Permit Application Status

PRRES20201232


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20201232
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT
05/14/2020
05/15/2020
03/10/2021
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
DUSTIN@SUMMITHOMESKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 05/18/2020 05/14/2020
Kim Brennan
Residential Plan Review Approved 05/18/2020 05/14/2020
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,494.00 $1,494.00 Paid 05/14/2020
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 05/14/2020
7232302-Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 05/14/2020
8331504-EFHB Middle Big Creek, Full $669.60 $669.60 Paid 05/14/2020
8331507-Sewer Connection Fee $600.00 $600.00 Paid 05/14/2020
8331401-Water Tap Fee $3,477.00 $3,477.00 Paid 05/14/2020
8350015-Water Meter Fee $425.02 $425.02 Paid 05/14/2020
9110080-Not Ready Inspection Fee $50.00 $50.00 Paid 01/11/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 6/12/2020 (1:30) 6/12/2020 06/12/2020
Underslab Plumbing Inspection - Residential Failed 7/9/2020 7/9/2020 07/09/2020
Misc
Corrective Action Required
07/09/2020
- Standing water along sections of DWV preventing complete inspection. Either pump out water or wait until conditions improve to reschedule inspection. - Maintain erosion control on lot, clean mud and gravel in street at front of lot before rescheduling inspection.
Erosion Control Inspection Residential Failed 07/09/2020
Misc
Corrective Action Required
07/09/2020
- Mainain erosion control on lot. Clean mud and gravel in street before scheduling any future inspections.
Underslab Plumbing Inspection - Residential Passed 7/14/2020 7/14/2020 07/14/2020
Misc
Resolved
07/14/2020
Electrical Service Inspection Passed 9/18/2020 9/18/2020 09/18/2020
Gas Piping Inspection - Residential Failed 9/18/2020 9/18/2020 09/18/2020
Misc
Corrective Action Required
09/18/2020
- Gas piping incomplete - Gas pressure at 7 psi, must maintain 10 psi for 15 minutes
Gas Service Inspection - Residential Failed 9/18/2020 9/18/2020 09/18/2020
Misc
Corrective Action Required
09/18/2020
- Gas piping incomplete - Gas pressure at 7 psi, must maintain 10 psi for 15 minutes
All Rough Inspection - Residential Failed 9/18/2020 9/18/2020 09/18/2020
Misc
Corrective Action Required
09/18/2020
- H2.5 strap missing - garage - Garage PFH per plans - structural straps required at all top plates bored 50% or more at all exterior walls and interior load bearing walls - Protection plate at DWV kitchen window bottom - Joist hanger required at joist connection to beam living room side at stairwell - Protection plate at refrigerator pex bottom plate - Security blocking at front, back door - Joist hangers required at all floor joist (4’ or more) connected to dbl lvl above back door in kitchen - Support DWV ever 48” o.c. - Incomplete DWV at chase in living room - (2) 3” SCH 40 steel columns missing at W13x19 steel beam as shown in plans, beam supported at E end by steel column - EC#2 per plans - Connect 2x6 to 2x4 top plates at 2nd floor stairs - Protection plate at top and bottom plate DWV master bath - Protection plate at bottom radon master closet - H2.5 straps missing back porch - Nail off all truss hangers - Truss hangers per plans - Joist hangers required at header above HVAC basement - Anchor all columns to floor - Header with joist hangers required at connections for cut dbl floor joists for HVAC - W side basement - Gas line incomplete - Joist hangers required at cantilever header and joists in basement - Joist hangers required at basement to floor landing floor joists and dbl joist header
Gas Piping Inspection - Residential Failed 9/30/2020 9/30/2020 09/30/2020
Misc
Corrective Action Required
09/18/2020
- Gas piping incomplete - Gas pressure at 0 psi, must maintain 10 psi for 15 minutes
Gas Service Inspection - Residential Failed 9/30/2020 9/30/2020 09/30/2020
Misc
Corrective Action Required
09/18/2020
- Gas piping incomplete - Gas pressure at 0 psi, must maintain 10 psi for 15 minutes
All Rough Inspection - Residential Failed 9/30/2020 9/30/2020 09/30/2020
Misc
Corrective Action Required
09/30/2020
