HUNT MIDWEST RESIDENTIAL LLC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK
10/15/2018
10/23/2018
10/03/2019
Locations
Contacts
HUNT MIDWEST RESIDENTIAL LLC, Address:8300 NE UNDERGROUND DR  
SAB CONSTRUCTION INC, Address:PO BOX 942, Phone:(816) 524-3855  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
C-R ELECTRICAL LLC, Address:4539 RIDGEWAY, Phone:(816) 803-3500  
GARRISON PLUMBING, Address:15430 S MAHAFFIE ST STE 102, Phone:(913) 768-1311  
JIM@SABHOMES.COM  
Reviews
Review Type Outcome Est. Completion Date Completed
Residential Plan Review Approved 10/17/2018 10/22/2018
Kim Brennan
05 Provide square footage of living area, garage area, unfinished basement
Corrective Action Required
10/15/2018

Provide square footage of living area, garage area, unfinished basement area, etc (IRC Section R304) no square footage shown for finished and unfinished basement
08 Designate locations of smoke detectors and carbon monoxide detectors
Corrective Action Required
10/15/2018

Designate locations of smoke detectors and carbon monoxide detectors. (IRC Section R314 and R315) none shown in bedrooms or immediate vicinity outside of bedrooms.
37 Provide details for any walls over 10 feet in height.
Corrective Action Required
10/15/2018

Provide details for any walls over 10 feet in height. Include stud grade, size, spacing and actual, uninterrupted height. (IRC Section 602.3.1 and Table 602.3(5) & 602.3.1) does not specify uninterrupted height
Plot Plan Review Approved 10/17/2018 10/16/2018
Steve Conrick
As-graded plot plan
Corrective Action Required
10/16/2018

A as-graded plot plan per Section 7-160, Code of Ordinances, is required prior to occupancy. ***Please provide "AS-GRADED PLOT PLAN IS REQUIRED PRIOR TO SODDING" in a bubble***
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,358.48 $1,358.48 Paid 10/23/2018
9110073-Right of Way Permit Fee $80.00 $80.00 Paid 10/23/2018
8331507-Sewer Connection Fee $600.00 $600.00 Paid 10/23/2018
8331401-Water Tap Fee $3,409.00 $3,409.00 Paid 10/23/2018
8350015-Water Meter Fee $408.37 $408.37 Paid 10/23/2018
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 10/31/2018 (11:30) 10/31/2018 at 11:30 AM 10/31/2018
Sewer Service Inspection - R Passed 11/12/2018 (1:00) 11/12/2018 11/12/2018
Water Service Inspection - R Passed 11/13/2018 11/13/2018
Underslab Plumbing Inspection - Residential Passed 12/19/2018 12/19/2018 12/19/2018
All Rough Inspection - Residential Failed 3/19/2019 3/19/2019 at 10:35 AM 03/19/2019
Misc
Corrective Action Required
03/19/2019
-provide plans for inspection. - erosion control in the front and clean streets -Plate bolt nut & washer south side garage dbl door. -vent all bath fans. -firestop flue chase garage wall. fire stop den/ garage wall at thermostat location from vertical to horizontal. - secure was line at fire place location. -plumbing protection at top plate den/ garagae wall at top plate. -support valley rafter to mstr bed wall over stairs. -check rafter span over rear 2 bedrooms. loading of vaulted ceiling rafters. -fire stop fur down chase right side of panel basement wall, fur down at I beam rear bsmt bed. -provide vent for basement bar sink , code method of venting.
Electrical Service Inspection Passed 3/19/2019 3/19/2019 at 9:00 AM 03/19/2019
Gas Service Inspection - Residential Passed 3/19/2019 3/19/2019 at 9:35 AM 03/19/2019
All Rough Inspection - Residential Passed 3/27/2019 3/27/2019 03/27/2019
Misc
Resolved
03/27/2019
-provide plans for inspection. - erosion control in the front and clean streets -Plate bolt nut & washer south side garage dbl door. -vent all bath fans. -firestop flue chase garage wall. fire stop den/ garage wall at thermostat location from vertical to horizontal. - secure was line at fire place location. -plumbing protection at top plate den/ garagae wall at top plate. -support valley rafter to mstr bed wall over stairs. -check rafter span over rear 2 bedrooms. loading of vaulted ceiling rafters. -fire stop fur down chase right side of panel basement wall, fur down at I beam rear bsmt bed. -provide vent for basement bar sink , code method of venting.
Driveway Inspection Partial 5/15/2019 5/15/2019 05/15/2019
Misc
Informational
05/15/2019
PRE POUR INSPECTION The forms are up and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 5/22/2019 05/23/2019
Misc
Informational
05/15/2019
PRE POUR INSPECTION The forms are up and there appears to be sufficient compacted aggregate.
Occupancy Inspection - Codes Residential Temporary C of O 6/28/2019 06/28/2019
Misc
Corrective Action Required
06/28/2019
sod, erosion control( sod in a few days) water meter , final grade etc.
Occupancy Inspection - Codes Residential Full C of O 10/3/2019 10/3/2019 10/03/2019
Misc
Resolved
10/03/2019
sod, erosion control( sod in a few days) water meter , final grade etc.
Documents & Images
Date Uploaded File Type Document Name
10/15/2018 Letter Codes Residential Plan Review
10/23/2018 Receipt Receipt for transaction: 2018-006945
10/23/2018 Letter Codes Building Permit
10/24/2018 Plot Plan DOC102418-10242018100348
10/31/2018 Letter Inspection Summary
11/12/2018 Letter Inspection Summary
11/13/2018 Letter INSPECTION SUMMARY
12/19/2018 Letter INSPECTION SUMMARY
03/19/2019 Letter INSPECTION SUMMARY
03/27/2019 Letter INSPECTION SUMMARY
05/15/2019 Letter INSPECTION SUMMARY
05/23/2019 Letter INSPECTION SUMMARY
06/28/2019 Letter Codes Temporary Certificate of Occupancy
10/03/2019 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home