Summary
PRRES20173727
Building Permit - Residential
Final Completion
MUENSTERMANN JANET
REPAIR REPLACE UPGRADE
REPLACE SERVICE PANEL 200 AMP AND RE-WIRE AS NEEDED
11/14/2017
11/14/2017
03/26/2018
Locations
Contacts
MUENSTERMANN JANET, Address:50 SW 1501 RD  
COPELAND ELECTRICAL, Address:2520 LEES SUMMIT RD, Phone:(816) 461-3636  
Reviews
Review Type Outcome Est. Completion Date Completed
Licensed Contractors Approved 11/14/2017 11/14/2017
Development Center
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for Repair/Replace/Upgrade $30.00 $30.00 Paid 11/14/2017
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Electrical Service Inspection Passed 11/20/2017 11/20/2017 at 8:40 AM 11/20/2017
Rough Electrical Inspection - Residential Passed 11/20/2017 11/20/2017 at 8:55 AM 11/20/2017
Final Electrical Inspection - Residential Not Ready 3/15/2018 3/15/2018 at 4:40 PM 03/15/2018
Corrective Action Required
03/15/2018
FINAL INSPECTION ON ELECTRICAL PERMIT WILL BE PERFORMED AS PART OF FINAL INSPECTION ON ALL FOUR (GENERAL, ELECTRICAL, PLUMBING, HVAC) OUTSTANDING PERMITS. GENERAL CONTRACTOR APPLICANT PLEASE CONTACT DEVELOPMENT SERVICES AT 816-969-1200 TO REQUEST INSPECTION FOR FOLLOWING DAY WHEN ALL ARE VERIFIED READY FOR FINAL INSPECTION.
Final Electrical Inspection - Residential Failed 3/19/2018 at 10:40 AM 03/19/2018
E3802.5 Unfinished basement receptacles
Corrective Action Required
03/19/2018
GFCI PROTECTION. All 125-volt, single-phase, 15- and 20-ampere receptacles installed in unfinished basements shall have ground-fault circuit-interrupter protection for personnel.
E3902 RECEPTACLES
Corrective Action Required
03/19/2018
NEC 370-20; IRC E3806.5-6 SET-BACK OF ELECTRICAL RECEPTACLE / SWITCH BOXES: MUST BE FLUSH WITH COMBUSTIBLE WALL SURFACE. SEE RECEPT BOX ABOVE KITCHEN SINK 1/4" MAXIMUM SET-BACK @ NON-COMBUSTIBLE SURFACES. SEE RECEPT BOXES AT KITCHEN COUNTER BACKSPLASH.
Miscellaneous Correction
Corrective Action Required
03/19/2018
NEC 380-10; 410-56(f) / IRC E3901.10; E3902.6 SECURING OF ELECTRICAL RECEPTACLES / SWITCHES: SOME NOT SECURED SOLID TO BOX. ENSURE NONE ARE "SOFT" OR LOOSE SIDE-TO-SIDE. CHECK ALL AT SECOND FLOOR AND AT ATTIC/LOFT. USE YOKE SPACERS OR BOX EXTENDERS WHERE NEEDED.
Miscellaneous Correction
Corrective Action Required
03/19/2018
DESIGNATE THE TWO A/C CONDENSERS CIRCUITS AT ELECTRICAL SERVICE PANEL AND INSTALL BREAKERS COMPLIANT WITH MANUFACTURER LABELS ON CONDENSER UNITS. ONE IS 25A MAX; OTHER IS 30A MAX. CURRENTLY ONE BREAKER IS 60A.
Final Electrical Inspection - Residential Failed 3/23/2018 3/23/2018 at 10:10 AM 03/23/2018
E3802.5 Unfinished basement receptacles
Corrective Action Required
03/19/2018
GFCI PROTECTION. All 125-volt, single-phase, 15- and 20-ampere receptacles installed in unfinished basements shall have ground-fault circuit-interrupter protection for personnel. SEE RECEPTACLE OVERHEAD AT BASEMENT SOUTH.
E3902 RECEPTACLES
Resolved
03/23/2018
NEC 370-20; IRC E3806.5-6 SET-BACK OF ELECTRICAL RECEPTACLE / SWITCH BOXES: MUST BE FLUSH WITH COMBUSTIBLE WALL SURFACE. SEE RECEPT BOX ABOVE KITCHEN SINK 1/4" MAXIMUM SET-BACK @ NON-COMBUSTIBLE SURFACES. SEE RECEPT BOXES AT KITCHEN COUNTER BACKSPLASH.
Miscellaneous Correction
Resolved
03/23/2018
NEC 380-10; 410-56(f) / IRC E3901.10; E3902.6 SECURING OF ELECTRICAL RECEPTACLES / SWITCHES: SOME NOT SECURED SOLID TO BOX. ENSURE NONE ARE "SOFT" OR LOOSE SIDE-TO-SIDE. CHECK ALL AT SECOND FLOOR AND AT ATTIC/LOFT. USE YOKE SPACERS OR BOX EXTENDERS WHERE NEEDED.
Miscellaneous Correction
Resolved
03/23/2018
DESIGNATE THE TWO A/C CONDENSERS CIRCUITS AT ELECTRICAL SERVICE PANEL AND INSTALL BREAKERS COMPLIANT WITH MANUFACTURER LABELS ON CONDENSER UNITS. ONE IS 25A MAX; OTHER IS 30A MAX. CURRENTLY ONE BREAKER IS 60A.
Final Electrical Inspection - Residential Passed 3/26/2018 3/26/2018 at 8:10 AM 03/26/2018
E3802.5 Unfinished basement receptacles
Resolved
03/26/2018
GFCI PROTECTION. All 125-volt, single-phase, 15- and 20-ampere receptacles installed in unfinished basements shall have ground-fault circuit-interrupter protection for personnel. SEE RECEPTACLE OVERHEAD AT BASEMENT SOUTH.
Documents & Images
Date Uploaded File Type Document Name
11/14/2017 Receipt Receipt for transaction: 2017-007264
11/14/2017 Letter Codes Building Permit
11/14/2017 Scope of Work DOC111417-010
11/20/2017 Letter Inspection Summary
03/15/2018 Letter Inspection Summary
03/19/2018 Letter Inspection Summary
03/23/2018 Letter Inspection Summary
03/26/2018 Letter Inspection Summary
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home