Summary
PRRES20183588
Building Permit - Residential
Certificate of Occupancy
HUNT MIDWEST RESIDENTIAL LLC
NEW SINGLE FAMILY
NEW HOUSE COVERED DECK UNFINISHED BASEMENT
10/17/2018
10/25/2018
05/24/2019
Locations
Contacts
HUNT MIDWEST RESIDENTIAL LLC, Address:8300 NE UNDERGROUND DR  
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
KIMBEL MECHANICAL SYSTEMS, INC, Address:1936 N SHILOH DR, Phone:(479) 756-1099  
GREG@SUMMITHOMESKC.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 10/19/2018 10/25/2018
Development Center
As-graded plot plan
Corrective Action Required
10/19/2018

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy. ***Please add "AS-GRADED PLOT PLAN IS REQUIRED PRIOR TO SODDING" in a bubble***
Residential Plan Review Approved 10/19/2018 10/18/2018
Brandon Kalwei
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $978.69 $978.69 Paid 10/25/2018
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 10/25/2018
8331507-Sewer Connection Fee $360.00 $360.00 Paid 10/25/2018
8331401-Water Tap Fee $3,409.00 $3,409.00 Paid 10/25/2018
8350015-Water Meter Fee $408.37 $408.37 Paid 10/25/2018
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Sewer Service Inspection - R Passed 12/5/2018 12/5/2018 at 11:31 AM 12/05/2018
Water Service Inspection - R Passed 12/5/2018 12/5/2018 at 11:40 AM 12/05/2018
Underslab Plumbing Inspection - Residential Not Ready 12/10/2018 12/10/2018 12/10/2018
Misc
Corrective Action Required
12/10/2018
-no Footing inspection on file. - no erosion control - no address. no further inspections untill footing is approved, erosion control is in place and approved, address posted & street is cleaned.
Underslab Plumbing Inspection - Residential Passed 12/13/2018 12/13/2018 12/13/2018
Misc
Resolved
12/13/2018
-no Footing inspection on file. - no erosion control - no address. no further inspections untill footing is approved, erosion control is in place and approved, address posted & street is cleaned.
Footing Inspection - Residential Passed 11/16/2018 12/13/2018
Electrical Service Inspection Passed 2/11/2019 2/11/2019 at 8:00 AM 02/11/2019
Gas Piping Inspection - Residential Passed 2/11/2019 2/11/2019 at 8:30 AM 02/11/2019
Gas Service Inspection - Residential Passed 2/11/2019 2/11/2019 at 8:40 AM 02/11/2019
All Rough Inspection - Residential Failed 2/11/2019 2/11/2019 at 7:00 AM 02/11/2019
Misc
Corrective Action Required
02/11/2019
EROSION CONTRL REQUIRED FRONT AND REAR. -anchor bsmt beam post -install plate bolts where required at exterior bsmt walls. - firestop flue chase 1st floor from bsmt and into attic. - provide engineers report on truss bearing garage wall. wall is 3" off set from end of truss. - install required plate bolts at front garage portal walls. - install bsmt windows
All Rough Inspection - Residential Failed 2/14/2019 2/14/2019 02/14/2019
Misc
Corrective Action Required
02/11/2019
EROSION CONTRL REQUIRED FRONT AND REAR. NO EROSION COONTROL ADDRESSED. -install plate bolts where required at exterior bsmt walls. REMOVE INSULATION FOR INSPECTION.
Driveway Inspection Partial 4/2/2019 4/2/2019 04/02/2019
Misc
Informational
04/02/2019
PRE POUR INSPECTION The forms are up and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 4/9/2019 04/11/2019
Misc
Informational
04/02/2019
PRE POUR INSPECTION The forms are up and there appears to be sufficient compacted aggregate.
Occupancy Inspection - Codes Residential Failed 4/16/2019 4/16/2019 04/16/2019
Misc
Corrective Action Required
04/16/2019
- Quick vent not approved under kitchen sink ,use approved air admittance vent. - install Dishwasher - install stove -secure attic access -dbl 2x10 on deck over span. -Final grade, splash blocks, sod, erosion control. - caulk all siding penetrations. - complete sump pump discharge.
All Rough Inspection - Residential Passed 4/16/2019 4/16/2019 04/16/2019
Misc
Resolved
04/16/2019
EROSION CONTRL REQUIRED FRONT AND REAR. NO EROSION COONTROL ADDRESSED. -install plate bolts where required at exterior bsmt walls. REMOVE INSULATION FOR INSPECTION.
Occupancy Inspection - Codes Residential Not Ready 5/15/2019 5/15/2019 05/15/2019
Misc
Corrective Action Required
04/16/2019
- Quick vent not approved under kitchen sink ,use approved air admittance vent. - install Dishwasher - install stove -secure attic access -dbl 2x10 on deck over span. -Final grade, splash blocks, sod, erosion control. - caulk all siding penetrations. - complete sump pump discharge.
Misc
Corrective Action Required
05/15/2019
locked no door code and no email about vent . black quicky vents are not appoved just FYI
Occupancy Inspection - Codes Residential Temporary C of O 5/20/2019 5/20/2019 05/20/2019
Misc
Corrective Action Required
05/15/2019
-dbl 2x10 on deck over span. -Final grade, splash blocks, sod, erosion control.
Misc
Corrective Action Required
05/15/2019
Occupancy Inspection - Codes Residential Full C of O 5/24/2019 5/24/2019 05/24/2019
Misc
Resolved
05/24/2019
-dbl 2x10 on deck over span. -Final grade, splash blocks, sod, erosion control.
Misc
Resolved
05/24/2019
Plot Plan Inspection Failed 5/30/2019 06/06/2019
Documents & Images
Date Uploaded File Type Document Name
10/17/2018 Letter Codes Residential Plan Review
10/19/2018 Letter Codes Residential Plan Review
10/25/2018 Receipt Receipt for transaction: 2018-006997
10/25/2018 Letter Codes Building Permit
10/30/2018 Plot Plan DOC102918-10292018155950
12/05/2018 Letter INSPECTION SUMMARY
12/05/2018 Letter INSPECTION SUMMARY
12/10/2018 Letter INSPECTION SUMMARY
12/13/2018 685 eagle creek footing verification
04/02/2019 Letter INSPECTION SUMMARY
04/11/2019 Letter INSPECTION SUMMARY
05/15/2019 Letter INSPECTION SUMMARY
05/20/2019 Letter INSPECTION SUMMARY
05/20/2019 Letter Codes Temporary Certificate of Occupancy
05/24/2019 Letter Field Certificate of Occupancy
06/06/2019 Letter INSPECTION SUMMARY
06/14/2019 Letter Codes Final Certificate of Occupancy
11/01/2019 LOT 685 ASBUILT NEW
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home