Permit Application Status

PRRES20181760


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20181760
Building Permit - Residential
Certificate of Occupancy
JFE CONSTRUCTION INC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK
06/08/2018
06/18/2018
04/12/2019
Locations
Contacts
JFE CONSTRUCTION INC, Address:1314 SW MARKET ST, Phone:(816) 470-0074  
A & D HEATING AND COOLING INC, Address:2006 W MAIN ST, Phone:(816) 537-7952  
MOOSE ELECTRICAL CONSTRUCTION LLC, Address:105 HARLEQUIN DR, Phone:(816) 682-2693  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
JFE CONSTRUCTION INC, Address:1314 SW MARKET ST  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 06/13/2018 06/14/2018
Steve Conrick
Residential Plan Review Approved 06/12/2018 06/08/2018
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $850.28 $850.28 Paid 06/18/2018
9110073-Right of Way Permit Fee $75.00 $75.00 Paid 06/18/2018
8331507-Sewer Connection Fee $420.00 $420.00 Paid 06/18/2018
8331401-Water Tap Fee $3,343.00 $3,343.00 Paid 06/18/2018
8350015-Water Meter Fee $431.83 $431.83 Paid 06/18/2018
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 7/3/2018 7/3/2018 at 7:30 AM 07/03/2018
Sewer Service Inspection - R Passed 7/12/2018 (2:30) 7/12/2018 at 2:00 PM 07/17/2018
Underslab Plumbing Inspection - Residential Passed 7/17/2018 7/17/2018 at 2:20 PM 07/17/2018
Water Service Inspection - R Passed 7/17/2018 7/17/2018 at 2:35 PM 07/17/2018
Piers/Caissons Inspection - Residential Passed 8/8/2018 (2:00) 8/8/2018 at 2:20 PM 08/08/2018
Electrical Service Inspection Passed 10/17/2018 10/17/2018 at 10:00 AM 10/17/2018
Gas Service Inspection - Residential Passed 10/17/2018 10/17/2018 at 10:15 AM 10/17/2018
All Rough Inspection - Residential Failed 10/17/2018 10/17/2018 at 10:30 AM 10/17/2018
Misc
Corrective Action Required
10/17/2018
-Missing double joist right of furnace. -Block cantilever at bedroom and bsmt bath, per plans. -Firestop fierpalce from attic -Security blocking rear bsmt door. -Firestop bsmt east wall 10' horizontal, fur down from joist space at bathroom and over bedroom window, -overcloset. -Solid block over Ibea, where shown on plans. -Connect bathfan east bsmt bath -Firestop Hole in bottom plate right of fire place -Missing Nuts and washer west side of garage bottom wall plates. -Firstop dead space back of shower 1st floor. -Strap rear header 1st floor see portal framing detail. -Nail all siding per code and portal wall framing.
All Rough Inspection - Residential Failed 10/23/2018 10/23/2018 at 10:00 AM 10/23/2018
Misc
Corrective Action Required
10/17/2018
-Firestop bsmt east wall 10' horizontal, fur down from joist space at bathroom and over bedroom window, -overcloset. FIRESTOP OVER FUR DOWN FROM JOSIT SPACE AT CEILING HEIGHT. ( bathroom bedrrom ceiling ,closet, over window ) BEDROOM WALL FIRE STOP 10' HORIZONTAL. between exterior and interior walls.
All Rough Inspection - Residential Failed 10/30/2018 10/30/2018 10/30/2018
Misc
Corrective Action Required
10/23/2018
-Firestop bsmt east wall 10' horizontal, fur down from joist space at bathroom and over bedroom window, -overcloset. FIRESTOP OVER FUR DOWN FROM JOSIT SPACE AT CEILING HEIGHT. ( bathroom bedrrom ceiling ,closet, over window )
All Rough Inspection - Residential Passed 10/30/2018
Misc
Resolved
10/30/2018
-Firestop bsmt east wall 10' horizontal, fur down from joist space at bathroom and over bedroom window, -overcloset. FIRESTOP OVER FUR DOWN FROM JOSIT SPACE AT CEILING HEIGHT. ( bathroom bedrrom ceiling ,closet, over window )
Driveway Inspection Partial 12/7/2018 12/10/2018 12/11/2018
Misc
Informational
12/11/2018
PRE POUR INSPECTION The forms are up and there appears to be sufficient compacted aggregate.
Driveway Inspection Passed 12/18/2018 12/18/2018
Misc
Informational
12/11/2018
PRE POUR INSPECTION The forms are up and there appears to be sufficient compacted aggregate.
Occupancy Inspection - Codes Residential Failed 2/14/2019 2/14/2019 02/14/2019
Misc
Corrective Action Required
02/14/2019
- exterior sod, erosion, splashblocks etc. -mstr AFCI does not trip. -install correct Floor outlet cover plates. -Seal garage door opener penetrations.
Occupancy Inspection - Codes Residential Temporary C of O 2/20/2019 2/20/2019 at 8:10 AM 02/20/2019
Misc
Corrective Action Required
02/14/2019
- exterior sod, erosion, splashblocks etc.
Occupancy Inspection - Codes Residential Full C of O 4/12/2019 4/12/2019 04/12/2019
Misc
Resolved
04/12/2019
- exterior sod, erosion, splashblocks etc.
Documents & Images
Date Uploaded File Type Document Name
06/18/2018 Receipt Receipt for transaction: 2018-003955
06/18/2018 Letter Codes Building Permit
06/18/2018 Plot Plan DOC061818-06182018133254
07/03/2018 Letter Inspection Summary
07/17/2018 Letter Inspection Summary
07/17/2018 Letter Inspection Summary
08/08/2018 Letter Inspection Summary
10/17/2018 Letter Inspection Summary
10/23/2018 Letter Inspection Summary
10/30/2018 Letter Inspection Summary
10/30/2018 Letter Inspection Summary
12/11/2018 Letter INSPECTION SUMMARY
12/18/2018 Letter DE-Daily Inspection Summary
02/14/2019 Letter INSPECTION SUMMARY
02/20/2019 Letter Codes Temporary Certificate of Occupancy
04/12/2019 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home