Permit Application Status

PRRES20190113


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20190113
Building Permit - Residential
Certificate of Occupancy
ACH DEVELOPMENT LLC
NEW SINGLE FAMILY
NEW HOUSE COVERED DECK UNIFINSHED BASEMENT
01/18/2019
02/12/2019
08/13/2019
Locations
Contacts
ACH DEVELOPMENT LLC, Address:3170 NE CARNEGIE DR STE 400  
MCGRAW HOMES INC, Address:902 SE WILLOW PL, Phone:(816) 985-6909  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
UNITED ELECTRIC COMPANY, Address:PO BOX 723, Phone:(816) 795-2744  
A BRIGHT PLUMBING LLC, Address:18107 E 18TH TER N, Phone:(816) 215-0730  
chad@mcgraw-homes.com  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 01/23/2019 01/28/2019
Steve Conrick
Basement egress
Corrective Action Required
01/23/2019

Basement egress location(s) and elevation of the lowest adjacent grade must be provided on the plot plan. ***Egress wells are not shown in zoomed viewport***
Basement elevation
Corrective Action Required
01/23/2019

The Basement floor elevation and basement type (e.g. full/standard, daylight, walk-out, etc.) ***The MDP calls for a daylight on lot 328. The plot plan calls out a daylight, but shows a walk out with LAG. Please clearify and submit a letter from Matt S. if there is a change in basement type***
Residential Plan Review Approved 01/23/2019 01/28/2019
Brandon Kalwei
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,356.12 $1,356.12 Paid 02/12/2019
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 02/12/2019
8331507-Sewer Connection Fee $390.00 $390.00 Paid 02/12/2019
8331401-Water Tap Fee $3,409.00 $3,409.00 Paid 02/12/2019
8350015-Water Meter Fee $408.37 $408.37 Paid 02/12/2019
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 2/13/2019 (10:30) 2/13/2019 at 11:40 AM 02/13/2019
Underslab Plumbing Inspection - Residential Passed 3/8/2019 3/8/2019 at 8:20 AM 03/08/2019
Sewer Service Inspection - R Passed 3/8/2019 3/8/2019 03/08/2019
Water Service Inspection - R Partial 3/8/2019 03/08/2019
Water Service Inspection - R Passed 4/17/2019 (8:15) 4/17/2019 04/17/2019
All Rough Inspection - Residential Failed 5/3/2019 5/3/2019 at 9:15 AM 05/03/2019
Misc
Corrective Action Required
05/03/2019
FRAMING: -Provide full bearing for lvl beam at master shower exterior wall -Install ceiling joist hangers at lvl connections outside rear bedroom -Install hangers for lvl-lvl connections at stair -Engineer to address beam under kitchen bearing wall -CS-PF walls required at rear dining exterior wall ELECTRICAL: -Protect wiring at double stud near range MECHANICAL: -Use proper fireblocking material to isolate electrical inside return air space -Complete installing water heater flue **OK TO INSULATE
Electrical Service Inspection Passed 5/3/2019 5/3/2019 05/03/2019
Gas Service Inspection - Residential Passed 5/3/2019 5/3/2019 05/03/2019
All Rough Inspection - Residential Failed 5/8/2019 5/8/2019 at 8:25 AM 05/08/2019
Misc
Corrective Action Required
05/03/2019
FRAMING: -CS-PF walls required at rear dining exterior wall **strap header MECHANICAL: -Complete installing water heater flue **install insulation shield
All Rough Inspection - Residential Passed 5/9/2019 5/9/2019 at 9:15 AM 05/09/2019
Misc
Resolved
05/09/2019
FRAMING: -CS-PF walls required at rear dining exterior wall **strap header
Piers/Caissons Inspection - Residential Passed 6/25/2019 (8:00) 6/25/2019 at 9:45 AM 06/25/2019
Sidewalk Inspection Passed 6/24/2019 (P.M.) 6/24/2019 06/28/2019
Misc
Informational
06/24/2019
Sidewalk pre-inspection passed .
Misc
Informational
06/28/2019
Sidewalk passed final inspection .
Driveway Inspection Passed 6/24/2019 (P.M.) 6/24/2019 06/28/2019
Misc
Informational
06/24/2019
Driveway pre- inspection passed .
Misc
Informational
06/28/2019
Driveway - passed final inspection .
Occupancy Inspection - Codes Residential Failed 7/30/2019 7/30/2019 at 4:40 PM 07/30/2019
Misc
Corrective Action Required
07/30/2019
NEC 370-20; IRC E3806.5-6 SET-BACK OF ELECTRICAL RECEPTACLE / SWITCH BOXES: 1/4" MAXIMUM SET-BACK @ NON-COMBUSTIBLE SURFACES. SEE AT KITCHEN BACKSPLASH
Misc
Corrective Action Required
07/30/2019
LSCO #5029 PERMANENT EROSION CONTROL, VEGETATION, & DRAINAGE GRADING PER PLOT PLAN: POSITIVE DRAINAGE ENTIRE LOT FINE GRADE, SOD/SEED LOT; 6" MIN CLEARANCE TO WOOD FRAMING, SHEATHING, SIDING, TRIM, STUCCO; UTILITY STRUCTURES AND ACCESS PLUGS/COVERS SET TO FINISH GRADE; SEWER SERVICE TRACER PORT AT GRADE;..
Misc
