Permit Application Status

PRRES20193192


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20193192
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT
10/30/2019
11/04/2019
09/25/2020
Locations
Contacts
CMH PARKS INC, Address:5000 CLAYTON RD  
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
KIMBEL MECHANICAL SYSTEMS, INC, Address:1936 N SHILOH DR, Phone:(479) 756-1099  
DUSTIN@SUMMITHOMESKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 11/01/2019 11/01/2019
Kim Brennan
Residential Plan Review Approved 11/01/2019 10/30/2019
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $964.60 $964.60 Paid 11/04/2019
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 11/04/2019
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 11/04/2019
8331504-EFHB Middle Big Creek, Full $435.24 $435.24 Paid 11/04/2019
8331507-Sewer Connection Fee $390.00 $390.00 Paid 11/04/2019
8331401-Water Tap Fee $3,477.00 $3,477.00 Paid 11/04/2019
8350015-Water Meter Fee $425.02 $425.02 Paid 08/31/2020
$455.54
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 12/13/2019 (1:00) 12/13/2019 12/13/2019
Sewer Service Inspection - R Passed 2/11/2020 (11:30) 2/11/2020 02/11/2020
Water Service Inspection - R Passed 2/11/2020 02/11/2020
Underslab Plumbing Inspection - Residential Failed 2/24/2020 2/24/2020 02/24/2020
Misc
Corrective Action Required
02/24/2020
- If running interior drain tile diagonal across it needs to reach opposite diagonal corner footing. Interior drain tile currently several feet short of opposite foundation footing curled back at pier pad.
Underslab Plumbing Inspection - Residential Passed 3/2/2020 3/2/2020 03/02/2020
Misc
Resolved
03/02/2020
Electrical Service Inspection Passed 5/14/2020 5/14/2020 05/14/2020
Gas Piping Inspection - Residential Passed 5/14/2020 5/14/2020 05/14/2020
Gas Service Inspection - Residential Passed 5/14/2020 5/14/2020 05/14/2020
All Rough Inspection - Residential Failed 5/14/2020 5/14/2020 at 12:40 PM 05/14/2020
Misc
Corrective Action Required
05/14/2020
- PROVIDE HANGERS PER TRUSS SCHEDULE - - SEAL AND SECURE GAS LINE FIREPLACE - - PROVIDE STUD SHOES MASTER VANITY - - FIRE STOP DRYER VENT @ TOP PLATE - - PROVIDE PFH PORTAL FRAMING PER PLAN - -PROVIDE 800 LB HOLD DOWN DEVICE EC#2 PER PLAN - - PROVIDE ANCHOR BOLTS @ SCH 40 COLUMN UNDER STAIRS - - PROVIDE SOLID BLOCK @ 24" O. C. FIRST 3 JOIST BAYS WHERE JOIST RUN PARALLEL TO FOUNDATION WALL PER PLAN - - SEAL UPWARD PENETRATIONS BATH #2 , BED #2 , ENTRY CLOSET, MASTER VANITY, REFRIGEERATOR, - - SEAL BATH EXHAUST WITH METALLIC TAPE -
All Rough Inspection - Residential Passed 5/18/2020 5/18/2020 05/18/2020
Misc
Resolved
05/18/2020
Driveway Inspection Partial 6/1/2020 (P.M.) 6/1/2020 06/01/2020
Misc
Informational
06/01/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 6/5/2020 6/5/2020 06/09/2020
Misc
Informational
06/01/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Occupancy Inspection - Codes Residential Failed 9/18/2020 9/18/2020 09/18/2020
Misc
Corrective Action Required
09/18/2020
- GFCI protection required at front bath receptacle - Label dedicated outlet in garage as not GFCI protected - Seal all penetrations in siding, seal along top of AC disconnect - Remove sod cover blocking storm sewer inlet(s) at swale backyard - Place splash blocks at all downspout and sump pump discharge locations, minimum distance 36” from foundation - Obtain lawn irrigation system permit
Occupancy Inspection - Codes Residential Failed 9/23/2020 9/23/2020 09/23/2020
Misc
Corrective Action Required
09/18/2020
- GFCI protection required at front bath receptacle - Label dedicated outlet in garage as not GFCI protected
Plot Plan Inspection Passed 09/23/2020
Occupancy Inspection - Codes Residential Full C of O 9/25/2020 9/25/2020 09/25/2020
Misc
Resolved
09/25/2020
Documents & Images
Date Uploaded File Type Document Name
11/04/2019 Receipt Receipt for transaction: 2019-007147
11/04/2019 Letter DS Building Permit
11/05/2019 Plot Plan DOC110519-11052019114611
12/13/2019 Letter INSPECTION SUMMARY
02/11/2020 Letter INSPECTION SUMMARY
02/11/2020 Letter INSPECTION SUMMARY
02/24/2020 Letter INSPECTION SUMMARY
03/02/2020 Letter INSPECTION SUMMARY
05/14/2020 Letter INSPECTION SUMMARY
05/14/2020 Letter INSPECTION SUMMARY
05/14/2020 Letter INSPECTION SUMMARY
05/14/2020 Letter INSPECTION SUMMARY
05/18/2020 Letter INSPECTION SUMMARY
06/01/2020 Letter INSPECTION SUMMARY
06/09/2020 Letter INSPECTION SUMMARY
08/31/2020 Receipt Receipt for transaction:2020-005852
09/18/2020 Letter INSPECTION SUMMARY
09/23/2020 Letter INSPECTION SUMMARY
09/23/2020 Letter INSPECTION SUMMARY
09/25/2020 Letter Field Certificate of Occupancy
09/25/2020 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home