-H2.5 strap missing - garage - structural straps required at all top plates bored 50% or more at all exterior walls and interior load bearing walls - Incomplete DWV at chase in living room - EC#2 per plans - Header with joist hangers required at connections for cut dbl floor joists for HVAC - W side basement - dbl joist hanger tail joist connection to header, nail off header joist hanger - Gas line incomplete
All Rough Inspection - Residential Not Ready 10/6/2020 10/6/2020 10/06/2020
Misc
Corrective Action Required
09/30/2020
-H2.5 strap missing - garage - structural straps required at all top plates bored 50% or more at all exterior walls and interior load bearing walls - EC#2 per plans -Gas line incomplete -HOUSE INSULATED WITHOUT APPROVAL -NOT READY FOR REINSPECTION, TRADES WORKING ON CORRECTIONS AT TIME OF INSPECTION. -
Sewer Service Inspection - R Passed 10/7/2020 (9:30) 10/7/2020 10/07/2020
All Rough Inspection - Residential Failed 10/8/2020 10/8/2020 10/08/2020
Misc
Corrective Action Required
10/06/2020
- EC#2 per plans -1st and 2nd floor -HOUSE INSULATED WITHOUT APPROVAL - DO NOT ROCK WITHOUT APPROVAL
Gas Piping Inspection - Residential Passed 10/8/2020 10/8/2020 10/08/2020
Misc
Resolved
10/08/2020
Gas Service Inspection - Residential Passed 10/8/2020 10/8/2020 10/08/2020
Misc
Resolved
10/08/2020
Water Service Inspection - R Passed 10/8/2020 (11:30) 10/8/2020 10/08/2020
All Rough Inspection - Residential Passed 10/13/2020 10/13/2020 10/13/2020
Misc
Resolved
10/13/2020
Driveway Inspection Partial 10/14/2020 (P.M.) 10/14/2020 10/14/2020
Misc
Informational
10/14/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 10/21/2020 10/21/2020 10/21/2020
Misc
Informational
10/14/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Partial 12/1/2020 (P.M.) 12/1/2020 12/01/2020
Misc
Informational
12/01/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Sidewalk Inspection Passed 12/8/2020 12/8/2020 12/09/2020
Misc
Informational
12/01/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Occupancy Inspection - Codes Residential Temporary C of O 1/7/2021 1/7/2021 01/07/2021
Misc
Corrective Action Required
01/07/2021
-Resolve outstanding inspection fee(s) before final c of o -Complete final grade and sod -Splash blocks at all downspout and sump pump discharge locations, minimum 36” from foundation OK FOR TCO
Occupancy Inspection - Codes Residential Temporary C of O 2/11/2021 2/11/2021 02/11/2021
Misc
Corrective Action Required
01/07/2021
-Resolve outstanding inspection fee(s) before final c of o -Complete final grade and sod -Splash blocks at all downspout and sump pump discharge locations, minimum 36” from foundation OK FOR TCO - TCO EXTENSION - EXPIRES 4/2/21
Plot Plan Inspection Passed 3/10/2021 3/10/2021 03/10/2021
Occupancy Inspection - Codes Residential Full C of O 3/10/2021 3/10/2021 03/10/2021
Misc
Resolved
03/10/2021
Documents & Images
Date Uploaded File Type Document Name
05/14/2020 Letter Permit Application
05/14/2020 Plot Plan Approved Plot Plan
05/14/2020 Plans Approved Drawings
05/14/2020 Plans Approved Truss Package
05/14/2020 Plans Approved Truss Layout
05/14/2020 Receipt Receipt for transaction: 2020-002147
05/15/2020 Letter DS Building Permit
06/12/2020 Letter INSPECTION SUMMARY
07/09/2020 Letter INSPECTION SUMMARY
07/09/2020 Letter INSPECTION SUMMARY
07/14/2020 Letter INSPECTION SUMMARY
09/18/2020 Letter INSPECTION SUMMARY
09/18/2020 Letter INSPECTION SUMMARY
09/18/2020 Letter INSPECTION SUMMARY
09/18/2020 Letter INSPECTION SUMMARY
09/30/2020 Letter INSPECTION SUMMARY
09/30/2020 Letter INSPECTION SUMMARY
09/30/2020 Letter INSPECTION SUMMARY
10/06/2020 Letter INSPECTION SUMMARY
10/07/2020 Letter INSPECTION SUMMARY
10/08/2020 Letter INSPECTION SUMMARY
10/08/2020 Letter INSPECTION SUMMARY
10/08/2020 Letter INSPECTION SUMMARY
10/08/2020 Letter INSPECTION SUMMARY
10/13/2020 Letter INSPECTION SUMMARY
10/14/2020 Letter INSPECTION SUMMARY
10/21/2020 Letter INSPECTION SUMMARY
12/01/2020 Letter INSPECTION SUMMARY
12/09/2020 Letter INSPECTION SUMMARY
01/07/2021 Letter INSPECTION SUMMARY
01/07/2021 Letter Codes Temporary Certificate of Occupancy
01/11/2021 Receipt Receipt for transaction:2021-000136
02/11/2021 Email RE External RR83-1512 SW Georgetown Dr
02/11/2021 Letter Codes Temporary Certificate of Occupancy
03/10/2021 Letter INSPECTION SUMMARY
03/10/2021 Letter Field Certificate of Occupancy
03/10/2021 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home