Permit Application Status

PRRES20202544


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20202544
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSS - UNFINISHED BASEMENT
08/25/2020
09/04/2020
06/23/2021
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 08/27/2020 08/26/2020
Dylan Eppert
Residential Plan Review Approved 08/27/2020 08/26/2020
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,404.56 $1,404.56 Paid 09/04/2020
8331504-EFHB Middle Big Creek, Full $669.60 $669.60 Paid 09/04/2020
8331507-Sewer Connection Fee $600.00 $600.00 Paid 09/04/2020
8331401-Water Tap Fee $3,581.00 $3,581.00 Paid 09/04/2020
8350015-Water Meter Fee $455.54 $455.54 Paid 09/04/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 09/04/2020
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 09/04/2020
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 06/16/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 10/5/2020 (1:00) 10/5/2020 10/05/2020
Underslab Plumbing Inspection - Residential Not Ready 10/29/2020 10/29/2020 10/29/2020
Misc
Corrective Action Required
10/29/2020
INSPECTION DENIED - POST ADDRESS - EROSION CONTROL REQUIRED AT FRONT OF LOT, MAINTAIN SILT FENCE - CLEAN MUD AND GRAVEL IN STREET AT FRONT OF LOT
Erosion Control Inspection Residential Failed 10/29/2020 10/29/2020 10/29/2020
Misc
Corrective Action Required
10/29/2020
- EROSION CONTROL REQUIRED AT FRONT OF LOT, MAINTAIN SILT FENCE - CLEAN MUD AND GRAVEL IN STREET AT FRONT OF LOT
Underslab Plumbing Inspection - Residential Passed 11/3/2020 11/3/2020 11/03/2020
Misc
Resolved
11/03/2020
Piers/Caissons Inspection - Residential Passed 1/4/2021 (10:45) 1/4/2021 01/04/2021
Sewer Service Inspection - R Passed 1/19/2021 01/19/2021
Electrical Service Inspection Passed 1/19/2021 01/19/2021
Gas Piping Inspection - Residential Failed 1/19/2021 01/19/2021
Misc
Corrective Action Required
01/19/2021
Pressure test gas piping minimum 10 psi for 15 minutes
Gas Service Inspection - Residential Failed 1/19/2021 01/19/2021
All Rough Inspection - Residential Failed 1/19/2021 1/19/2021 01/19/2021
Misc
Corrective Action Required
01/19/2021
-Tighten all anchor bolts in garage -Two rows of 16D sinker nails 3” oc at portal opening top plate per plan, see section view of detail -Properly fireblock soffit to wall connection, garage/dwelling separation wall -Minimum 20A circuits in garage -Address field cut engineered truss in garage -Midpoint support for all vertical 2 inch and smaller DWV -Provide nail plate protection at conductor stud penetrations at marked locations -Fireblock top plate penetration, garage -Provide nail plate protection, DWV top plate penetration kitchen -Fireblock vertical to horizontal, chase to soffit in living room -Provide minimum 16g galvanized metal ties 1.5” wide at over bored top plates of interior load bearing walls. Fasten ties across and to the plate at each side of the opening with minimum 4-10dx1.5” at each side. The metal tie must extend a minimum of 6” past the opening. See figure R602.6.1 -Provide joist hanger, second floor framing at entry -Properly fasten double joist hanger, second floor framing above living room -Properly fastened stud shoes, kitchen DWV -12” oc fastening, stud to stud and abutting studs at intersecting braced walls -Pressure test gas piping, minimum 10psi for 15 minutes -Anchor bolt required within 12 inches a bottom plate splice, basement right of egress window -Properly fireblock all through floor penetrations -Maximum 16 inch OC stud spacing for Interior brace wall method LIB -Provide nail plate protection for Conductor top plate penetrations in master bedroom -Provide proper slope of horizontal plumbing vents in attic space -Missing (2) 2x4 at owner’s entry- two locations -Missing (2) 2x10 basement -Missing (2) lvl in basement mechanical room
Erosion Control Inspection Residential Failed 01/19/2021
Misc
Corrective Action Required
10/29/2020
