Summary
PRRES20204535
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSSES - COVERED DECK - FINISHED AND UNFINISHED BASEMENT
12/01/2020
12/18/2020
11/15/2021
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
PERMITTING@SUMMITHOMESKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Planning Review (RES) Approved 12/17/2020 12/17/2020
Shannon McGuire
Plot Plan Review Approved 12/11/2020 12/17/2020
Brandon Kalwei
Residential Plan Review Approved 12/11/2020 12/09/2020
Brandon Kalwei
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $995.24 $995.24 Paid 12/18/2020
8331507-Sewer Connection Fee $360.00 $360.00 Paid 12/18/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 12/18/2020
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 12/18/2020
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 12/18/2020
8350015-Water Meter Fee $455.54 $455.54 Paid 12/18/2020
9110078-Additional Permit Fee $97.72 $97.72 Paid 02/08/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 10/07/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 10/07/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 10/07/2021
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 11/10/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Piers/Caissons Inspection - Residential Failed 1/28/2021 01/28/2021
Misc
Resolved
07/07/2021
- H 2X 16 X 36 W/ (4) #4 VERT BARS - - K 1X 24 X 36 W/ (4) #4 VERT BARS
Footing Inspection - Residential Partial 1/28/2021 (2:00) 1/28/2021 01/28/2021
Misc
Partial Correction
01/28/2021
- SEND ENGINEERS SOIL REPORT & HELIX OPTION TO DEV TECH TO UPLOAD TO PERMIT - - - HELIX OPTION SHEET IS TYPICAL DETAIL DOES NOT HAVE ADDRESS OR LOT # - - OK TO POUR FOOTING ONLY NO PIERS -
Water Service Inspection - R Passed 2/25/2021 (11:00) 2/25/2021 02/25/2021
Misc
Partial Correction
02/25/2021
- PROVIDE ADDRESS -
Sewer Service Inspection - R Passed 2/25/2021 (1:15) 2/25/2021 02/25/2021
Erosion Control Inspection Residential Failed 3/25/2021 03/25/2021
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
03/25/2021
- MAINTAIN SILT FENCE - REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
Underslab Plumbing Inspection - Residential Not Ready 3/25/2021 3/25/2021 03/25/2021
R506.2.5 Interior Underslab Drains
Corrective Action Required
03/25/2021
- COMPLETE INTERIOR DRAIN TILE - CONCRETE FLOORS (ON GROUND). ADDED 7-927. Where foundations retain earth and enclose habitable or usable space located below grade, drains shall be provided below the floor slab. Drainage tiles, perforated pipe or other approved systems or materials shall be installed at or below the area(s) to be protected; shall be placed with positive or neutral slope to minimize the accumulation of deposits in the drainage system; and shall discharge by gravity or mechanical means to an approved storm water drainage system. The underslab drainage system shall be installed around the inner perimeter of the area(s) to be protected, or, in a manner that will provide adequate drainage for all area(s) to be protected and is approved by the building official. Interior underslab drains installed on uncompacted fill material shall be supported by mechanical means which are adequately tied into the concrete slab to ensure proper drainage throughout the underslab drain(s).
Underslab Plumbing Inspection - Residential Passed 4/1/2021 4/1/2021 04/01/2021
R506.2.5 Interior Underslab Drains
Resolved
04/01/2021
- COMPLETE INTERIOR DRAIN TILE - CONCRETE FLOORS (ON GROUND). ADDED 7-927. Where foundations retain earth and enclose habitable or usable space located below grade, drains shall be provided below the floor slab. Drainage tiles, perforated pipe or other approved systems or materials shall be installed at or below the area(s) to be protected; shall be placed with positive or neutral slope to minimize the accumulation of deposits in the drainage system; and shall discharge by gravity or mechanical means to an approved storm water drainage system. The underslab drainage system shall be installed around the inner perimeter of the area(s) to be protected, or, in a manner that will provide adequate drainage for all area(s) to be protected and is approved by the building official. Interior underslab drains installed on uncompacted fill material shall be supported by mechanical means which are adequately tied into the concrete slab to ensure proper drainage throughout the underslab drain(s).