Corrective Action Required
07/30/2019
TEMPORARY EROSION CONTROL REQUIRED -- FRONT AND REAR -- FOR TCO
Occupancy Inspection - Codes Residential Failed 7/30/2019 07/30/2019
Misc
Corrective Action Required
07/30/2019
NEC 370-20; IRC E3806.5-6 SET-BACK OF ELECTRICAL RECEPTACLE / SWITCH BOXES: 1/4" MAXIMUM SET-BACK @ NON-COMBUSTIBLE SURFACES. SEE AT KITCHEN BACKSPLASH
Misc
Corrective Action Required
07/30/2019
LSCO #5029 PERMANENT EROSION CONTROL, VEGETATION, & DRAINAGE GRADING PER PLOT PLAN: POSITIVE DRAINAGE ENTIRE LOT FINE GRADE, SOD/SEED LOT; 6" MIN CLEARANCE TO WOOD FRAMING, SHEATHING, SIDING, TRIM, STUCCO; UTILITY STRUCTURES AND ACCESS PLUGS/COVERS SET TO FINISH GRADE; SEWER SERVICE TRACER PORT AT GRADE;..
Misc
Corrective Action Required
07/30/2019
TEMPORARY EROSION CONTROL REQUIRED -- FRONT AND REAR -- FOR TCO
SEC. 7-1408.1 HINGES
Corrective Action Required
07/30/2019
Hinges for exterior swinging doors shall comply with the following: A. At least two (2) wood screws, three inches (3”) in length, penetrating at least one inch (1”) into wall structure shall be used. Solid wood fillers or shims shall be used to eliminate any space between the wall structure and door frame behind each hinge. Exception: Hinges within a door frame installed directly adjacent to a sidelight. B. Hinges for out-swinging doors shall be equipped with mechanical interlock to preclude the removal of the door from the exterior.
Occupancy Inspection - Codes Residential Temporary C of O 8/1/2019 8/1/2019 at 10:40 AM 08/01/2019
Misc
Resolved
08/01/2019
NEC 370-20; IRC E3806.5-6 SET-BACK OF ELECTRICAL RECEPTACLE / SWITCH BOXES: 1/4" MAXIMUM SET-BACK @ NON-COMBUSTIBLE SURFACES. SEE AT KITCHEN BACKSPLASH
Misc
Corrective Action Required
07/30/2019
LSCO #5029 PERMANENT EROSION CONTROL, VEGETATION, & DRAINAGE GRADING PER PLOT PLAN: POSITIVE DRAINAGE ENTIRE LOT FINE GRADE, SOD/SEED LOT; 6" MIN CLEARANCE TO WOOD FRAMING, SHEATHING, SIDING, TRIM, STUCCO; UTILITY STRUCTURES AND ACCESS PLUGS/COVERS SET TO FINISH GRADE; SEWER SERVICE TRACER PORT AT GRADE;..
Misc
Resolved
08/01/2019
TEMPORARY EROSION CONTROL REQUIRED -- FRONT AND REAR -- FOR TCO
SEC. 7-1408.1 HINGES
Resolved
08/01/2019
Hinges for exterior swinging doors shall comply with the following: A. At least two (2) wood screws, three inches (3”) in length, penetrating at least one inch (1”) into wall structure shall be used. Solid wood fillers or shims shall be used to eliminate any space between the wall structure and door frame behind each hinge. Exception: Hinges within a door frame installed directly adjacent to a sidelight. B. Hinges for out-swinging doors shall be equipped with mechanical interlock to preclude the removal of the door from the exterior.
Occupancy Inspection - Codes Residential Full C of O 8/13/2019 8/13/2019 at 8:30 AM 08/13/2019
Misc
Resolved
08/13/2019
LSCO #5029 PERMANENT EROSION CONTROL, VEGETATION, & DRAINAGE GRADING PER PLOT PLAN: POSITIVE DRAINAGE ENTIRE LOT FINE GRADE, SOD/SEED LOT; 6" MIN CLEARANCE TO WOOD FRAMING, SHEATHING, SIDING, TRIM, STUCCO; UTILITY STRUCTURES AND ACCESS PLUGS/COVERS SET TO FINISH GRADE; SEWER SERVICE TRACER PORT AT GRADE;..
Documents & Images
Date Uploaded File Type Document Name
01/18/2019 Letter Codes Residential Plan Review
01/23/2019 Letter Codes Residential Plan Review
02/12/2019 Receipt Receipt for transaction: 2019-000452
02/12/2019 Letter Codes Building Permit
02/13/2019 Letter INSPECTION SUMMARY
02/14/2019 Engineer Report/Study DOC021319-02132019160717
02/14/2019 Plot Plan DOC021319-02132019160730
03/08/2019 Letter INSPECTION SUMMARY
03/08/2019 Letter INSPECTION SUMMARY
03/08/2019 Letter INSPECTION SUMMARY
04/17/2019 Letter INSPECTION SUMMARY
04/17/2019 Letter INSPECTION SUMMARY
05/03/2019 Letter INSPECTION SUMMARY
05/03/2019 Letter INSPECTION SUMMARY
05/03/2019 Letter INSPECTION SUMMARY
05/08/2019 Letter INSPECTION SUMMARY
05/09/2019 Letter INSPECTION SUMMARY
06/24/2019 Letter INSPECTION SUMMARY
06/24/2019 Letter INSPECTION SUMMARY
06/25/2019 Letter INSPECTION SUMMARY
06/28/2019 Letter INSPECTION SUMMARY
06/28/2019 Letter INSPECTION SUMMARY
06/28/2019 Letter INSPECTION SUMMARY
06/28/2019 Letter INSPECTION SUMMARY
07/30/2019 Letter INSPECTION SUMMARY
08/01/2019 Letter Codes Temporary Certificate of Occupancy
08/13/2019 Letter Codes Final Certificate of Occupancy
08/13/2019 Letter Field Certificate of Occupancy
08/14/2019 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home