Permit Application Status

PRRES20203433


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20203433
Building Permit - Residential
Expired
BRESNAHAN VINCENT D & VICTORIA C
NEW OTHER (RESIDENTIAL)
INGROUND POOL AND PATIO
09/30/2020
10/20/2020
Locations
Contacts
BRESNAHAN VINCENT D & VICTORIA C, Address:1721 NE WOODLAND SHORES LN  
PRECISION POOLS & PATIOS INC, Address:P O BOX 6885, Phone:(816) 875-5560  
KYLEYEO@SBCGLOBAL.NET  
THE SOLAR GUYS, Address:6114 MO-9 HWY STE C1, Phone:(913) 424-2112  
Reviews
Review Type Outcome Est. Completion Date Completed
Licensed Contractors Approved 09/30/2020 10/19/2020
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee for New Other $360.00 $360.00 Paid 10/20/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Pool Final - Residential Pending
Pool Steel/Bonding - Residential Pending
Misc
Partial Correction
04/06/2021
POOL COMPONENTS BONDED: POOL SHELL WITH JUMPERS TO BOND PERIMETER, PERIMETER BOND, JUMPER TO EQUIPMENT PAD **THE POOL WATER BONDING DEVICE IS INSTALLED INSIDE THE SKIMMER, BUT THE BONDING CONNECTION TO THE POOL SHELL CANNOT BE VERIFIED. THERE IS NO VISUAL INDICATION THAT IT IS BONDED TO THE PERIMETER REBAR OR BONDING LOOP. I TALKED TO THE HOME OWNER, AND SHE SAID THAT THE POOL BUILDER TOLD HER THAT THE DEVICE INSIDE THE SKIMMER IS BONDED. **PROVIDE A SIGNED LETTER CONFIRMING THE BONDING OF THE POOL WATER BONDONG DEVICE TO THE POOL SHELL OR PERIMETER
Pool Steel/Bonding - Residential Partial 10/21/2020 10/21/2020 10/21/2020
Misc
Partial Correction
10/21/2020
POOL COMPONENTS BONDED: POOL SHELL WITH JUMPERS TO BOND PERIMETER
Pool Steel/Bonding - Residential Failed 3/25/2021 3/25/2021 03/25/2021
Misc
Partial Correction
10/21/2020
POOL COMPONENTS BONDED: POOL SHELL WITH JUMPERS TO BOND PERIMETER **NOT READY. BOND THE POOL SHELL TO THE DECK REBAR WITH LISTED REBAR CLAMPS, BOND THE POOL WATER WITH LISTED DEVICE W/ MIN 9 SQ INCHES OF CONTACT WITH WATER AT ALL TIME, RUN A BONDING JUMPER TO EQUIPMENTS LOCATION, BOND THE PERIMETER WHERE THERE IS NO DECK WITH #8 SOLID CU CONDUCTOR LOCATED 18"-24" FROM INSIDE POOL WALL AND 4"-6" BELOW SOIL
Pool Steel/Bonding - Residential Failed 3/31/2021 03/31/2021
Misc
Partial Correction
03/25/2021
POOL COMPONENTS BONDED: POOL SHELL WITH JUMPERS TO BOND PERIMETER, PERIMETER BOND, JUMPER TO EQUIPMENT PAD **NOT READY. PROVIDE BONDING JUMPER FROM DEVICE IN SKIMMER TO PERIMETER BONDING AND CONNECT WITH LISTED CLAMP-DEVICE IS CURRENTLY NOT CONNECTED TO REST OF BONDING
Pool Steel/Bonding - Residential Partial 4/6/2021 4/6/2021 04/06/2021
Misc
Partial Correction
03/31/2021
POOL COMPONENTS BONDED: POOL SHELL WITH JUMPERS TO BOND PERIMETER, PERIMETER BOND, JUMPER TO EQUIPMENT PAD **THE POOL WATER BONDING DEVICE IS INSTALLED INSIDE THE SKIMMER, BUT THE BONDING CONNECTION TO THE POOL SHELL CANNOT BE VERIFIED. THERE IS NO VISUAL INDICATION THAT IT IS BONDED TO THE PERIMETER REBAR OR BONDING LOOP. I TALKED TO THE HOME OWNER, AND SHE SAID THAT THE POOL BUILDER TOLD HER THAT THE DEVICE INSIDE THE SKIMMER IS BONDED. **PROVIDE A SIGNED LETTER CONFIRMING THE BONDING OF THE POOL WATER BONDONG DEVICE TO THE POOL SHELL OR PERIMETER
Documents & Images
Date Uploaded File Type Document Name
09/30/2020 APPROVED INGROUND POOL
10/20/2020 Receipt Receipt for transaction:2020-007051
10/20/2020 Letter DS Building Permit
10/21/2020 Letter INSPECTION SUMMARY
03/10/2021 Letter Codes 140 Day Letter
03/25/2021 Letter Codes 140 Day Letter
03/25/2021 Letter INSPECTION SUMMARY
03/25/2021 Letter INSPECTION SUMMARY
03/25/2021 Letter INSPECTION SUMMARY
03/31/2021 Letter INSPECTION SUMMARY
04/06/2021 Letter INSPECTION SUMMARY
01/11/2022 Letter Codes 180 Day Letter
01/11/2022 Letter Codes 180 Day Letter
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home