Permit Application Status

PRRES20193524


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20193524
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW SINGLE FAMILY UNFINISHED BASEMENT
12/03/2019
12/05/2019
11/24/2020
Locations
Contacts
CMH PARKS INC, Address:5000 CLAYTON RD  
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
PERMITTING@SUMMITHOMESKC.COM  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 12/05/2019 12/03/2019
Steve Conrick
Residential Plan Review Approved 12/05/2019 12/03/2019
Steve Conrick
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $943.65 $943.65 Paid 12/05/2019
Right of Way Permit Fee $80.00 $80.00 Paid 12/05/2019
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 12/05/2019
8331507-Sewer Connection Fee $360.00 $360.00 Paid 12/05/2019
Water Tap Fee $3,477.00 $3,477.00 Paid 12/05/2019
Water Meter Fee $425.02 $425.02 Paid 12/05/2019
Not Ready Inspection Fee $50.00 $50.00 Paid 10/30/2020
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 1/14/2020 01/14/2020
Underslab Plumbing Inspection - Residential Passed 2/28/2020 2/28/2020 02/28/2020
Sewer Service Inspection - R Passed 3/4/2020 3/4/2020 03/04/2020
Water Service Inspection - R Passed 3/5/2020 (10:30) 3/5/2020 03/05/2020
Piers/Caissons Inspection - Residential Passed 4/13/2020 (1:15) 4/13/2020 04/13/2020
Misc
Informational
04/13/2020
(2) 24 x 36 covered patio piers
All Rough Inspection - Residential Not Ready 5/12/2020 5/12/2020 05/12/2020
Misc
Corrective Action Required
05/12/2020
INSPECTION NOT PERFORMED - NO CITY APPROVED TRUSS PLANS OR FULL SET OF CITY APPROVED PLANS ON SITE - - MAINTAIN GRAVEL FILTER ON LOT AND CLEAN GRAVEL AND MUD ON STREET PRIOR TO REINSPECTION -
Erosion Control Inspection Residential Failed 5/12/2020 05/12/2020
DCM5 ESC INSP DENIED
Corrective Action Required
05/12/2020
- MAINTAIN GRAVEL FILTER ON LOT AND CLEAN GRAVEL AND MUD ON STREET PRIOR TO REINSPECTION -
Electrical Service Inspection Passed 5/14/2020 05/14/2020
Gas Piping Inspection - Residential Passed 5/14/2020 05/14/2020
Gas Service Inspection - Residential Passed 5/14/2020 05/14/2020
All Rough Inspection - Residential Failed 5/14/2020 5/14/2020 05/14/2020
Misc
Corrective Action Required
05/12/2020
- Maintain gravel filter at drive - Seal all upward penetrations at top plate - PFH per plans in garage - Strap top plates N garage wall and above fireplace - Seal penetrations in flue chase 1st floor - Protect and secure PEX at showers - Fire stopping at tub traps, showers - Protect electrical panel from PEX water line above
All Rough Inspection - Residential Failed 5/18/2020 5/18/2020 05/18/2020
Misc
Corrective Action Required
05/14/2020
- Seal all upward penetrations at top plate-master bath WC - PFH per plans in garage - Strap top plates above fireplace - Seal penetrations in flue chase 1st floor - Protect and secure PEX at showers - Fire stopping at tub traps, showers - Protect electrical panel from PEX water line above
All Rough Inspection - Residential Failed 5/19/2020 5/19/2020 05/19/2020
Misc
Corrective Action Required
05/18/2020
- Seal all upward penetrations at top plate-master bath WC
All Rough Inspection - Residential Passed 5/20/2020 5/20/2020 05/20/2020
Misc
Resolved
05/20/2020
- Seal all upward penetrations at top plate-master bath WC
Driveway Inspection Passed 6/15/2020 6/15/2020 06/16/2020
Misc
Informational
06/16/2020
On Monday, 6-15-2020. I performed a driveway inspection at the aforementioned location and found all forming and sub grade to be acceptable for drive installation. Drive Passes inspection
Occupancy Inspection - Codes Residential Failed 10/14/2020 10/14/2020 10/14/2020
Misc
Corrective Action Required
10/14/2020
-Final sidewalk inspection -Resolve outstanding inspection fee(s) before final C of O -Guardrail required at front porch, more than 30” from grade -Complete final grade and sod -Seal all penetrations in siding, seal along top of meter can and AC disconnect -GFCI receptacle at back porch testing as open ground -Seal around all exterior light fixtures -Splash blocks at all downspout and sump pump discharge locations, minimum 36” from foundation -Address broken water meter lid, tolerance from top of meter to lid must be between 14”-18” -Remove all paint covers from smokes -Install handle/lock at sliding patio door, two locking devices required at sliding door -complete tile at kitchen counter receptacle E side -Install garage disposal at kitchen sink -Non combustible attic access cover in garage -Repair drywall at laundry receptacle
Sidewalk Inspection Passed 6/15/2020 6/15/2020 11/13/2020
Misc
Informational
06/16/2020
Sidewalk passed inspection on 6-15-2020. Sub grade and forming met all standards needed for walk to be installed.
Misc
Corrective Action Required
06/16/2020
On final visual of finish of concrete it was determined the sidewalk on the Arborwood side of street does not pass inspection due defacing of the concrete. Someone with a dog walked through the concrete leaving it unacceptable.
Misc
Resolved
11/13/2020
On 11-12-2020. The contractor removed and replaced 80 LF of sidewalk due to the walk having foot prints in them. The contractor replaced the walk and passed inspection.
Occupancy Inspection - Codes Residential Full C of O 11/24/2020 11/24/2020 11/24/2020
Misc
Resolved
11/24/2020
Plot Plan Inspection Passed 11/24/2020
Documents & Images
Date Uploaded File Type Document Name
12/05/2019 Receipt Receipt for transaction: 2019-007595
12/05/2019 Letter DS Building Permit
12/05/2019 Plot Plan DOC120519-017
01/14/2020 A127B308-69FA-4F7F-BED8-EB110E7D2BC6
01/14/2020 Letter INSPECTION SUMMARY
02/28/2020 Letter INSPECTION SUMMARY
03/04/2020 Letter INSPECTION SUMMARY
03/05/2020 Letter INSPECTION SUMMARY
04/13/2020 Letter INSPECTION SUMMARY
05/12/2020 Letter INSPECTION SUMMARY
05/12/2020 Letter INSPECTION SUMMARY
05/14/2020 Letter INSPECTION SUMMARY
05/14/2020 Letter INSPECTION SUMMARY
05/14/2020 Letter INSPECTION SUMMARY
05/14/2020 Letter INSPECTION SUMMARY
05/18/2020 Letter INSPECTION SUMMARY
05/19/2020 Letter INSPECTION SUMMARY
05/20/2020 Letter INSPECTION SUMMARY
10/14/2020 Letter INSPECTION SUMMARY
10/30/2020 Receipt Receipt for transaction: 2020-007289
11/24/2020 Letter Field Certificate of Occupancy
11/24/2020 Letter Codes Final Certificate of Occupancy
11/24/2020 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home