Permit Application Status

PRRES20193102


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20193102
Building Permit - Residential
Certificate of Occupancy
CMH PARKS INC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED PATIO
10/22/2019
11/04/2019
11/18/2020
Locations
Contacts
CMH PARKS INC, Address:5000 CLAYTON RD  
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
KIMBEL MECHANICAL SYSTEMS, INC, Address:1936 N SHILOH DR, Phone:(479) 756-1099  
DUSTIN@SUMMITHOMESKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 10/24/2019 11/01/2019
Kim Brennan
Residential Plan Review Approved 10/24/2019 10/22/2019
Kim Brennan
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
10/22/2019

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315) No smoke detector shown on the main level
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,152.86 $1,152.86 Paid 11/04/2019
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 11/04/2019
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 11/04/2019
8331504-EFHB Middle Big Creek, Full $569.16 $569.16 Paid 11/04/2019
8331507-Sewer Connection Fee $510.00 $510.00 Paid 11/04/2019
8331401-Water Tap Fee $3,477.00 $3,477.00 Paid 11/04/2019
8350015-Water Meter Fee $425.02 $425.02 Paid 11/04/2019
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 12/13/2019 (11:30) 12/13/2019 12/13/2019
Underslab Plumbing Inspection - Residential Failed 2/3/2020 2/3/2020 02/03/2020
Misc
Corrective Action Required
02/03/2020
- Interior drain tile not completed around foundation footing
Sewer Service Inspection - R Passed 2/10/2020 (1:00) 2/10/2020 02/10/2020
Water Service Inspection - R Passed 2/11/2020 02/11/2020
Underslab Plumbing Inspection - Residential Failed 2/14/2020 2/14/2020 02/14/2020
Misc
Corrective Action Required
02/03/2020
- Interior drain tile not completed around foundation footing and connected back to sump basin
Underslab Plumbing Inspection - Residential Passed 2/19/2020 2/19/2020 02/19/2020
Misc
Resolved
02/19/2020
Piers/Caissons Inspection - Residential Passed 4/3/2020 (8:45) 4/3/2020 04/03/2020
Misc
Informational
04/03/2020
(2) 24 X 36 COVERED DECK PIERS
Electrical Service Inspection Passed 5/7/2020 5/7/2020 05/07/2020
Gas Piping Inspection - Residential Passed 5/7/2020 5/7/2020 05/07/2020
Gas Service Inspection - Residential Passed 5/7/2020 5/7/2020 05/07/2020
Erosion Control Inspection Residential Failed 5/7/2020 05/07/2020
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
05/07/2020
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE - - CLEAN STREET -
All Rough Inspection - Residential Failed 5/7/2020 5/7/2020 05/07/2020
Miscellaneous Correction
Corrective Action Required
05/07/2020
- PROVIDE HANGERS PER TRUSS LAYOUT SCHEDULE - - BLOCK SHEATHING BREAK ABOVE SINGLE CAR GARAGE - - OPEN PORCH LID TO EXPOSE HANGERS - - PROVIDE H 2.5S TRUSSES ABOVE FRONT DOOR/ STAIRWAY - - PROVIDE 800 LB HOLD DOWNS EC#2 PER PLAN - - COMPLETE FURR DOWNS GARAGE & GREAT ROOM - - PROVIDE PFH PORTAL FRAME GARAGE DOOR PER PLAN - - PROVIDE FLASHING HORIZONTAL TRIM ABOVE GARAGE - - NAIL SHEATHING AT FRONT PORCH WITH 8D NAILS PER PLAN NOT STAPLES PENETRATIONS IN TYVEK NEED TAPED WITH TYVEK TAPE - - PROVIDE PLUMBING NAIL GUARD LAUNDRY ROOM -
All Rough Inspection - Residential Failed 05/07/2020
Miscellaneous Correction
Corrective Action Required
05/07/2020
