Permit Application Status

PRRES20200528


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20200528
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - COVERED PATIO - UNFININSHED BASEMENT - LAWN IRRIGATION
02/28/2020
03/30/2020
11/13/2020
Locations
Contacts
BELLAH HOMES LLC, Address:P O BOX 346, Phone:(816) 697-2870  
TROY@BELLAHHOMES.COM  
A & D HEATING AND COOLING INC, Address:2006 W MAIN ST, Phone:(816) 537-7952  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
Reviews
Review Type Outcome Est. Completion Date Completed
Planning Review (RES) Approved 03/03/2020 03/27/2020
Victoria Nelson
Plot Plan Review Approved 03/03/2020 03/27/2020
Dylan Eppert
Easements
Corrective Action Required
03/26/2020

All easements with dimensions must be provided on the plot plan. LABEL U/E IN ALLEY WITH DIMENSIONS.
City infrustructure
Corrective Action Required
03/26/2020

Show all manholes, water valve boxes, fire hydrants, and stormwater structures. Field inlet in the alley must have top of elevation and throat elevation.
Basement egress
Corrective Action Required
03/26/2020

Basement egress location(s) and elevation of the lowest adjacent grade must be provided on the plot plan. Egress well not on plot plan must have lag as well.
Spot elevations
Corrective Action Required
03/26/2020

Spot elevations and/or drainage flow arrows shall be provided throughout the lot. I am not getting a 2% slope towards the SE Mary St or NE property line.
Miscellaneous Correction
Corrective Action Required
03/26/2020

Provide finished contours on the plot plan.
As-graded plot plan
Corrective Action Required
03/26/2020

