Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT
07/21/2020
07/21/2020
04/19/2021
Locations
Contacts
CMH PARKS INC, Address:5000 CLAYTON RD  
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
RYAN@SUMMITHOMESKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 07/23/2020 07/21/2020
Kim Brennan
Residential Plan Review Approved 07/23/2020 07/21/2020
Kim Brennan
Planning Review (RES) Approved 07/23/2020 07/21/2020
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,183.45 $1,183.45 Paid 07/21/2020
Right of Way Permit Fee $80.00 $80.00 Paid 07/21/2020
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 07/21/2020
8331507-Sewer Connection Fee $540.00 $540.00 Paid 07/21/2020
Water Tap Fee $3,581.00 $3,581.00 Paid 07/21/2020
Water Meter Fee $455.54 $455.54 Paid 07/21/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 8/24/2020 8/24/2020 08/24/2020
Erosion Control Inspection Residential Failed 09/18/2020
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
09/18/2020
-EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -CORRECT EROSION CONTROL ON BACK OF LOT, MAINTAIN GRAVEL FITLER, REMOVE TRASH, CLEAN STREETS
Underslab Plumbing Inspection - Residential Passed 9/18/2020 9/18/2020 09/18/2020
Electrical Service Inspection Passed 11/20/2020 11/20/2020 11/20/2020
Gas Piping Inspection - Residential Passed 11/20/2020 11/20/2020 11/20/2020
Gas Service Inspection - Residential Failed 11/20/2020 11/20/2020 11/20/2020
Misc
Corrective Action Required
11/20/2020
-GAS PRESSURE AT 0 PSI, MUST MAINTAIN 10 PSI FOR 15 MINUTES
All Rough Inspection - Residential Failed 11/20/2020 11/20/2020 11/20/2020
Misc
Corrective Action Required
11/20/2020
-Fireblock furred outs in garage -Seal all top and bottom plate penetrations -Joist hanger at N garage connection to dbl header, over 4’ -Structural straps at top plate bores 50% or more at all exterior walls and all interior load bearing walls -2x10 floor joist over bored for DWV above kitchen -12” oc nailing at all abutting and intersecting wall corners (braced wall panels) -EC#2 at front entry per plans -Connect top plates at top of stairs, 2x6 to 2x4 wall -BOCCA protection plate at DWV bottom plate, 2nd floor bath -Truss bracing per plans -Anchor all columns to floor
Gas Service Inspection - Residential Passed 11/25/2020 11/25/2020 11/25/2020
Misc
Resolved
11/25/2020
All Rough Inspection - Residential Passed 11/25/2020 11/25/2020 11/25/2020
Misc
Resolved
11/25/2020
Sewer Service Inspection - R Passed 12/7/2020 (9:30) 12/7/2020 12/07/2020
Water Service Inspection - R Passed 12/8/2020 (10:45) 12/8/2020 12/08/2020
Driveway Inspection Passed 12/17/2020 (P.M.) 12/17/2020 12/18/2020
Misc
Informational
12/18/2020
On Thursday, 12-17-2020. A driveway inspection was held and passed standards to pour concrete.
Sidewalk Inspection Passed 12/17/2020 (P.M.) 12/17/2020 12/18/2020
Misc
Informational
12/18/2020
On Thursday, 12-17-2020. A sidewalk inspection was conducted and passed city standard.
Occupancy Inspection - Codes Residential Failed 2/10/2021 2/10/2021 02/10/2021
Misc
Corrective Action Required
02/10/2021
-Complete final grade and sod -Splash blocks at all downspout and sump pump discharge locations, minimum 36” from foundation -Seal all penetrations in siding, seal along top of AC disconnect and meter can -guardrail required at front porch, more than 30” from grade -Obtain lawn irrigation system permit
Occupancy Inspection - Codes Residential Temporary C of O 3/12/2021 3/12/2021 03/12/2021
Misc
Corrective Action Required
02/10/2021
-SUMP PUMP DISCHARGE MINIMUM 36" FROM FOUNDATION -SECURE AND SUPPORT AC ELECTRICAL WHIP, WHIP CURRENTLY LAYING ON GRADE -REPAIR DAMAGED SIDEWALK AT FRONT OF LOT OK FOR TCO - TCO EXPIRES 3/26/21
Plot Plan Inspection Passed 3/12/2021 3/12/2021 03/12/2021
Occupancy Inspection - Codes Residential Failed 4/2/2021 4/2/2021 04/02/2021
Misc
Corrective Action Required
03/12/2021
cut down the water valve on the NE side of the lot flush with grade. reschedule when complete.
Occupancy Inspection - Codes Residential Full C of O 4/20/2021 4/20/2021 04/19/2021
Misc
Resolved
04/19/2021
Documents & Images
Date Uploaded File Type Document Name
07/21/2020 Letter Permit Application and license tax form
07/21/2020 Plot Plan Approved Plot Plan
07/21/2020 Drawing Approved Truss Layout
07/21/2020 Drawing Approved Truss Package
07/21/2020 Drawing Approved Drawings
07/21/2020 Receipt Receipt for transaction:2020-004606
07/21/2020 Letter DS Building Permit
08/24/2020 Lot 59 Hawthorne Ridge footing
08/24/2020 Letter INSPECTION SUMMARY
08/26/2020 Lot 59 Hawthorne Ridge wall inspection
09/18/2020 Letter INSPECTION SUMMARY
09/18/2020 Letter INSPECTION SUMMARY
09/18/2020 Letter INSPECTION SUMMARY
11/20/2020 Letter INSPECTION SUMMARY
11/20/2020 Letter INSPECTION SUMMARY
11/20/2020 Letter INSPECTION SUMMARY
11/20/2020 Letter INSPECTION SUMMARY
11/23/2020 59 Hawthorne Ridge Floor Joist Hole Letter
11/25/2020 Letter INSPECTION SUMMARY
11/25/2020 Letter INSPECTION SUMMARY
12/07/2020 Letter INSPECTION SUMMARY
12/08/2020 Letter INSPECTION SUMMARY
02/10/2021 Letter INSPECTION SUMMARY
03/12/2021 Letter Codes Temporary Certificate of Occupancy
03/12/2021 Letter INSPECTION SUMMARY
04/02/2021 Letter INSPECTION SUMMARY
04/19/2021 Letter Field Certificate of Occupancy
04/19/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home