOTING
Underslab Plumbing Inspection - Residential Passed 3/2/2021 3/2/2021 03/02/2021
Miscellaneous Correction
Resolved
03/02/2021
-UNABLE TO INSPECT ALL DWV DUE TO MUD WATER COVER, PUMP OUT WATER OR WAIT FOR CONDITIONS TO ALLOW -INTERIOR DRAIN TILE RUN DIAGONAL MUST REACH OPPOSITE FOUNDATION FOOTING
All Rough Inspection - Residential Not Ready 5/3/2021 5/3/2021 05/03/2021
Misc
Corrective Action Required
05/03/2021
INSPECTION DENIED -NO CITY APPROVED PLANS ON SITE - -REMOVE ALL STANDING WATER FROM BASEMENT TO ALLOW FOR INSPECTION -
All Rough Inspection - Residential Failed 5/5/2021 5/5/2021 05/05/2021
Misc
Corrective Action Required
05/03/2021
-Fireblock HVAC/DWV chase garage -steel beam at garage requires (4) 2x4 stud pack at bearing, one of the studs cut short at anchor bolt, replace stud -fur down at 2nd floor HVAC ducts in garage ceiling to allow for insulation -trpl joist at garage beam, only (2) of (3) joists supported by beam -Fireblock DWV chase at garage -Secure all vertical DWV 2” or less at mid point -stud shoes at kitchen exterior wall bored for DWV -Nail all joist hangers at lvl living room 1st floor -Joist hangers at 2nd floor stairs landing above front entry 1st floor, 4’ -secure gas flex line at fireplace -seal low volt through floor penetration at fireplace -seal penetration through fireblock and gaps around fireblock at chases living room 1st floor -LIB bracing, all locations per plans -Fireblock between studs at fireplace lid -Jack stud cut short at dining room windows, replace or use an approved shim -H2.5 hold downs at all trusses-covered deck -Nail all abutting and intersecting wall corners 12” oc -strap to connect 2x6 to 2x4 top plates at top 2nd floor stairs -stud missing bed#4 -16”oc per plans -All stud packs at girder truss bearing ends to be (4) 2x4 or (4) 2x6 per plans -seal floor penetrations at HVAC chase master bed -seal top plate penetration master bed/laundry, master bath -Fireblock, seal gap between dbl walls master bed and laundry -anchor all steel columns to floor in basement -Joist hangers at fireplace cantilever basement, over 4’ -Insulate first then solid block at cantilever per plans -Furnace b vent in basement requires 1” clearance, move low volt wires off vent -Address floor joist cut and over notched for DWV -South side basement near egress well -Install basement egress window -Nail exterior sheathing per plans, 6” edge 12” field
All Rough Inspection - Residential Failed 5/20/2021 5/20/2021 05/20/2021
Misc
Corrective Action Required
05/05/2021
-Fireblock HVAC/DWV chase garage-seal gaps at entry wall side -fur down at 2nd floor HVAC ducts in garage ceiling to allow for insulation-lower electrical to finish height Yeah -trpl joist at garage beam, only (2) of (3) joists supported by beam-untreated wood in contact with concrete -Fireblock DWV chase at garage-seal gaps -Secure all vertical DWV 2” or less at mid point -stud shoes at kitchen exterior wall bored for DWV- provide proper size or engineered correction -seal penetration through fireblock and gaps around fireblock at chases living room 1st floor -strap to connect 2x6 to 2x4 top plates at top 2nd floor stairs-exterior walls -Nail exterior sheathing per plans, 6” edge 12” field
All Rough Inspection - Residential Passed 6/3/2021 6/3/2021 06/03/2021
Misc
Resolved
06/03/2021
Sewer Service Inspection - R Passed 8/17/2021 (10:30) 8/17/2021 08/17/2021
Water Service Inspection - R Partial 8/17/2021 08/17/2021
Misc
Informational
08/17/2021
PARTIAL INSPECTION ON PEX
Water Service Inspection - R Passed 8/19/2021 (1:00) 8/19/2021 08/19/2021
Misc
Resolved
08/19/2021
Driveway Inspection Passed 9/9/2021 09/09/2021
Electrical Service Inspection Passed 9/10/2021 9/10/2021 09/10/2021
Gas Service Inspection - Residential Passed 9/10/2021 9/10/2021 09/10/2021
Occupancy Inspection - Codes Residential Failed 10/27/2021 10/27/2021 10/27/2021
Misc
Resolved
10/27/2021
Resolved
10/27/2021
Misc
Corrective Action Required
10/27/2021
-security screws at front door hinges/missing screws -splash blocks for down spouts and sump pump extension 36” from foundation -seal top of meter can, A/c disconnect, & all other exterior penetrations -anti tip device on oven -label all non GFCI outlets in unfinished spaces -all outlets in garage space not currently working -smoke/carbon dioxide detectors not all ran together -guard rail at front stoop as required by section R312.1.1
Occupancy Inspection - Codes Residential Failed 10/27/2021 10/27/2021 10/27/2021
Misc
Corrective Action Required
10/27/2021
*PAY ALL FEES* -security screws at front door hinges/missing screws -splash blocks for down spouts and sump pump extension 36” from foundation -seal top of meter can, A/c disconnect, & all other exterior penetrations -anti tip device on oven -label all non GFCI outlets in unfinished spaces -all outlets in garage space not currently working -smoke/carbon dioxide detectors not all ran together -guard rail at front stoop as required by section R312.1.1 -meter must be 14”-18” from meter lid to well lid. -obtain sprinkler permit
Occupancy Inspection - Codes Residential Failed 11/12/2021 11/12/2021 11/12/2021
Misc
Corrective Action Required
10/27/2021
*PAY ALL FEES* -anti tip device on oven -smoke/carbon dioxide detectors not all ran together -guard rail at front stoop as required by section R312.1.1 -obtain sprinkler permit Mitchell Schwarz 11/12/2021 9:05 AM
Occupancy Inspection - Codes Residential Not Ready 11/24/2021 11/24/2021 11/24/2021
Misc
Corrective Action Required
11/12/2021
*PAY ALL FEES* -smoke/carbon dioxide detectors not all ran together Mitchell Schwarz 11/24/2021 9:27 AM
Occupancy Inspection - Codes Residential Full C of O 11/24/2021 11/24/2021
Misc
Corrective Action Required
11/24/2021
Documents & Images
Date Uploaded File Type Document Name
12/14/2020 Application Form APPLICATION
12/14/2020 Approved Plans APPROVED PLANS
12/14/2020 Approved Plans APPROVED TRUSS DRAWINGS
12/14/2020 Approved Plans APPROVED TRUSS DRAWINGS
12/16/2020 Plot Plan APPROVED PLOT PLAN
12/16/2020 Receipt Receipt for transaction:2020-008034
12/16/2020 Letter DS Building Permit
01/21/2021 MN83 Footing Inspection
02/08/2021 Letter INSPECTION SUMMARY
02/22/2021 Letter INSPECTION SUMMARY
02/24/2021 Letter INSPECTION SUMMARY
03/02/2021 Letter INSPECTION SUMMARY
05/03/2021 Letter INSPECTION SUMMARY
05/05/2021 Letter INSPECTION SUMMARY
05/20/2021 Letter INSPECTION SUMMARY
06/03/2021 Letter INSPECTION SUMMARY
08/17/2021 Letter INSPECTION SUMMARY
08/17/2021 Letter INSPECTION SUMMARY
08/19/2021 Letter INSPECTION SUMMARY
09/09/2021 Letter INSPECTION SUMMARY
09/10/2021 Letter INSPECTION SUMMARY
09/10/2021 Letter INSPECTION SUMMARY
10/27/2021 Letter INSPECTION SUMMARY
11/08/2021 Letter INSPECTION SUMMARY
11/12/2021 Receipt Receipt for transaction:2021-008723
11/24/2021 Letter INSPECTION SUMMARY
11/24/2021 Letter Codes Final Certificate of Occupancy
11/24/2021 Letter Field Certificate of Occupancy
12/13/2021 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home