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy.
Residential Plan Review Approved 03/03/2020 02/28/2020
Dylan Eppert
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $1,100.06 $1,100.06 Paid 03/30/2020
8331507-Sewer Connection Fee $450.00 $450.00 Paid 03/30/2020
Water Tap Fee $3,477.00 $3,477.00 Paid 03/30/2020
Water Meter Fee $425.02 $425.02 Paid 03/30/2020
Right of Way Permit Fee $80.00 $80.00 Paid 03/30/2020
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 03/30/2020
Additional Permit Fee $30.00 $30.00 Paid 03/30/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 4/6/2020 at 1:15 PM 04/16/2020
Misc
Informational
04/16/2020
3rd party footing signed & stamped by David P Ainsworth for Bella Homes - Notes: ufer ground rod is located in north basement sidewall about 10' E of the rear garage wall -
Underslab Plumbing Inspection - Residential Passed 4/22/2020 4/22/2020 04/22/2020
Sewer Service Inspection - R Passed 5/14/2020 (10:45) 5/14/2020 at 11:20 AM 05/14/2020
Water Service Inspection - R Passed 5/15/2020 (9:00) 5/15/2020 at 9:35 AM 05/15/2020
Erosion Control Inspection Residential Failed 7/28/2020 07/28/2020
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
07/28/2020
- MAINTAIN SILT FENCE - - MAINTAIN GRAVEL FILTER -
Electrical Service Inspection Passed 7/28/2020 7/28/2020 07/28/2020
Gas Piping Inspection - Residential Passed 7/28/2020 7/28/2020 07/28/2020
Gas Service Inspection - Residential Passed 7/28/2020 7/28/2020 07/28/2020
All Rough Inspection - Residential Failed 7/28/2020 7/28/2020 07/28/2020
Misc
Corrective Action Required
07/28/2020
- TIGHTEN ANCHOR BOLTS THROUGHOUT - - SUPPORT 2" DWV AT MIDPOINT - - PROVIDE PROTECTION PLATE ELETRICAL NEAR FRONT DOOR - - SEAL GAS LINE PENETRATION AT FLOOR FIRE PLACE - - SEAL ELECTRICAL PENETRATIONS BOTTOM PLATE DINING AREA - - PROVIDE PROTECTION SERVICE ENTRY CABLE GARAGE SILL PLATE - - PROVIDE 3 STUDS UNDER LVL DINING GREAT ROOM - - PROVIDE 3 STUDS UNDER LVL GREAT ROOM BED # 2 - - SOLID BLOCK ABOVE BEAMS IN BASEMENT - - BOX IN CANTILEVER AT FIRE PLACE - - WHERE JOIST RUN PARALLEL TO FOUNDATION BLOCKING SHALL BE PROVIDED IN TWO SPACES MOST ADJACENT TO FOUNDATION WALL 4'-0'' O.C.- - ENGINEER ADDRESS RAFTERS LANDING ON BLOCKS THROUGHOUT -
All Rough Inspection - Residential Passed 7/31/2020 7/31/2020 07/31/2020
Misc
Resolved
07/31/2020
Sidewalk Inspection Partial 9/14/2020 (P.M.) 9/14/2020 09/14/2020
Misc
Informational
09/14/2020
Forms were placed and aggregate was present and compacted.
Misc
Informational
09/14/2020
Forms were placed and aggregate was present and compacted. Terry asked about extending the house approach to the curb? I asked Bob Burns since it wasn’t on the plot plan. The answer was NO on pouring something in the right of way space other than the sidewalk. RP 9-14-20
Sidewalk Inspection Failed 9/18/2020 9/18/2020 09/18/2020
Misc
Informational
09/14/2020
Forms were placed and aggregate was present and compacted.
Misc
Informational
09/14/2020
Forms were placed and aggregate was present and compacted. Terry asked about extending the house approach to the curb? I asked Bob Burns since it wasn’t on the plot plan. The answer was NO on pouring something in the right of way space other than the sidewalk. RP 9-14-20
Misc
Corrective Action Required
09/18/2020
Still missing 20 feet of sidewalk. Need to call in another inspection when ready to pour missing sections. RP 9-18-20.
Erosion Control Inspection Residential Failed 11/06/2020
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
07/28/2020
Immediate street clean up required. Remove debris from sidewalk & curb/gutter
Occupancy Inspection - Codes Residential Failed 11/6/2020 11/6/2020 11/06/2020
Misc
Corrective Action Required
11/06/2020
-As built plot plan required. Inspection required prior to sod -Sidewalk inspection failed 9-18-2020 contact Development Services to resolve this issue -Final grade per approved as built plot plan and sod -Provide gutters and downspouts. Downspouts to discharge minimum 36 inches from foundation -Seal top and sides of AC disconnect, electric meter enclosure, exterior lighting exposed to the elements junction boxes and all exterior penetrations -remove trash and construction debris from site -Paint exterior gas piping with corrosion resistant product -Provide all fasteners for panel cover in garage -Fireblock through for penetrations under master tub, conductor penetrations -Complete lighting fixture installation master bath
Sidewalk Inspection Passed 11/10/2020 (P.M.) 11/10/2020 11/10/2020
Misc
Informational
09/18/2020
Forms were placed and aggregate was present and compacted.
Misc
Informational
09/18/2020
Forms were placed and aggregate was present and compacted. Terry asked about extending the house approach to the curb? I asked Bob Burns since it wasn’t on the plot plan. The answer was NO on pouring something in the right of way space other than the sidewalk. RP 9-14-20
Misc
Corrective Action Required
09/18/2020
Still missing 20 feet of sidewalk. Need to call in another inspection when ready to pour missing sections. RP 9-18-20.
Misc
Informational
11/10/2020
Finished sidewalk never was called in for pre-inspection. Sidewalk does met LS and ADA specs. RP 11-10-20
Occupancy Inspection - Codes Residential Full C of O 11/13/2020 11/13/2020 11/13/2020
Misc
Resolved
11/13/2020
-As built plot plan required. Inspection required prior to sod -Sidewalk inspection failed 9-18-2020 contact Development Services to resolve this issue -Final grade per approved as built plot plan and sod -Provide gutters and downspouts. Downspouts to discharge minimum 36 inches from foundation -Seal top and sides of AC disconnect, electric meter enclosure, exterior lighting exposed to the elements junction boxes and all exterior penetrations -remove trash and construction debris from site -Paint exterior gas piping with corrosion resistant product -Provide all fasteners for panel cover in garage -Fireblock through for penetrations under master tub, conductor penetrations -Complete lighting fixture installation master bath
Plot Plan Inspection Passed 11/16/2020 11/13/2020
Erosion Control Inspection Residential Passed 11/13/2020
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
11/13/2020
Immediate street clean up required. Remove debris from sidewalk & curb/gutter
Lawn Sprinkler Final Passed 11/13/2020
Documents & Images
Date Uploaded File Type Document Name
03/27/2020 Letter Codes Residential Plan Review
03/27/2020 Plot Plan 3205 SW Mary St. Plot Plan Approved
03/27/2020 Plans Pergola Park Lot 107 Buildin Plan (Approved)
03/30/2020 Receipt Receipt for transaction:2020-001316
03/30/2020 Letter DS Building Permit
04/08/2020 Engineer Report/Study M L Crose 3205 SW Mary St LSMO Bellah Permit 2020-0528 3rd Party Footing Inspection Report 4-6-20
04/16/2020 Letter INSPECTION SUMMARY
04/22/2020 Letter INSPECTION SUMMARY
05/14/2020 Letter INSPECTION SUMMARY
05/15/2020 Letter INSPECTION SUMMARY
07/28/2020 Letter INSPECTION SUMMARY
07/28/2020 Letter INSPECTION SUMMARY
07/28/2020 Letter INSPECTION SUMMARY
07/28/2020 Letter INSPECTION SUMMARY
07/30/2020 Letter Framing Report
07/31/2020 Letter INSPECTION SUMMARY
09/14/2020 Letter INSPECTION SUMMARY
09/18/2020 Letter INSPECTION SUMMARY
11/06/2020 Letter INSPECTION SUMMARY
11/06/2020 Letter INSPECTION SUMMARY
11/06/2020 Letter INSPECTION SUMMARY
11/10/2020 Letter INSPECTION SUMMARY
11/13/2020 Plans APPROVED AS-BUILT
11/13/2020 Letter Field Certificate of Occupancy
11/13/2020 Letter Codes Final Certificate of Occupancy
11/13/2020 Letter INSPECTION SUMMARY
11/13/2020 Letter INSPECTION SUMMARY
11/13/2020 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home