Permit Application Status

PRRES20173361


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20173361
Building Permit - Residential
Certificate of Occupancy
KEVIN HIGDON CONSTRUCTION LLC
NEW SINGLE FAMILY
NEW HOUSE - COVERED DECK - UNFINISHED BASEMENT
10/09/2017
10/17/2017
04/04/2019
Locations
Contacts
KEVIN HIGDON CONSTRUCTION LLC, Address:PO BOX 847, Phone:(816) 524-9797  
KEVIN HIGDON CONSTRUCTION, LLC, Address:P O BOX 847, Phone:(816) 524-9797  
PRAIRIE CENTER PLUMBING HEATING & A/C, Address:242 N MARION, Phone:(913) 829-6263  
LUCAS ELECTRIC , Address:517 MARGARET LN, Phone:(816) 807-4432  
PRAIRIE CENTER PLUMBING HEATING & A/C, Address:242 N MARION, Phone:(913) 829-6263  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 10/11/2017 10/11/2017
Sue Pyles, P.E.
Residential Plan Review Approved 10/11/2017 10/09/2017
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,157.20 $1,157.20 Paid 10/17/2017
9110073-Right of Way Permit Fee $75.00 $75.00 Paid 10/17/2017
8331504-EFHB Middle Big Creek, Full $669.60 $669.60 Paid 10/17/2017
8331507-Sewer Connection Fee $600.00 $600.00 Paid 10/17/2017
8331401-Water Tap Fee $3,343.00 $3,343.00 Paid 10/17/2017
8350015-Water Meter Fee $431.83 $431.83 Paid 10/17/2017
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 10/26/2017 (11:30) 10/26/2017 at 12:20 PM 10/26/2017
Underslab Plumbing Inspection - Residential Passed 11/21/2017 11/21/2017 at 8:35 AM 11/21/2017
Sewer Service Inspection - R Passed 11/30/2017 (1:30) 11/30/2017 at 1:35 AM 11/30/2017
Water Service Inspection - R Partial 11/30/2017 at 1:40 AM 11/30/2017
Water Service Inspection - R Passed 12/4/2017 (10:30) 12/4/2017 at 10:55 AM 12/04/2017
Gas Service Inspection - Residential Not Ready 2/27/2018 2/27/2018 at 9:25 AM 02/27/2018
Misc
Corrective Action Required
02/27/2018
no electrical, gas pipe not bonded
Piers/Caissons Inspection - Residential Failed 3/21/2018 03/21/2018
Miscellaneous Correction
Corrective Action Required
03/21/2018
drawings not on site
Piers/Caissons Inspection - Residential Passed 3/21/2018 03/21/2018
Miscellaneous Correction
Corrective Action Required
03/21/2018
drawings not on site
Erosion Control Inspection Residential Failed 03/21/2018
Miscellaneous Correction
Corrective Action Required
03/21/2018
Street cleanup required
Erosion Control Inspection Residential Failed 03/21/2018
Erosion Control Inspection Residential Failed 3/28/2018 at 9:30 AM 03/28/2018
Corrective Action Required
03/28/2018
RESTORE EROSION CONTROL, INSTALL CONSTRUCTION ACCESS. INSPECTIONS DENIED UNTIL COMPLIANT
All Rough Inspection - Residential Not Ready 3/28/2018 3/28/2018 at 9:36 AM 03/28/2018
Corrective Action Required
03/28/2018
DENIED DUE TO EROSION CONTROL
All Rough Inspection - Residential Failed 4/2/2018 4/2/2018 at 11:00 AM 04/02/2018
Miscellaneous Correction
Corrective Action Required
04/02/2018
- Secure wardflex at fireplace. -support dwv throughout 48"o.c., support at mid span in stud bays.between floor levels . - fur out heat runs in at garagae wall. -firestop with 3/4" NOT loose insulation. -install garage door straps. -support roof over breakfast room.. -seal off 2 joist bays over garage from attic. - install header over front door. -missing studs at garage wall chase. -nail all joist hangers - fur down kitchen hood vent and firestop. -strap top plates at I beam kitchen wall. -Engineer or frame 2nd floor ceiling joist and rafters per plans. bearing on non-bearing walls. - frame roof over front bedroom per plans. -rafters over span rear bedroom , vaulted ceiling load on rafters. -protect romex ithing 6' of attic access. -over notched LVL hip rear bedroom. provide engineers report on max notch for bearing . -front bsmt josit span 15'10", varify joist span and grade of joist. -Low Psi gas line. - Missing beam post west of furnace. - triple 2x10 do not land on I beam west side of bsmt. - solid block all bearing points to beams. -support joist , landing , stairs. bsmt stair wall is not bearing .
