Summary
PRRES20181676
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE FINISHED AND UNFINISHED BASEMENT PATIO
06/01/2018
06/06/2018
05/15/2019
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
KIMBEL MECHANICAL SYSTEMS, INC, Address:1936 N SHILOH DR, Phone:(479) 756-1099  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
KIMBEL MECHANICAL SYSTEMS, INC, Address:1936 N SHILOH DR, Phone:(479) 756-1099  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 06/05/2018 06/06/2018
Steve Conrick
Property boundary
Corrective Action Required
06/05/2018

Property boundary distances and bearings, as shown on the recorded plat, must be provided on the plot plan. ***Rear yard bearing is flipped from what is shown on the plat***
Spot elevations
Corrective Action Required
06/05/2018

Spot elevations and/or drainage flow arrows shall be provided throughout the lot. ***Give high point elevation in rear yard and add spot elevations/contours to show how water will get around the house and/or flow with the rear yard swale***
Residential Plan Review Approved 06/05/2018 06/01/2018
Brandon Kalwei
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $824.96 $824.96 Paid 06/06/2018
8331504-EFHB Middle Big Creek, Full $401.76 $401.76 Paid 06/06/2018
8331507-Sewer Connection Fee $360.00 $360.00 Paid 06/06/2018
8331401-Water Tap Fee $3,343.00 $3,343.00 Paid 06/06/2018
8350015-Water Meter Fee $431.83 $431.83 Paid 06/06/2018
9110073-Right of Way Permit Fee $75.00 $75.00 Paid 06/06/2018
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 6/18/2018 6/18/2018 at 11:30 AM 06/18/2018
Sewer Service Inspection - R Passed 6/27/2018 at 8:55 AM 06/27/2018
Water Service Inspection - R Passed 7/2/2018 7/2/2018 at 12:25 PM 07/02/2018
Electrical Service Inspection Passed 8/16/2018 8/16/2018 at 1:00 PM 08/16/2018
Gas Piping Inspection - Residential Passed 8/16/2018 8/16/2018 at 1:10 PM 08/16/2018
Gas Service Inspection - Residential Passed 8/16/2018 8/16/2018 at 1:20 PM 08/16/2018
All Rough Inspection - Residential Failed 8/16/2018 8/16/2018 at 1:25 PM 08/16/2018
Misc
Corrective Action Required
08/16/2018
• garage portal sheathing not nailed at 3”oc • Fire stop electric at pantry • Fire stops nw great room corner • Protect nm wiring at steel beam in unfinished area in basement • Replace knockout at bottom of service panel • Fire stop at gas line to fire place • Turn clean out to face out to room in basement • * OK TO INSULATE*
All Rough Inspection - Residential Passed 8/20/2018 8/20/2018 at 10:00 AM 08/20/2018
Misc
Resolved
08/20/2018
• garage portal sheathing not nailed at 3”oc • Fire stop electric at pantry • Fire stops nw great room corner • Protect nm wiring at steel beam in unfinished area in basement • Replace knockout at bottom of service panel • Fire stop at gas line to fire place • Turn clean out to face out to room in basement • * OK TO INSULATE*
Driveway Inspection Partial 9/21/2018 9/21/2018 at 8:00 AM 09/21/2018
Informational
09/21/2018
Joe Starlin 09/21/2018 3:10 PM The driveway approach has been inspected, aggregate was compacted and the forms are set.
Sidewalk Inspection Partial 9/21/2018 at 8:25 AM 09/21/2018
Informational
09/21/2018
Joe Starlin 09/21/2018 3:50 PM Inspected the sidewalk, aggregate was compacted and forms set.
Sidewalk Inspection Passed 10/1/2018 at 9:00 AM 10/01/2018
PW-Misc
Informational
10/01/2018
Joe Starlin 10/01/2018 3:58 PM The sidewalk was inspected and is in compliance.
Driveway Inspection Passed 10/1/2018 at 9:15 AM 10/01/2018
Informational
10/01/2018
Joe Starlin 10/01/2018 4:00 PM The driveway was inspected and is in compliance.
Occupancy Inspection - Codes Residential Temporary C of O 11/28/2018 11/28/2018 at 2:20 PM 11/28/2018
Misc
Corrective Action Required
11/28/2018
* FINAL GRADE * SOD
Occupancy Inspection - Codes Residential Failed 1/28/2019 01/28/2019
Misc
Corrective Action Required
11/28/2018
* FINAL GRADE * SOD
Plot Plan Inspection Passed 5/15/2019 05/15/2019
Underslab Plumbing Inspection - Residential Passed 05/15/2019
Occupancy Inspection - Codes Residential Full C of O 5/15/2019 5/15/2019 at 7:30 AM 05/15/2019
Misc
Corrective Action Required
01/28/2019
* FINAL GRADE * SOD
Documents & Images
Date Uploaded File Type Document Name
06/05/2018 Letter Codes Residential Plan Review
06/06/2018 Receipt Receipt for transaction: 2018-003570
06/06/2018 Letter Codes Building Permit
06/07/2018 Plot Plan DOC060718-008
06/18/2018 Letter Inspection Summary
06/27/2018 Letter Inspection Summary
07/02/2018 Letter Inspection Summary
08/16/2018 Letter Inspection Summary
08/20/2018 Letter Inspection Summary
09/21/2018 Letter DE-Daily Inspection Summary
10/01/2018 Letter DE-Daily Inspection Summary
10/01/2018 Letter DE-Daily Inspection Summary
11/28/2018 Letter Codes Temporary Certificate of Occupancy
01/28/2019 Letter INSPECTION SUMMARY
05/15/2019 Letter INSPECTION SUMMARY
05/15/2019 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home