Permit Application Status

PRRES20200613


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20200613
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED PATIO
03/09/2020
03/11/2020
11/23/2020
Locations
Contacts
CMH PARKS INC, Address:5000 CLAYTON RD  
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
RYAN@SUMMITHOMESKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Planning Review (RES) Approved 03/11/2020 03/10/2020
Kim Brennan
Plot Plan Review Approved 03/11/2020 03/10/2020
Kim Brennan
As-graded plot plan
Corrective Action Required
03/09/2020

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Residential Plan Review Approved 03/11/2020 03/09/2020
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,135.94 $1,135.94 Paid 03/11/2020
Right of Way Permit Fee $80.00 $80.00 Paid 03/11/2020
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 03/11/2020
8331507-Sewer Connection Fee $480.00 $480.00 Paid 03/11/2020
Water Tap Fee $3,477.00 $3,477.00 Paid 03/11/2020
Water Meter Fee $425.02 $425.02 Paid 03/11/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 3/27/2020 (1:30) 3/27/2020 03/27/2020
Underslab Plumbing Inspection - Residential Failed 4/17/2020 4/17/2020 04/17/2020
Misc
Corrective Action Required
04/17/2020
- Unable to inspect complete DWV system due to standing water and mud covering. Please reschedule inspection when site conditions allow for a complete inspection. -
Underslab Plumbing Inspection - Residential Passed 4/20/2020 4/20/2020 04/20/2020
Misc
Resolved
04/20/2020
Piers/Caissons Inspection - Residential Passed 5/20/2020 (1:15) 5/20/2020 05/20/2020
Misc
Informational
05/20/2020
1 24 x 36 w/ 4 #4 vert bars
Sewer Service Inspection - R Passed 6/17/2020 (1:00) 6/17/2020 06/17/2020
Water Service Inspection - R Passed 6/26/2020 (10:00) 6/26/2020 06/26/2020
Electrical Service Inspection Failed 7/10/2020 7/10/2020 07/10/2020
Misc
Corrective Action Required
07/10/2020
- UFER ground required - Color code ufer ground - Remove green panel bonding screw from sub panel
Gas Piping Inspection - Residential Passed 7/10/2020 7/10/2020 07/10/2020
Gas Service Inspection - Residential Failed 7/10/2020 7/10/2020 07/10/2020
Misc
Corrective Action Required
07/10/2020
- UFER ground required
All Rough Inspection - Residential Failed 7/10/2020 7/10/2020 07/10/2020
Misc
Corrective Action Required
07/10/2020
- tighten all anchor bolts in garage - Fireblock chase and fir down in garage - Seal all penetrations in top plate - garage, 2nd floor bed #3 - Support DWV every 48” o.c. - Strap top plate for DWV owner entry - Security blocking back door - Protect and secure pex at showers per manufacturer listing - Truss hangers per plans - EC#2 Per plans - H2.5 straps missing 2nd floor - Fireblock 2nd floor chase - Connect top plates at top stair landing at 2x6 to 2x4 wall - H2.5 straps at trusses above covered rear patio - Install washers and nuts at all anchor bolts in basement
Electrical Service Inspection Passed 7/15/2020 7/15/2020 07/15/2020
Misc
Resolved
07/15/2020
All Rough Inspection - Residential Failed 7/15/2020 7/15/2020 07/15/2020
Misc
Corrective Action Required
07/10/2020
- Truss hangers per plans - (2) LUS24 missing above laundry 1st floor - Install washers and nuts at all anchor bolts in basement OK to Insulate
All Rough Inspection - Residential Passed 7/16/2020 7/16/2020 07/16/2020
Misc
Resolved
07/16/2020
Driveway Inspection Passed 8/3/2020 8/3/2020 08/04/2020
Misc
Informational
08/04/2020
On Monday, 8-03-2020. A drive approach inspection was performed and was passed for the concrete installation.
Gas Service Inspection - Residential Passed 9/8/2020 9/8/2020 09/08/2020
Misc
Resolved
09/08/2020
Occupancy Inspection - Codes Residential Temporary C of O 9/18/2020 9/18/2020 09/18/2020
Miscellaneous Correction
Corrective Action Required
09/18/2020
-EROSION CONTROL REQUIRED BEFORE FURTHER INSPECTION -PROVIDE SOD -PROVIDE SPLASH BLOCKS -PROVIDE PROPER DRAINAGE AWAY FROM FOUNDATION -EXTERIOR LIGHT FIXTURES TO BE SEALED FIXTURES
Plot Plan Inspection Failed 11/10/2020
Misc
Corrective Action Required
11/10/2020
-UNCOVER MANHOLE MH2-6 AT FRONT OF LOT N SIDE AS SHOWN ON PLOT PLAN -COMPLETE SOD AT BACK OF HOUSE
Occupancy Inspection - Codes Residential Failed 11/10/2020 11/10/2020 11/10/2020
Miscellaneous Correction
Corrective Action Required
09/18/2020
-UNCOVER MANHOLE MH2-6 AT FRONT OF LOT N SIDE AS SHOWN ON PLOT PLAN -COMPLETE SOD AT BACK OF HOUSE
Plot Plan Inspection Passed 11/23/2020
Misc
Resolved
11/23/2020
Occupancy Inspection - Codes Residential Full C of O 11/23/2020 11/23/2020 11/23/2020
Miscellaneous Correction
Resolved
11/23/2020
Documents & Images
Date Uploaded File Type Document Name
03/09/2020 Letter Codes Residential Plan Review
03/11/2020 Receipt Receipt for transaction: 2020-001108
03/11/2020 Letter DS Building Permit
03/12/2020 Plot Plan DOC031220-015
03/27/2020 Letter INSPECTION SUMMARY
04/17/2020 Letter INSPECTION SUMMARY
04/20/2020 Letter INSPECTION SUMMARY
05/20/2020 Letter INSPECTION SUMMARY
06/17/2020 Letter INSPECTION SUMMARY
06/26/2020 Letter INSPECTION SUMMARY
07/10/2020 Letter INSPECTION SUMMARY
07/10/2020 Letter INSPECTION SUMMARY
07/10/2020 Letter INSPECTION SUMMARY
07/10/2020 Letter INSPECTION SUMMARY
07/15/2020 Letter INSPECTION SUMMARY
07/15/2020 Letter INSPECTION SUMMARY
07/16/2020 Letter INSPECTION SUMMARY
09/08/2020 Letter INSPECTION SUMMARY
09/18/2020 Letter INSPECTION SUMMARY
09/18/2020 Letter Codes Temporary Certificate of Occupancy
11/05/2020 Plot Plan approved as-built
11/10/2020 Letter INSPECTION SUMMARY
11/10/2020 Letter INSPECTION SUMMARY
11/23/2020 Letter INSPECTION SUMMARY
11/23/2020 Letter Field Certificate of Occupancy
11/23/2020 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home