Electrical Service Inspection Passed 3/28/2018 4/2/2018 at 12:10 PM 04/02/2018
Gas Service Inspection - Residential Failed 3/28/2018 4/2/2018 at 12:20 PM 04/02/2018
Misc
Corrective Action Required
02/27/2018
no electrical, gas pipe not bonded
All Rough Inspection - Residential Passed 4/5/2018 at 2:20 PM 04/05/2018
Miscellaneous Correction
Resolved
04/05/2018
- Secure wardflex at fireplace. -support dwv throughout 48"o.c., support at mid span in stud bays.between floor levels . - fur out heat runs in at garagae wall. -firestop with 3/4" NOT loose insulation. -install garage door straps. -support roof over breakfast room.. -seal off 2 joist bays over garage from attic. - install header over front door. -missing studs at garage wall chase. -nail all joist hangers - fur down kitchen hood vent and firestop. -strap top plates at I beam kitchen wall. -Engineer or frame 2nd floor ceiling joist and rafters per plans. bearing on non-bearing walls. - frame roof over front bedroom per plans. -rafters over span rear bedroom , vaulted ceiling load on rafters. -protect romex ithing 6' of attic access. -over notched LVL hip rear bedroom. provide engineers report on max notch for bearing . -front bsmt josit span 15'10", varify joist span and grade of joist. -Low Psi gas line. - Missing beam post west of furnace. - triple 2x10 do not land on I beam west side of bsmt. - solid block all bearing points to beams. -support joist , landing , stairs. bsmt stair wall is not bearing .
Gas Service Inspection - Residential Passed 4/5/2018 at 2:36 PM 04/05/2018
Misc
Resolved
04/05/2018
no electrical, gas pipe not bonded
Sidewalk Inspection Partial 4/20/2018 at 10:45 AM 04/20/2018
PW-Misc
Informational
04/20/2018
Tom Chandler 04/20/2018 10:47 AM Inspected forms and compacted aggregate only.
Driveway Inspection Partial 4/20/2018 at 11:00 AM 04/20/2018
Informational
04/20/2018
Tom Chandler 04/20/2018 11:01 AM Inspected forms and compacted aggregate only.
Sidewalk Inspection Passed 4/26/2018 at 9:05 AM 04/26/2018
PW-Misc
Informational
04/20/2018
Tom Chandler 04/20/2018 10:47 AM Inspected forms and compacted aggregate only.
PW-Misc
Informational
04/26/2018
Tom Chandler 04/26/2018 9:06 AM Sidewalk has been completed and passed final inspection.
Driveway Inspection Passed 4/26/2018 at 9:10 AM 04/26/2018
Informational
04/26/2018
Tom Chandler 04/26/2018 9:10 AM Driveway has been completed and passed final inspection.
Occupancy Inspection - Codes Residential Failed 3/12/2019 3/12/2019 at 11:00 AM 03/12/2019
Misc
Corrective Action Required
03/12/2019
-OBTAIN IRRIGATION PERMIT AND SUBMIT BACKFLOW TESTS TO WATER UTILITES -REPAIR SINK HOLE FRONT YARD -INSTALL SECOND LOCK REAR SLIDER DOOR
Plot Plan Inspection Passed 4/4/2019 04/04/2019
Occupancy Inspection - Codes Residential Full C of O 4/4/2019 4/4/2019 at 9:00 AM 04/04/2019
Misc
Resolved
04/04/2019
-OBTAIN IRRIGATION PERMIT AND SUBMIT BACKFLOW TESTS TO WATER UTILITES -REPAIR SINK HOLE FRONT YARD -INSTALL SECOND LOCK REAR SLIDER DOOR
Documents & Images
Date Uploaded File Type Document Name
10/17/2017 Receipt Receipt for transaction: 2017-006840
10/17/2017 Letter Codes Building Permit
10/17/2017 Plot Plan DOC101717-008
10/26/2017 Letter Inspection Summary
11/21/2017 Letter Inspection Summary
11/30/2017 Letter Inspection Summary
12/04/2017 Letter Inspection Summary
02/27/2018 Letter Inspection Summary
03/21/2018 Letter Inspection Summary
03/28/2018 Letter Inspection Summary
04/02/2018 Letter Inspection Summary
04/05/2018 Letter Inspection Summary
04/20/2018 Letter DE-Daily Inspection Summary
04/23/2018 DOC042318-04232018152838
04/23/2018 DOC042318-04232018152918
04/26/2018 Letter DE-Daily Inspection Summary
03/12/2019 Letter INSPECTION SUMMARY
04/04/2019 Letter INSPECTION SUMMARY
04/04/2019 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home