Footing Inspection - Residential Passed 4/2/2021 04/02/2021
Misc
Partial Correction
01/28/2021
- OK TO POUR FOOTING ONLY NO PIERS -
All Rough Inspection - Residential Failed 5/26/2021 5/26/2021 05/26/2021
Miscellaneous Correction
Corrective Action Required
05/26/2021
PFH: -COMPLETE NAILING PATTERN AT HEADER -NAIL INTERIOR TENSION STRAPS -MISSING NUTS/ WASHER AT ANCHOR BOLTS -PROVIDE 2 ROWS 16d SINKERS 3” OC AT HEADER TO TOP PLATE PER DETAIL DECK: -UNCOVER BEAMS/ COLUMS AND ALL CONNECTIONS FOR INSPECTION
Electrical Service Inspection Passed 7/7/2021 07/07/2021
Gas Service Inspection - Residential Passed 7/7/2021 07/07/2021
Piers/Caissons Inspection - Residential Passed 2/25/2021 07/07/2021
Erosion Control Inspection Residential Failed 7/7/2021 07/07/2021
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
03/25/2021
- MAINTAIN SILT FENCE - REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
07/07/2021
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE - - MAINTAIN GRAVEL FILTER - -- CLEAN STREET -
All Rough Inspection - Residential Failed 7/7/2021 7/7/2021 07/07/2021
Miscellaneous Correction
Corrective Action Required
05/26/2021
PFH: -COMPLETE NAILING PATTERN AT HEADER -PROVIDE 2 ROWS 16d SINKERS 3” OC AT HEADER TO TOP PLATE PER DETAIL DECK: -UNCOVER BEAMS/ COLUMS AND ALL CONNECTIONS FOR INSPECTION
Miscellaneous Correction
Corrective Action Required
07/07/2021
Provide 4 studs at girder truss bearing points per roof plan Sheet A5.0 Anchor bolts shall be in middle 1/3 the width of plate Provide anchor bolts within 12" of plate break garage Tighten anchor bolts garage Nail sheathing throughout per code / per plan sheet S1.0 Provide H2.5 or Trusslock screws above garage doors, girder above SGD, Provide CF PF nailing & straps great room window Provide LIBs per plan Provide hangers truss E1 bed #3 Fire block dead space laundry Frame door opening hall bath Nail hangers above door under stairs Tighten anchor bolts basement Provide anchor bolts within 12" of plate break & end of plates basement Provide anchor bolts SCH 40 columns Anchor bolt near sliding glass door missing nut & washer Fire block dead space near SGD basement in Fire block east wall top plate to roof deck
Erosion Control Inspection Residential Failed 7/15/2021 07/15/2021
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
07/07/2021
- MAINTAIN SILT FENCE - REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
07/15/2021
- MAINTAIN SILT FENCE - - CLEAN STREET - DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
All Rough Inspection - Residential Not Ready 7/15/2021 7/15/2021 07/15/2021
Miscellaneous Correction
Resolved
07/15/2021
PFH: OK TO COVER DECK: OK TO COVER
Miscellaneous Correction
Corrective Action Required
07/07/2021
Nail sheathing throughout per code / per plan sheet S1.0 (! East garage wall, bed #2, great room ) Provide CF PF nailing great room window Fire block dead space laundry ( seal gaps ) Fire block dead space near SGD basement (!seal at DWV) Fire block east wall top plate to roof deck ( seal gaps : DO NOT INSULATE :
All Rough Inspection - Residential Passed 7/21/2021 7/21/2021 07/21/2021
Miscellaneous Correction
Resolved
07/21/2021
Nail sheathing throughout per code / per plan sheet S1.0 (! East garage wall, bed #2, great room ) Provide CF PF nailing great room window Fire block dead space laundry ( seal gaps ) : DO NOT INSULATE :
Driveway Inspection Partial 8/3/2021 08/03/2021
Misc
Informational
08/03/2021
Forms were placed and aggregate was present and compacted. RP 8-3-21
Driveway Inspection Passed 8/6/2021 8/6/2021 08/06/2021
Misc
Informational
08/03/2021
Forms were placed and aggregate was present and compacted. RP 8-3-21
Misc
Informational
08/06/2021
Finished driveway meets LS and ADA specs. RP 8-6-21
Sidewalk Inspection Not Ready 9/16/2021 9/16/2021 09/16/2021
Misc
Corrective Action Required
09/16/2021
No aggregate in place
Sidewalk Inspection Partial 9/17/2021 9/17/2021 09/17/2021
Misc
Corrective Action Required
09/16/2021
No aggregate in place
Misc
Informational
09/17/2021
Forms were placed and aggregate was present and compacted. Notified Summit Homes about broken mailbox pad. RP 9-17-21
Sidewalk Inspection Failed 9/24/2021 9/24/2021 09/24/2021
Misc
Corrective Action Required
09/17/2021
No aggregate in place
Misc
Informational
09/17/2021
Forms were placed and aggregate was present and compacted. Notified Summit Homes about broken mailbox pad. RP 9-17-21
Misc
Informational
09/24/2021
9-24-21 11:50. Sidewalk is good and meets ADA spec of 1.5% or less. Expansion joint on east side of house snagged my foot and needs to be cut.