- EROSION CONTROL REQUIRED AT FRONT OF LOT, MAINTAIN SILT FENCE - CLEAN MUD AND GRAVEL IN STREET AT FRONT OF LOT -PROVIDE AND MAINTAIN GRAVEL FILTER -NO FURTHER INSPECTIONS UNTIL COMPLETE
Water Service Inspection - R Passed 1/20/2021 (10:30) 1/20/2021 01/20/2021
Gas Piping Inspection - Residential Passed 1/27/2021 1/27/2021 01/27/2021
Misc
Resolved
01/27/2021
Gas Service Inspection - Residential Passed 1/27/2021 1/27/2021 01/27/2021
All Rough Inspection - Residential Failed 1/27/2021 1/27/2021 01/27/2021
Misc
Corrective Action Required
01/19/2021
-Address field cut engineered truss in garage -submit engineer report on fix -Properly fasten double joist hanger(s), second floor framing above living room -Anchor bolt required within 12 inches a bottom plate splice, basement right of egress window **OK TO INSULATE**
All Rough Inspection - Residential Passed 1/29/2021 1/29/2021 01/29/2021
Misc
Resolved
01/29/2021
Driveway Inspection Partial 3/3/2021 3/3/2021 03/03/2021
Misc
Informational
03/03/2021
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Partial 3/3/2021 3/3/2021 03/03/2021
Misc
Informational
03/03/2021
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 3/10/2021 3/10/2021 03/22/2021
Misc
Informational
03/03/2021
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Passed 3/10/2021 3/10/2021 03/22/2021
Misc
Informational
03/03/2021
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Occupancy Inspection - Codes Residential Failed 5/28/2021 5/28/2021 05/28/2021
Misc
Corrective Action Required
05/28/2021
-Resolve outstanding inspection fee(s) before final c of o -Final grade and sod -Guardrail at front porch -Splash blocks at all downspout and sump pump locations -Handrail height at garage stairs must be between 34"-38"
Occupancy Inspection - Codes Residential Temporary C of O 6/18/2021 6/18/2021 06/18/2021
Misc
Corrective Action Required
05/28/2021
-Final grade and sod -Guardrail at front porch -Splash blocks at all downspout and sump pump locations **OK FOR TCO - TCO EXPIRES 7/2/21**
Plot Plan Inspection Passed 06/23/2021
Erosion Control Inspection Residential Passed 06/23/2021
Misc
Resolved
06/23/2021
Occupancy Inspection - Codes Residential Full C of O 6/23/2021 6/23/2021 06/23/2021
Misc
Resolved
06/23/2021
Documents & Images
Date Uploaded File Type Document Name
08/25/2020 Application Form RR #67 - PERMIT APP
08/25/2020 67 reserve at stoney creek roof layout- signed
08/25/2020 2423042 RF SEALS 08202020
08/25/2020 RR #67 - Charleston - Tuscan - Sheets- signed
08/25/2020 LOT 67 FINAL 7-31-20
08/26/2020 Scope of Work APPROVED ROOF TRUSS PACKAGE
08/26/2020 Drawing APPROVED TRUSS LAYOUT
08/26/2020 Plans APPROVED HOUSE PLANS
08/26/2020 Plot Plan APPROVED PLOT PLAN
09/04/2020 Receipt Receipt for transaction:2020-006050
09/04/2020 Letter DS Building Permit
10/05/2020 Letter INSPECTION SUMMARY
10/29/2020 Letter INSPECTION SUMMARY
10/29/2020 Letter INSPECTION SUMMARY
11/03/2020 Letter INSPECTION SUMMARY
01/04/2021 Letter INSPECTION SUMMARY
01/19/2021 Letter INSPECTION SUMMARY
01/19/2021 Letter INSPECTION SUMMARY
01/19/2021 Letter INSPECTION SUMMARY
01/19/2021 Letter INSPECTION SUMMARY
01/19/2021 Letter INSPECTION SUMMARY
01/19/2021 Letter INSPECTION SUMMARY
01/20/2021 Letter INSPECTION SUMMARY
01/27/2021 Letter INSPECTION SUMMARY
01/27/2021 Letter INSPECTION SUMMARY
01/27/2021 Letter INSPECTION SUMMARY
01/27/2021 RR67 Truss repair
01/27/2021 Specifications APPROVED ROOF TRUSS REPAIR
01/29/2021 Letter INSPECTION SUMMARY
03/03/2021 Letter INSPECTION SUMMARY
03/03/2021 Letter INSPECTION SUMMARY
03/22/2021 Letter INSPECTION SUMMARY
03/22/2021 Letter INSPECTION SUMMARY
03/22/2021 Letter INSPECTION SUMMARY
05/28/2021 Letter INSPECTION SUMMARY
06/16/2021 Receipt Receipt for transaction:2021-004606
06/18/2021 Letter Codes Temporary Certificate of Occupancy
06/23/2021 Letter INSPECTION SUMMARY
06/23/2021 Letter INSPECTION SUMMARY
06/23/2021 Letter Field Certificate of Occupancy
06/23/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home