- PROVIDE HANGERS PER TRUSS LAYOUT SCHEDULE - - BLOCK SHEATHING BREAK ABOVE SINGLE CAR GARAGE - - OPEN PORCH LID TO EXPOSE HANGERS - - PROVIDE H 2.5S TRUSSES ABOVE FRONT DOOR/ STAIRWAY - - PROVIDE 800 LB HOLD DOWNS EC#2 PER PLAN - - COMPLETE FURR DOWNS GARAGE & GREAT ROOM - - PROVIDE PFH PORTAL FRAME GARAGE DOOR PER PLAN - - PROVIDE FLASHING HORIZONTAL TRIM ABOVE GARAGE - - NAIL SHEATHING AT FRONT PORCH WITH 8D NAILS PER PLAN NOT STAPLES PENETRATIONS IN TYVEK NEED TAPED WITH TYVEK TAPE - - PROVIDE PLUMBING NAIL GUARD LAUNDRY ROOM -
All Rough Inspection - Residential Failed 5/11/2020 5/11/2020 05/11/2020
Miscellaneous Correction
Corrective Action Required
05/07/2020
- BLOCK SHEATHING BREAK ABOVE SINGLE CAR GARAGE - - OPEN PORCH LID TO EXPOSE HANGERS - - PROVIDE 800 LB HOLD DOWNS EC#2 PER PLAN - - PROVIDE PFH PORTAL FRAME GARAGE DOOR PER PLAN - - NAIL SHEATHING AT FRONT PORCH WITH 8D NAILS PER PLAN
All Rough Inspection - Residential Failed 5/14/2020 5/14/2020 05/14/2020
Miscellaneous Correction
Corrective Action Required
05/11/2020
- TRUSS HANGERS PER PLANS AT FRONT PORCH - - PROVIDE PFH PORTAL FRAME GARAGE DOOR PER PLAN - TENSION STRAPS MISSING
All Rough Inspection - Residential Failed 5/15/2020 5/15/2020 05/15/2020
Miscellaneous Correction
Corrective Action Required
05/14/2020
- PROVIDE PFH PORTAL FRAME GARAGE DOOR PER PLAN - COMPLETE TENSION STRAP NAIL PATTERN PER MANUFACTURER
All Rough Inspection - Residential Passed 05/15/2020
Miscellaneous Correction
Resolved
05/15/2020
Driveway Inspection Partial 6/1/2020 (P.M.) 6/1/2020 06/01/2020
Misc
Informational
06/01/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 6/5/2020 6/5/2020 06/09/2020
Misc
Informational
06/01/2020
PRE POUR INSPECTION The forms are set and there appears to be sufficient compacted aggregate.
Occupancy Inspection - Codes Residential Failed 8/24/2020 8/24/2020 08/24/2020
Misc
Corrective Action Required
08/24/2020
- Security screws, provide (2) 3” screws each exterior hinge and strike plate at back door and hinge side front door - GFCI protection required at laundry receptacle - Cover plate at laundry receptacle required - Secure vanity lights to wall in master bath - Obtain lawn irrigation system permit - Place splashblocks at all downspout and sump pump discharge locations for minimum distance from foundation 36”
Plot Plan Inspection Passed 08/24/2020
Occupancy Inspection - Codes Residential Full C of O 11/18/2020 11/18/2020 11/18/2020
Misc
Resolved
11/18/2020
Documents & Images
Date Uploaded File Type Document Name
10/22/2019 Letter Codes Residential Plan Review
11/04/2019 Receipt Receipt for transaction: 2019-007148
11/04/2019 Letter DS Building Permit
11/05/2019 Plot Plan DOC110519-11052019114619
12/13/2019 Letter INSPECTION SUMMARY
02/03/2020 Letter INSPECTION SUMMARY
02/10/2020 Letter INSPECTION SUMMARY
02/11/2020 Letter INSPECTION SUMMARY
02/14/2020 Letter INSPECTION SUMMARY
02/19/2020 Letter INSPECTION SUMMARY
04/03/2020 Letter INSPECTION SUMMARY
05/07/2020 Letter INSPECTION SUMMARY
05/07/2020 Letter INSPECTION SUMMARY
05/07/2020 Letter INSPECTION SUMMARY
05/07/2020 Letter INSPECTION SUMMARY
05/07/2020 Letter INSPECTION SUMMARY
05/11/2020 Letter INSPECTION SUMMARY
05/14/2020 Letter INSPECTION SUMMARY
05/15/2020 Letter INSPECTION SUMMARY
05/15/2020 Letter INSPECTION SUMMARY
06/01/2020 Letter INSPECTION SUMMARY
06/09/2020 Letter INSPECTION SUMMARY
08/24/2020 Letter INSPECTION SUMMARY
08/24/2020 Letter INSPECTION SUMMARY
11/18/2020 Letter Field Certificate of Occupancy
11/18/2020 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home