Occupancy Inspection - Codes Residential Failed 10/11/2021 10/11/2021 10/11/2021
Miscellaneous Correction
Corrective Action Required
10/11/2021
Provide address of contrasting color of trim Obtain irrigation permit and submit backflow results Sidewalk inspection pending Provide final grade & sod & splash blocks Provide switch cover plate near SGD Complete spinals stairway to basement Provide back-flow device at water shut off near water heater Provide deck beam to post connection SE post Remove paper from insulation unfinished basement spaces or cover with approved retardant Provide deadbolt front door Seal top of exterior light fixtures
Occupancy Inspection - Codes Residential Temporary C of O 10/15/2021 10/15/2021 10/15/2021
Miscellaneous Correction
Corrective Action Required
10/11/2021
Obtain irrigation permit and submit backflow results Sidewalk inspection pending Provide final grade & sod & splash blocks Provide deck beam to post connection SE post
Occupancy Inspection - Codes Residential Not Ready 11/10/2021 11/10/2021 11/10/2021
Miscellaneous Correction
Corrective Action Required
10/15/2021
Obtain irrigation permit and submit backflow results Provide deck beam to post connection SE post
Occupancy Inspection - Codes Residential Full C of O 11/15/2021 11/15/2021 11/15/2021
Miscellaneous Correction
Resolved
11/15/2021
Documents & Images
Date Uploaded File Type Document Name
12/01/2020 Application Form APPLICATION
12/17/2020 Approved Plans APPROVED TRUSS LAYOUT
12/17/2020 Application Form APPROVED PLANS
12/17/2020 Approved Plans APPROVED TRUSS DRAWINGS
12/17/2020 Plot Plan APPROVED PLOT PLAN
12/18/2020 Receipt Receipt for transaction:2020-008115
12/18/2020 Letter DS Building Permit
01/28/2021 Letter INSPECTION SUMMARY
01/28/2021 Letter INSPECTION SUMMARY
02/08/2021 Scope of Work Statement Application
02/08/2021 W1 #15 - Basement Finish A3 REVISION- signed
02/08/2021 Approved Plans APPROVED BASEMENT FINISH
02/08/2021 Receipt Receipt for transaction:2021-000615
02/25/2021 Letter INSPECTION SUMMARY
02/25/2021 Letter INSPECTION SUMMARY
03/25/2021 Letter INSPECTION SUMMARY
03/25/2021 Letter INSPECTION SUMMARY
03/25/2021 Letter INSPECTION SUMMARY
03/25/2021 Letter INSPECTION SUMMARY
04/01/2021 Letter INSPECTION SUMMARY
04/02/2021 W1-15 Woodside Ridge Subgrade
04/02/2021 Letter INSPECTION SUMMARY
05/26/2021 Letter INSPECTION SUMMARY
07/07/2021 Letter INSPECTION SUMMARY
07/07/2021 Letter INSPECTION SUMMARY
07/07/2021 Letter INSPECTION SUMMARY
07/07/2021 Letter INSPECTION SUMMARY
07/07/2021 Letter INSPECTION SUMMARY
07/15/2021 Letter INSPECTION SUMMARY
07/15/2021 Letter INSPECTION SUMMARY
07/21/2021 Letter INSPECTION SUMMARY
08/03/2021 Letter INSPECTION SUMMARY
08/06/2021 Letter INSPECTION SUMMARY
09/16/2021 Letter INSPECTION SUMMARY
09/17/2021 Letter INSPECTION SUMMARY
09/24/2021 Letter INSPECTION SUMMARY
10/07/2021 Receipt Receipt for transaction:2021-007839
10/11/2021 Letter INSPECTION SUMMARY
10/15/2021 Letter Codes Temporary Certificate of Occupancy
11/10/2021 Letter INSPECTION SUMMARY
11/10/2021 Receipt Receipt for transaction:2021-008658
11/15/2021 Letter Codes Final Certificate of Occupancy
11/15/2021 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents